• Lineup includes three contact models with 2NC/1NO and
3NC contacts in addition to the 1NC/ 1NO, and 2NC version.
Version with MBB contacts meet applications for avdanced
requirements.
• M12-connector models are available, saving on labor and
simplifying maintenance.
• Standardized gold-clad contacts provide high contact reliability. Can be used with both standard loads and microloads.
• Free of lead, cadmium, and hexavalent chrome, reducing the
burden on the environment.
• Conforms to EN115 and EN81-1.
Be sure to read the “Safety Precautions” on page G-277.
Note: Contact your sales representative for details on models with safety standard
(See note 2.)
M20D4N-8A72RD4N-8B72RD4N-8C72RD4N-8D72R
D4N-7A62RD4N-7B62RD4N-7C62RD4N-7D62R
D4N-7A72RD4N-7B72RD4N-7C72RD4N-7D72R
2NC
(Slow-action)
2NC/1NO
(Slow-action)
3NC
(Slow-action)
Specifications
Standards and EC Directives
• Conforms to the following EC Directives:
Machinery Directive
Low Voltage Directive
EN50047
EN1088
GS-ET-15
Approved Standards
AgencyStandardFile No.
TÜV Product
Service
UL (See note.)UL508, CSA C22.2 No.14 E76675
Note: Approval for CSA C22.2 No. 14 is authorized by the UL mark.
CCC (China Compulsory Certification) Mark
AgencyStandardFile No.
CQCGB14048.5Under application
EN60947-5-1 (approved
direct opening)
B03 11 39656 061
Approved Standard Ratings
TÜV (EN60947-5-1)
Item
Rated operating current (I
Rated operating voltage (U
Note: Use a 10-A fuse type gI or gG that conforms to IEC269 as a short-circuit
protection device. This fuse is not built into the Switch.
Utilization
category
) 3 A0.27 A
e
e
UL/CSA (UL508, CSA C22.2 No. 14)
A300
Rated
voltage
120 VAC 10 A60 A6 A7,200 VA 720 VA
240 VAC30 A3 A
Carry currentCurrentVolt-amperes
Q300
Rated
voltage
125 VDC 2.5 A0.55 A0.55 A69 VA69 VA
250 VDC0.27 A0.27 A
Carry currentCurrentVolt-amperes
AC-15DC-13
) 240 V250 V
MakeBreakMakeBreak
MakeBreakMakeBreak
R
@
D4N-
G-269D4N-@R
Characteristics
Degree of protection (See note 3.)IP67 (EN60947-5-1)
Durability
(See note 4.)
Operating speed1 mm/s to 0.5 m/s (D4N-1A20R)
Operating frequency30 operations/minute max.
Contact resistance25 mΩ max.
Minimum applicable load (See note 6.)Resistive load of 1 mA at 5 VDC (N-level reference value)
Rated insulation voltage (U
Protection against electric shockClass II (double insulation)
Pollution degree (operating environment)Level 3 (EN60947-5-1)
Impulse withstand voltage (EN60947-5-1)Between terminals of the same polarity: 2.5 kV
Insulation resistance100 MΩ min.
Contact gapSnap-action: 2 x 0.5 mm min
Vibration resistance Malfunction10 to 55 Hz, 0.75-mm single amplitude
Shock resistanceDestruction
Conditional short-circuit current100 A (EN60947-5-1)
Rated open thermal current (I
Ambient temperatureOperating: −30° C to 70° C with no icing
Ambient humidityOperating: 95% max.
WeightApprox. 92 g (D4N-1A20R)
Note: 1. The above values are initial values.
2. Once a contact has been used to switch a standard load, it cannot be used for a load of a smaller capacity. Doing so may result in rough-
ening of the contact surface and contact reliability may be lost.
3. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are suffi-
cient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do
not use the D4N-@R in places where foreign material such as dust, dirt, oil, water, or chemicals may penetrate through the head. Otherwise, premature wear, Switch damage or malfunctioning may occur.
4. The durability is for an ambient temperature of 5° C to 35° C and an ambient humidity of 40% to 70%. For more details, consult your
OMRON representative.
5. If the ambient temperature is greater than 35° C, do not pass the 3-A, 250-VAC load through more than 2 circuits.
6. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the ac-
tual load beforehand.
Mechanical1,000,000 operations min.
Electrical500,000 operations min. for a resistive load of 3 A at 250 VAC (See note 5.)
)300 V
i
300,000 operations min. for a resistive load of 10 A at 250 VAC
Between terminals of different polarities: 4 kV
Between other terminals and uncharged metallic parts: 6 kV
Slow-action: 2 x 2 mm min
2
2
Malfunction
)10 A (EN60947-5-1)
th
1,000 m/s
300 m/s
G-270Safety Sensors / Components
Structure, Names, and Functions
Structure
Safety-oriented Lever Setting
Grooves which engage the lever are cut in the lever and
rotary shaft to prevent the lever from slipping against the
rotary shaft. The actuator locks (self-holding) when it
moves to the lock position.
Reset Head (Blue)
The direction of the reset head can be adjusted to any of
the four directions.
Built-in Switch
The built-in switch has a direct opening mechanism that
forcibly separates the NC contact even when there is
contact deposit.
Cover
The cover, with a hinge on its lower part, can be opened
by removing the screw of the cover, which ensures ease
of maintenance and wiring.
Head
With roller lever models, the direction of the
switch head can be adjusted to any of the four
directions by loosening the roller lever switch
screws at the four corners of the head.
Conduit
A wide variety of conduits is available.
SizeBox
1-conduit model
Pg13.5
G1/2
1/2-14NPT
M20
M12 connector
Note: M12 connector types are not available for
Switches with three contacts.
Contact Form
ModelContactContact formOperating patternRemarks
D4N-@A@R1NC/1NO
D4N-@B@R2NC
D4N-@C@R2NC/1NO
D4N-@D@R3NC
Zb
11
33
Zb
11
31
Zb
11
21
3334
Zb
11
21
3132
12
34
12
32
12
22
12
22
11-12
33-34
Stroke
11-12
31-32
Stroke
11-12
21-22
33-34
Stroke
11-12
21-22
31-32
Stroke
Only NC contacts 11-12 have an
approved direct opening
ON
mechanism.
The terminals 11-12 and 33-34
can be used as unlike poles.
Only NC contacts 11-12 and
31-32 have an approved
ON
direct opening mechanism.
The terminals 11-12 and 31-32
can be used as unlike poles.
Only NC contacts 11-12 and
21-22 have an approved
direct opening mechanism.
ON
The terminals 11-12, 21-22, and
33-34 can be used as unlike
poles.
Only NC contacts 11-12, 21-22,
and 31-32 have an approved direct opening mechanism.
ON
The terminals 11-12, 21-22, and
31-32 can be used as unlike
poles.
Yes
Yes
Yes
Yes
Yes
2-conduit model
Yes
Yes
Yes
Yes
---
R
@
D4N-
G-271D4N-@R