Omron D4E-1A20N, D4E-2A21N, D4E-2A20N, D4E-1A21N, D4E-1B20N Datasheet

...
Page 1
Small Sealed Switch D4E-@NF-31
Limit
Switches
Small Sealed Switch
D4E-@N
Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E
• Protection cover protects the built-in switch from dust and oil. Plunger incorporates a tough seal cap that lasts for a long time.
• One touch connector eliminates need for tedious wiring opera­tions and reduces downtime for wiring and maintenance (mod­els with standard, easy-to-use screw terminals are also available).
• Minute load model with gold cladding is optimal for electronic control.
• Molded terminal types as well as molded terminal types with op­erating indicator lamps are available for screw terminal systems.
• No difference in mounting pitch and characteristics between D4E-@N and D4E models.
Model Number Structure
Model Number Legend
1. Rated Current
1: 5 A at 125 VAC
(1 A at 125 VAC/30 VDC for model with a connector)
2: 0.1 A at 125 VAC
(0.1 A at 125 VAC/30 VDC for model with a connector)
2. Actuator
A: Roller plunger B: Crossroller plunger C: Plunger D: Sealed roller plunger E: Sealed crossroller plunger F: Sealed plunger G: Roller lever H: One-way action roller lever
3. Terminals
00: AC connector 10: DC connector 20: Screw terminals without a cable 21: Screw terminals with a cable (right-hand) 22: Screw terminals with a cable (left-hand) 23: Molded terminals with a cable (right-hand) 24: Molded terminals with a cable (left-hand)
(Cable is S-FLEX VCTF 3 m)
4. Operation Indicator
L: Neon lamp (250 VAC) L1: LED (12 VDC) L2: LED (24 VDC) L3: LED (48 VDC)
Note: 1. Only the molded terminal models can be equipped with an
operation indicator.
2. Desired Switches may not be manufactured depending on
the combination between molds and indicators. Contact our sales representative for further information.
1 2 3 4
D4E-@@@@@N
Page 2
F-32 Small Sealed Switch D4E-@N
Ordering Information
List of Models
Note: 1. When ordering, specify the current type by replacing the blank box of the model number with 0 for AC connector or 1 for DC connector.
2. Approved by UL and CSA.
3. For the plunger and lever actuator models, the NC and NO terminal indicators are reversed.
4. Cold tolerance specifications are available for actuator models with an A, B, C, G, or H in the model number. When ordering, add C to
the model number. For example: D4E-1A20N D4E-1A20N-C
Accessories (Order Separately)
Plug
Actuator
One-touch connector type Screw terminal type General-
purpose
Micro load General-
purpose without
cable
Micro load
without cable
General-
purpose with
cable
Micro load with
cable
D4E-1A@0N D4E-2A@0N D4E-1A20N (see
note 2)
D4E-2A20N D4E-1A21N D4E-2A21N
D4E-1B@0N D4E-2B@0N D4E-1B20N (see
note 2)
D4E-2B20N D4E-1B21N D4E-2B21N
D4E-1C@0N D4E-2C@0N D4E-1C20N (see
note 2)
D4E-2C20N D4E-1C21N D4E-2C21N
D4E-1D@0N D4E-2D@0N D4E-1D20N (see
note 2)
D4E-2D20N D4E-1D21N D4E-2D21N
D4E-1E@0N D4E-2E@0N D4E-1E20N (see
note 2)
D4E-2E20N D4E-1E21N D4E-2E21N
D4E-1F@0N D4E-2F@0N D4E-1F20N (see
note 2)
D4E-2F20N D4E-1F21N D4E-2F21N
D4E-1G@0N D4E-2G@0N D4E-1G20N (see
note 2)
D4E-2G20N D4E-1G21N D4E-2G21N
D4E-1H@0N D4E-2H@0N D4E-1H20N (see
note 2)
D4E-2H20N D4E-1H21N D4E-2H21N
Roller plunger
Crossroller plunger
Plunger
Sealed roller plunger
Sealed crossroller plunger
Sealed plunger
Roller lever
One-way action roller lever
Model Current Type No. of conductors Cable length Applicable models
XS2F-A421-D90-A AC Straight 4 2 m D4E-@@00N XS2F-A421-G90-A 5 m XS2F-D421-D80A DC 2 m D4E-@@10N XS2F-D421-G80-A 5 m
Page 3
Small Sealed Switch D4E-@NF-33
Limit
Switches
Specifications
Approved Standards
Approved Standard Ratings
UL, CSA
A300
TÜV (EN60947-5-1)
Note: 1. @: Actuator variation of item II
2. AC-14 0.5 A/125 VAC means as follows:
Applicable category: AC-14 Rated operating current (I
e
): 0.5 A
Rated operating voltage (U
e
): 125 VAC
Agency Standard File No.
