Omron D4NL DATASHEET

Guard Lock Safety-door Switch
D4NL
Lead-free, Environment-friendly Design
• Contains no harmful substances, such as lead or cad­mium, reducing the burden on the environment.
• Key holding force of 1,300 N min.
• Can be used for either standard loads or microloads.
• Lineup includes models with a conduit size of M20.
• IP67 degree of protection.
• Operation key compatible to D4DS, D4NS and D4GL.
Model Number Structure
Model Number Legend
Switch
D4NL-@@@@-@@@
4 5
123
1. Conduit Size
1: Pg13.5 2: G1/2 4: M20
2. Built-in Switch (with Door Open/Closed Detection Switch and
Lock Monitor Switch Contacts)
A: 1NC/1NO slow-action contacts plus 1NC/1NO slow-action
contacts
B: 1NC/1NO slow-action contacts plus 2NC slow-action con-
tacts
C: 2NC slow-action contacts plus 1NC/1NO slow-action con-
tacts D: 2NC slow-action contacts plus 2NC slow-action contacts E: 2NC/1NO slow-action contacts plus 1NC/1NO slow-action
contacts F: 2NC/1NO slow-action contacts plus 2NC slow-action con-
tacts G: 3NC slow-action contacts plus 1NC/1NO slow-action con-
tacts H: 3NC slow-action contacts plus 2NC slow-action contacts
3. Head Mounting Direction and Material
F: Four mounting directions possible (Front-side mounting at
time of delivery)/plastic D: Four mounting directions possible (Front-side mounting at
time of delivery)/metal
6
7
4. Door Lock and Release
A: Mechanical lock/24-VDC solenoid release B: Mechanical lock/110-VAC solenoid release C: Mechanical lock/230-VAC solenoid release G: 24-VDC solenoid lock/mechanical release H: 110-VAC solenoid lock/mechanical release J: 230-VAC solenoid lock/mechanical release
5. Indicator
B: 10 to 115 VAC/VDC (orange LED indicator) E: 100 - 230V VAC (orange neon lamp indicator)
6. Release Key Type
Blank:Standard 4: Special release key
7. Release Key Position
Blank:Bottom S: Front
Operation Key
D4DS-K@
1
1. Operation Key Type
1: Horizontal mounting 2: Vertical mounting 3: Adjustable mounting (horizontal) 5: Adjustable mounting (horizontal/vertical)
\
D4NL
G-153D4NL
Ordering Information
List of Models
For 110V and 230V version ask your local OMRON Representative
Switches (Operation Keys are sold separately.)
: Models with approved direct opening contacts. Prefered stock item*
Head
material
Plastic Bottom Standard Solenoid: 24 VDC
Release
key
position
Release
key type
Solenoid voltage/
indicator
Orange LED: 10 to 115 VAC /VD C
Lock and release types Contact configuration
Mechanical lock Solenoid release
Solenoid lock Mechanical release
(door open/closed
detection switch and lock
monitor switch contacts)
(slow-action)
Approved direct opening
NC contact
1NC/1NO+1NC/1NO Pg13.5
1NC/1NO+2NC Pg13.5
2NC+1NC/1NO Pg13.5
2NC+2NC Pg13.5
2NC/1NO+1NC/1NO Pg13.5
2NC/1NO+2NC Pg13.5
3NC+1NC/1NO Pg13.5
3NC+2NC Pg13.5
1NC/1NO+1NC/1NO Pg13.5
1NC/1NO+2NC Pg13.5
2NC+1NC/1NO Pg13.5
2NC+2NC Pg13.5
2NC/1NO+1NC/1NO Pg13.5
2NC/1NO+2NC Pg13.5
3NC+1NC/1NO Pg13.5
3NC+2NC Pg13.5
Conduit opening Model
G1/2
M20
G1/2 M20
G1/2
M20
G1/2 M20
G1/2
M20
G1/2 M20
G1/2 M20
G1/2 M20
G1/2
M20
G1/2 M20
G1/2
M20
G1/2 M20
G1/2
M20
G1/2 M20
G1/2 M20
G1/2 M20
D4NL-1AFA-B*
D4NL-2AFA-B
D4NL-4AFA-B*
D4NL-1BFA-B D4NL-2BFA-B D4NL-4BFA-B
D4NL-1CFA-B*
D4NL-2CFA-B
D4NL-4CFA-B*
D4NL-1DFA-B D4NL-2DFA-B D4NL-4DFA-B D4NL-1EFA-B D4NL-2EFA-B