UL UL508 E76675 CSA CSA C22.2 No. 14 LR45746 TÜV Rheinland EN60947-5-1 R9551015
Voltage Carry current Current Volt-amperes
Make Break Make Break
120 V 10 A 60 A 6 A 7,200 VA 720 VA 240 V 30 A 3 A
Model Applicable category and ratings Thermal
current (I
the
)
Indicator
I II III IV
1 @ 00 AC-14 0.5 A/125 VAC 5 A --­1 @ 10 DC-12 0.5 A/30 VDC 5 A --­1 @ 20, 21, 22 AC-15 2A/250 VAC
DC-12 2A/48 VDC
5 A ---
1 @ 23, 24 L AC-15 2A/250 VAC 5 A Neon lamp 1 @ 23, 24 L1 DC-12 2A/12 VDC 5 A LED 1 @ 23, 24 L2 DC-12 2A/24 VDC 5 A LED 1 @ 23, 24 L3 DC-12 2A/48 VDC 5 A LED 2 @ 00 AC-14 0.1A/125 VAC 0.5 A --­2 @ 10 DC-12 0.1A/30 VDC 0.5 A --­2 @ 20, 21, 22 AC-14 0.1A/125 VAC
DC-12 0.1A/48 VDC
0.5 A ---
2 @ 23, 24 L AC-14 0.1A/125 VAC 0.5 A Neon lamp 2 @ 23, 24 L1 DC-12 0.1A/12 VDC 0.5 A LED 2 @ 23, 24 L2 DC-12 0.1A/24 VDC 0.5 A LED 2 @ 23, 24 L3 DC-12 0.1A/48 VDC 0.5 A LED
I II III IV
D4E-
1 G 23 L N
Page 4
F-34 Small Sealed Switch D4E-@N
Ratings
Note: 1. The above current ratings are for a standard current and the values in parentheses are for models with a connector.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
Characteristics
Note: 1. The above values are initial values.
2. The above ratings may vary depending on the model. Contact your OMRON representative for further details.
3. Durability values are calculated at an operating temperature of 5°C to 35°C, and an operating humidity of 40% to 70%. Contact your
OMRON sales representative for more detailed information on other operating environments.
Rated voltage General-purpose Micro load
Non-inductive load Inductive load Non-inductive load
Resistive load Lamp load Inductive load Motor load Resistive load
NC NO NC NO NC NO NC NO NC NO
125 VAC 5 (1) A 1.5 (1) A 3 (1) A 2 (1) A 1 (1) A 0.1 A 250 VAC 5 (1) A 1.5 (1) A 3 (1) A 1 A 0.5 A --­8 VDC 5 (1) A --- 1.5 (1) A --- 0.1 A 14 VDC 5 (1) A --- 1.5 (1) A --- 0.1 A 30 VDC 5 (1) A --- 1.5 (1) A --- 0.1 A 125 VDC 0.5 A --- 0.05 A --- --­250 VDC 0.25 A --- 0.03 A --- ---
Inrush current NC 10 A max.
NO 10 A max.
Degree of protection IP67 Durability (see note 3) Mechanical: 10,000,000 operations min.
Electrical: 500,000 operations min. (5 A at 250 VAC, resistive load)
5,000,000 operations min. (10 mA at 24 VDC, resistive load)
Operating speed 0.1 mm to 0.5 m/sec Operating frequency Mechanical: 120 operations/min
Electrical: 30 operations/min
Rated frequency 50/60 Hz Insulation resistance 100 M min. (at 500 VDC) Contact resistance 15 m max. (initial value) Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between terminals of same polarity
1,500 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1) between current-carrying metal parts and ground, and between each terminal and non-current-carrying metal part
Rated insulation voltage (Ui) 250 VAC Switching overvoltage 1,000 VAC max. (EN60947-5-1) Pollution degree
(operating environment)
3 (EN60947-5-1)
Short-circuit protective device (SCPD) 10 A fuse (type gG or gI, IEC269 approved) Conditional short-circuit current 100 A (EN60947-5-1) Conventional enclosed thermal current
(I
the
)
5 A (EN60947-5-1)
Protection against electric shock Class II (grounding not required with double insulation) Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm double amplitude Shock resistance
Destruction: 1,000 m/s
2
min.
Malfunction: 300 m/s
2
min.
Ambient temperature Operating: –10°C to 80°C (with no icing) Ambient humidity Operating: 95% max. Weight Approx. 86 g (in case of roller plunger)
Page 5
Small Sealed Switch D4E-@NF-35
Limit
Switches
Operating Characteristics
Note: The values given in parentheses are reference values.
Contact Form
Engineering Data
Electrical Durability (cosφ=1)
Model D4E-1A@@N
D4E-2A@@N
D4E-1B@@N D4E-2B@@N
D4E-1C@@N D4E-2C@@N
D4E-1D@@N D4E-2D@@N
D4E-1E@@N D4E-2E@@N
OF max. 11.77 N 11.77 N 11.77 N 11.77 N 11.77 N RF min. 4.90 N 4.90 N 4.90 N 4.90 N 4.90 N PT max. 1.5 mm 1.5 mm 1.5 mm 1.5 mm 1.5 mm OT min. 3 mm 3 mm 3 mm 3 mm 3 mm MD (reference
value)
(0.1 mm) (0.1 mm) (0.1 mm) (0.1 mm) (0.1 mm)
OP 31.4±0.8 mm 31.4±0.8 mm 25.4±0.8 mm 41.3±0.8 mm 41.3±0.8 mm
Model D4E-1F@@N
D4E-2F@@N
D4E-1G@@N D4E-2G@@N
D4E-1H@@N D4E-2H@@N
OF max. 11.77 N 3.92 N 3.92 N RF min. 4.90 N 0.78 N 0.78 N PT max. 1.5 mm 2 mm 2 mm OT min. 3 mm 4 mm 4 mm MD (reference
value)
(0.1 mm) (0.3 mm) (0.3 mm)
OP 30±0.8 mm 23.1±0.8 mm 34.3±0.8 mm
AC
DC
COM NO NC COM NC NO
COM
NO
NC
2
3
4
1
COM
2
3
4
1
NO
NC
(COM) 1
2 (NC)
4 (NO)
(COM) 1
2 (NC)
4 (NO)
Screw Terminal Type
Lever
Connector Type
Plunger
EN60947-5-1EN60947-5-1
250 VAC
Durability (x10
4
operations)
Switching current (A
)
Operating temperature: 5°C to 30°C Operating humidity: 40% to 70%.
Operating frequency: 30 operations/min (cosφ= 1)
Page 6
F-36 Small Sealed Switch D4E-@N
Nomenclature
Bearing
Built-in Switch
Die-cast Case
Movable Plunger
Rubber Cap (NBR)
Seal Packing (NBR)
Terminal Protection Cover
Screw Terminal
Wiring Ease
Rubber cap provides a tight seal and ensures a long service life and smooth reset at low temperatures.
Seal packing withstands a pressure of 186 kPa (D4E's seal packing with­stands a pressure of 98 kPa).
D4E-@N has a wide wiring space of 10 mm horizontally (D4E has a space of 7.5 mm horizontally).
Screw terminal incorporates a M3 screw with a toothed washer.
The actuator strength has been increased to 4,903 N (D4E: 294 N) in order to prevent faulty resetting of the bearing, which may occur when the roller is pressed with excessive force.
Switch cover ensures high insulation between the terminals and die-cast. Double insulation means that grounding is unnecessary. Meets UL, CSA, and EN standards. Prevents the movable piece from being pushed in too far, and thereby contributes to a longer service life.
Zinc die-cast case is anti-corrosive and tough.
Wired made easier using (D4CC-type) plug-in connector.
Page 7
Small Sealed Switch D4E-@NF-37
Limit
Switches
Dimensions
Note: 1. All units are in millimeters unless otherwise indicated.
2. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
3. A 3-m lead wire cable equivalent to the 3-conductor VCTF S-FLEX cable (0.75 mm
2
, 7 mm in dia.) is provided.