D4NL-4EFA-B*
D4NL-1FFA-B D4NL-2FFA-B D4NL-4FFA-B D4NL-1GFA-B D4NL-2GFA-B D4NL-4GFA-B D4NL-1HFA-B D4NL-2HFA-B D4NL-4HFA-B
D4NL-1AFG-B*
D4NL-2AFG-B
D4NL-4AFG-B*
D4NL-1BFG-B D4NL-2BFG-B D4NL-4BFG-B
D4NL-1CFG-B*
D4NL-2CFG-B
D4NL-4CFG-B*
D4NL-1DFG-B D4NL-2DFG-B D4NL-4DFG-B D4NL-1EFG-B D4NL-2EFG-B
D4NL-4EFG-B*
D4NL-1FFG-B D4NL-2FFG-B D4NL-4FFG-B D4NL-1GFG-B D4NL-2GFG-B D4NL-4GFG-B D4NL-1HFG-B D4NL-2HFG-B D4NL-4HFG-B
G-154 Safety Sensors / Components
Operation Keys
Horizontal mounting
Type Model
D4DS-K1
Vertical mounting
Adjustable mounting (Horizontal)
Adjustable mounting (Horizontal/Vertical)
D4DS-K2
D4DS-K3
D4DS-K5
Specifications
Standards and EC Directives
Applicable EC Directives and Standards
Machinery Directive
Low Voltage Directive
EN1088
EN60204-1
GS-ET-19
Approved Standards
Agency Standard File No.
TÜV Product Service
UL (See note 2.) UL508, CSA C22.2 No.14 E76675
Note: 1. Consult your OMRON representative for details.
2. Approval for CSA C22.2 No. 14 is authorized by the UL
mark.
EN60947-5-1 (approved direct opening)
(See note 1.)
Approved Standard Ratings
TÜV (EN60947-5-1)
Utilization
Item Rated operating current (I
Rated operating voltage (U
Note: Use a 10-A fuse type gI or gG that conforms to IEC269 as a short-circuit
protection device. This fuse is not built into the Switch.
category
) 3 A 0.27 A
e
e
UL/CSA (UL508, CSA C22.2 No. 14) A300
Rated
voltage
120 VAC 10 A 60 A 6 A 7,200 VA 720 VA 240 VAC 30 A 3 A
Carry current Current Volt-amperes
Solenoid Coil Characteristics
Item 24 VDC 110 VAC 230 VAC
Rated operating voltage (100% ED)
Current consump­tion
Insulation Class F (130° C max.)
24 VDC +10%/
15% Approx.
200 mA
AC-15 DC-13
) 240 V 250 V
Make Break Make Break
110 VAC ±10% 230 VAC ±10%
Approx. 50 mA Approx. 30 mA
Indicator Characteristics
Item LED
Rated voltage 10 to 115 VAC/VDC Current leakage Approx. 1 mA Color (LED) Orange
D4NL
G-155D4NL
Characteristics
Degree of protection (see note 2) IP67 (EN60947-5-1)
Durability (see note 3)
Mechanical 1,000,000 operations min.
Electrical 500,000 operations min. for a resistive load of 3 A at 250 VAC (see note 4) Operating speed 0.05 to 0.5 m/s Operating frequency 30 operations/minute max. Rated frequency 50/60 Hz Contact gap 2 x 2 mm min Direct opening force (see note 5) 60 N min. (EN60947-5-1) Direct opening travel (see note 5) 10 mm min. (EN60947-5-1) Holding force (see note 6) 1,300 N min. Insulation resistance 100 M min. (at 500 VDC) Minimum applicable load (see note 7) Resistive load of 1 mA at 5 VDC (N-level reference value) Rated insulation voltage (Ui) 300 V (EN60947-5-1)
Rated open thermal current (Ith) 10 A (EN60947-5-1) Impulse withstand voltage (EN60947-5-1) Between terminals of the same polarity 2.5 kV
Conditional short-circuit current 100 A (EN60947-5-1) Pollution degree (operating environment) 3 (EN60947-5-1) Protection against electric shock Class II (double insulation) Contact resistance 25 m max. per contact (initial value) Vibration resis-
Malfunction 10 to 55 Hz, 0.75-mm single amplitude tance
Shock resistance Destruction
Malfunction Ambient temperature Operating:10° C to 55° C with no icing Ambient humidity Operating:95% max. Weight Approx. 370 g (D4NL-IAFA-B)
Note: 1. The above values are initial values.
2. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are suffi-
cient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do not use the D4NL in places where foreign material may penetrate through the key hole on the head, otherwise Switch damage or mal­functioning may occur.
3. The durability is for an ambient temperature of 5°C to 35° C and an ambient humidity of 40% to 70%. For more details, consult your OM-
RON representative.
4. If the ambient temperature is greater than 35° C, do not pass the 3-A, 250-VAC load through more than 2 circuits.
5. These figures are minimum requirements for safe operation.
6. This figure is based on the GS-ET-19 evaluation method.
7. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the actual
load beforehand.
(This applies for the Switch only. The degree of protection for the key hole is IP00.)
Between terminals of different polarities 4 kV Between other terminals and uncharged metallic parts 6 kV
1,000 m/s 300 m/s
2
min.
2
min. (100 m/s2 min. for the lock monitor switch)
G-156 Safety Sensors / Components
Connections
Indicator
Internal Circuit Diagram
10 to 115 VAC/VDC
Circuit Connection Example
Terminals 12 and 41 are connected internally and so connect termi-
nals 11 and 42 for safety-circuit input. (GS-ET-19)
Connect terminals 21 and 22 and terminals 51 and 52 in series
when using as safety-circuit input (redundancy circuit for terminals 11 and 12 and terminals 41 and 42 above). Connect the terminals individually when using as auxiliary-circuit input (e.g., terminals 21 and 22 for safety-door open/closed monitoring and terminals 51 and 52 for monitoring the lock status).
In the connection example on the right, terminals 21 and 22 and
terminals 51 and 52 are used as auxiliary-circuit input.
R
D
Z
R
Constant-current diode
51
LED
11
21
33
E1 (+)
Indicator (Orange)
O1 O2
12 41
42
52
22
34
E2 ()
Safety circuit
Auxiliary circuit
Auxiliary circuit
Auxiliary circuit
Direct opening contacts used as safety-circuit input are indicated
with the mark. Terminals 11 and 12 and terminals 21 and 22 are direct opening contacts.
Connect the indicators in parallel to the auxiliary circuits or termi-
nals E1 and E2. If an indicator is connected in parallel to a direct opening contact, when the indicator breaks, a short-circuit current will be generated, possibly resulting in an installation malfunction.
Do not switch standard loads for more than 2 circuits at the same
time. Otherwise, the level of insulation may decrease.
The 24-VDC solenoid has polarity. Be sure to connect terminals
with the correct polarity.
D4NL
G-157D4NL
Operation Method
Operation Principles
Mechanical lock models
Operation Key
Solenoid
Solenoid lock models
Operation Key
Plunger
OFF
Spring
Lock plate
OFF
Spring
Lock plate
Solenoid
OFF
When the Operation Key is inserted, it is locked by the lock spring. The door will stay locked even if there is a power interruption.
OFF
If the solenoid is OFF, the door will not be locked when the Operation Key is inserted. This means that the door can be opened and closed easily when replacing work­pieces or parts.
ON
The solenoid is released only when the lock is turned ON.
ON
The door is locked only when the solenoid is turned ON. This means that the door will be unlocked if there is a power interruption and so this model cannot be used in sys­tems that would maintain a hazardous state (e.g., systems requiring toxic gases, high temperatures, or gears that would continue to turn due to inertia).
Nomenclature
Structure
Operation key hole
Terminal 42
Terminal 41
Shorting pin (12-41)
Terminal 12
Terminal 11
Door open/closed detection switch
Terminal 21
Terminal 22 Terminal 31/33 Terminal 32/34
Release key
Note: Terminal numbers vary with the model.
Conduit opening (vertical)
Solenoid
Terminal E1 (+)
Terminal E2 () Terminal 01
Indicator
Terminal 02
Lock monitor switch
Conduit opening (horizontal)
Terminal 52/54
Terminal 51/53
The head can be mounted in 3 directions.
Standard Release Key
(Bottom View)
UNLOCK LOCK UNLOCK LOCK
Back-mounting is also possible.
Two conduits (horizontal and vertical)
Special release key
Special Release Key
(Bottom View)