4. A 5.8- to 7.6-dia. cable can be applied to the seal rubber for the lead wire outlet.
(46)
3.5
6.5
0.5
10
8
28.4
21.5
4.5
(57)
18
PT
OP
33±0.15
M14 x 1
10
4.2
+0.2
0
PT
OP
M12 x 1
M14 x 1
33±0.15
(46)
3.5 6.5
0.5
10
8
28.4
21.5
4.5
(60)
18
10
4.2
+0.2
0
(46)
3.5
6.5
0.5
10
8
28.4
21.5
4.5
(60)
18
PT
OP
33±0.15
M14 x 1
M12 x 1
10
4.2
+0.2
0
M14 x 1
18
33±0.15
PT
OP
3.5
10
8
4.5
21.5
28.4
10
(46)
6.5
0.5
(57)
4.2
+0.2
0
4.7 holes
16 dia.
4.7 holes
Roller Plunger
4.7 holes
16 dia.
4.7 hole
Roller Plunger
Cross Roller Plunger
Cross Roller Plunger
D4E-1A00N D4E-1A10N D4E-2A00N D4E-2A10N
D4E-1A20N (See note 4.) D4E-2A20N (See note 4.) D4E-1A21N (See note 3.) D4E-2A21N (See note 3.)
0
4.2
+0.2
dia.
holes
Two, panel mounting nut
2.5 mm thickness, 17 mm width across flats
11 dia. x 4.7 stainless sintered alloy roller
0
4.2
+0.2
dia.
holes
Two, panel mounting nut
2.5 mm thickness, 17 mm width across flats
11 dia. x 4.7 stainless sintered alloy roller
D4E-1B00N D4E-1B10N D4E-2B00N D4E-2B10N
D4E-1B20N D4E-2B20N D4E-1B21N D4E-2B21N
0
4.2
+0.2
dia.
holes
Two, panel mounting nut
2.5 mm thickness, 17 mm width across flats
11 dia. x 4.7 stainless sintered alloy roller
0
4.2
+0.2
dia.
holes
Two, panel mounting nut
2.5 mm thickness, 17 mm width across flats
11 dia. x 4.7 stainless sintered alloy roller
Page 8
F-38 Small Sealed Switch D4E-@N
18
3.5
6.5
0.5
OP
PT
33±0.15
28.4
(57)
21.5
4.5
(46)
10
4.2
+0.2
0
(46)
3.5
6.5
21.5
4.5
28.4
(60)
18
OP
PT
33±0.15
10
M12 x 1
0.5
4.2
+0.2
0
(46)
3.5
10
8
21.5
28.4
4.5
6.5
33±0.15
(57)
PT
OP
M14 x 1
18
10
4.2
+0.2
0
4.2
+0.2
0
M14 x 1
M12 x 1
PT
33±0.15
21.5
28.4
OP
4.5
8
10
(60)
10
3.5
(46)
6.5
0.5
18
16 dia.
Sealed rubber
4.7 holes
4.7 holes
Sealed rubber
4.2
+0.2
dia.
0
0.5 long hole center
4.7 holes
4.7 hole
Plunger
Plunger
Sealed Roller Plunger
Sealed Roller Plunger
D4E-1C00N D4E-1C10N D4E-2C00N D4E-2C10N
D4E-1C20N (See note 4.) D4E-2C20N (See note 4.) D4E-1C21N (See note 3.) D4E-2C21N (See note 3.)
D4E-1D00N D4E-1D10N D4E-2D00N D4E-2D10N
D4E-1D20N (See note 4.) D4E-2D20N (See note 4.) D4E-1D21N (See note 3.) D4E-2D21N (See note 3.)
0
4.2
+0.2
dia.
holes
Two, panel mounting nut
2.5 mm thickness, 17 mm width across flats
7.8 dia. stainless steel plunger
0
4.2
+0.2
dia.
holes
Two, panel mounting nut
2.5 mm thickness, 17 mm width across flats
7.8 dia. stainless steel plunger
11 dia. x 4.7 stainless sintered alloy roller
0
4.2
+0.2
dia.
holes
11 dia. x 4.7 stainless sintered alloy roller
Page 9
Small Sealed Switch D4E-@NF-39
Limit
Switches
(46)
3.5
6.5
0.5
21.5
4.5
28.4
(57)
18
10
PT
4.2
+0.2
0
OP
(46)
3.5
6.5
21.5
4.5
28.4
(60)
18
OP
PT
10
M12 x 1
0.5
4.2
+0.2
0
(46)
3.5
6.5
0.5
21.5
4.5
28.4
(57)
18
OP
PT
10
4.2
+0.2
0
33±0.15
(46)
3.5
6.5
21.5
4.5
28.4
(60)
18
OP
PT
33±0.15
10
M12 x 1
0.5
4.2
+0.2
0
33±0.15
33±0.15
4.7 holes
Sealed rubber
4.7 holes
Sealed rubber
4.7 holes
Sealed rubber
4.7 holes
Sealed rubber
Sealed Cross Roller Plunger
Sealed Cross Roller Plunger
Sealed Plunger
Sealed Plunger
D4E-1E00N D4E-1E10N D4E-2E00N D4E-2E10N
D4E-1E20N (See note 4.) D4E-2E20N (See note 4.) D4E-1E21N (See note 3.) D4E-2E21N (See note 3.)
D4E-1F00N D4E-1F10N D4E-2F00N D4E-2F10N
D4E-1F20N (See note 4.) D4E-2F20N (See note 4.) D4E-1F21N (See note 3.) D4E-2F21N (See note 3.)
0
4.2
+0.2
dia.
holes
11 dia. x 4.7 stainless sintered alloy roller
0
4.2
+0.2
dia.
holes
11 dia. x 4.7 stainless sintered alloy roller
0
4.2
+0.2
dia.
holes
7.8 dia. stainless steel plunger
0
4.2
+0.2
dia.
holes
7.8 dia. stainless steel plunger
Page 10
F-40 Small Sealed Switch D4E-@N
6.5
(57)
18
15
21.5
28.4
0.5
28R
PT
OP
(46)
4.2
+0.2
0
3.5
33±0.15
3.5
6.5
(60)
18
15
21.5
28.4
28R
0.5
(46)
PT
OP
M12 x 1
33±0.15
4.2
+0.2
0
(46)
3.5
15
21.5
28.4
6.5
(60)
18
PT
OP
0.5
23R
33±0.15
M12 x 1
3.5 6.5
(57)
18
15
21.5
28.4
23R
0.5
PT
OP
33±0.15
(46)
4.2
+0.2
0
4.2
+0.2
0
19.4
19.4
19.4
19.4
12
12
12
16 dia.
4.7 holes
4.7 holes
Roller Lever
Roller Lever
4.7 holes
16 dia.
4.7 holes
One-way Action Roller Lever
One-way Action Roller Lever
Operating direction
Operating direction
D4E-1G00N D4E-1G10N D4E-2G00N D4E-2G10N
D4E-1G20N (See note 4.) D4E-2G20N (See note 4.) D4E-1G21N (See note 3.) D4E-2G21N (See note 3.)
D4E-1H00N D4E-1H10N D4E-2H00N D4E-2H10N
D4E-1H20N (See note 4.) D4E-2H20N (See note 4.) D4E-1H21N (See note 3.) D4E-2H21N (See note 3.)
0
4.2
+0.2
dia.
holes
9.5 dia. x 4.8 stainless sintered alloy roller
0
4.2
+0.2
dia.
holes
9.5 dia. x 4.8 stainless sintered alloy roller
0
4.2
+0.2
dia.
holes
9.5 dia. x 4.8 stainless sintered alloy roller
0
4.2
+0.2
dia.
holes
9.5 dia. x 4.8 stainless sintered alloy roller
Page 11
Small Sealed Switch D4E-@NF-41
Limit
Switches
Molded Terminal Models
Molded Terminal Models
The molded-terminal model is available with right-hand, left-hand and underside leads and is recommended for use where the Switch is exposed to dust, oil or moisture. It can be used like a screw-terminal model (with a cable), and the dimensions and operating characteristics are the same as for standard models.
Example:
Standard type: D4E-1A20N Location of lead output: Right-hand → D4E-1A23N
Suffix by Location of Lead Outlet
Lead Supplies
Comparison between Old and New Mold Terminal Models
The D4E-N and D4E are different from each other in terminal specifi­cations.
Operation of Indicator-equipped Models
The molded terminal model may be equipped with an operation indicator (neon lamp or LED) upon request to facilitate maintenance and inspection. The operation indicator is designed to illuminate when the Switch is not operating. (Because of the molded terminal model, any change to the
Switch wiring cannot be made.)
AC Operation
A neon lamp indicator is provided. The operating voltage is 90 to 250 VAC.
There is no difference in operating characteristics between D4E AC Models and corresponding D4E Standard Models.
There is no difference in dimensions between D4E AC Models and D4E Standard Models.
Example:
Basic type: D4E-1A23N When placing your order for the molded terminal model with an neon lamp operation indicator, specify the model number as D4E-1A23LN.
Internal Circuit
(2) (1)
Location of lead output Suffix for pre-wired terminal
COM, NC, NO
(1) Right-hand D4E-@@23N (2) Left-hand D4E-@@24N
Leads Nominal
cross-sectional area
Finished outside diameter Terminal connections Standard length
V.C.T.F. S-FLEX (vinyl cabtire coat)
0.75 mm
2
3 conductors Black: COM
White: NO Red: NC
3 m
7 mm dia.
Location of lead output D4E-N D4E
Right-hand D4E-@@23N D4E-@@21 Left-hand D4E-@@24N D4E-@@23 Underside --- D4E-@@22
Neon lamp
Terminal protection cover (transparent)
Power supply
Built-in switch
Load
Neon lamp R = 240 k
Page 12
F-42 Small Sealed Switch D4E-@N
DC Operation
LED indicator is provided. As a rectifier stack is incorporated, into the unit and no directionality exists for connection of + and –, this type can also be operated on AC.
Voltage ratings of LED indicators are as shown in the table below.
Internal Circuit
Note: *An external 24VDC power supply can be used, eg. OMRON
S8VS.
Example:
When ordering a D4E DC Model, add the following suffix to the model number.
Basic Model: The model number of the D4E-1A23N with a built-in
12-V LED indicator is D4E-1A23L1N.
Typ e Voltag e
rating
Lamp current Internal
resistance
L1 12 V Approx. 2.4 mA 4.3 k L2 24 V Approx. 1.2 mA 18 k L3 48 V Approx. 2.1 mA 22 k
Power supply*
Built-in switch
Load
Resistance
LED
Page 13
Small Sealed Switch D4E-@NF-43
Limit
Switches
Precautions
Refer to the Technical Information for Limit Switches (Cat. No. C121).
Correct Use
Do not solder the screw terminals. Sealing materials may deteriorate when used outdoors or when
exposed to cutting oil, solvents, or chemicals. Check this on actual equipment and, if deterioration is foreseen, consult your OMRON representative in advance.
If the one-touch connector is to be mounted onto the switch body, lightly push up the fitting so that the switch body can then be inserted into the clamp.
Be sure that the clamp is inserted to the full depth, because the Switch will not function properly if one of the clamps is improperly inserted.
If the clamp is properly inserted up to the full depth, it will not slide out easily. Be sure to carefully confirm all the above items.
Be sure to connect a fuse with a breaking current 1.5 to 2 times the rated current to the Limit Switch in series in order to protect the Limit Switch from damage due to short-circuiting. When using the Limit under the EN ratings, use a gI or gG 10-A fuse that conforms to IEC260.
Mounting
Secure the Switch with two M4 screws and washers. The tightening torque applied to each terminal must be 1.18 to 1.37 N·m. Tighten the screws to the specified torque. An excessive tightening torque may damage the Switch and cause a malfunction.
Mounting Holes
When mounting the panel mount-type Switch with screws on a side surface, remove the hexagonal nuts from the actuator.
When mounting the panel mount type on a panel, tighten the hexag­onal nuts of the actuator to a torque less than 7.85 N·m.
Mounting Hole
Operating method, shape of cam or dog, operating frequency, and the overtravel (OT) have significant effect on the service life and pre­cision of the Limit Switch. Make sure that the shape of the cam is smooth enough.
Check that OT has a sufficient margin. The actual OT should be rated OT x 0.7 to 1.
Do not change the operating position by remodeling the actuator.
Wiring
When wiring screw terminals, M3-size round solderless terminals with an insulation tube is recommended. The conductor size should be 0.75 mm
2
and cable diameter should be 7 mm.
Refer to the following when wiring.
dz dia.: 3.2
D dia.: 1.9 B: 5.2 L: 16.4 F: 5.8 l: 8.0 (mm)
Insert the switch body
Lightly push up the filling on the left and right side alternately.
Switch body
Clamp fitting
Confirm visually
33±0.15
Two, 4.3 dia. or M4 hole
14.5
±0.2 dia.
D dia.
d
z dia.
D4E-N
Round solderless terminal
Wiring Method
Page 14
F-44 Small Sealed Switch D4E-@N
Tightening Torque
A loose screw may result in a malfunction. Be sure to tighten each screw to the proper tightening torque as shown below.
No. Type Torque
1 Terminal screw (M3) 0.24 to 0.44 N·m 2 Switch mounting screw (M4) 1.18 to 1.37 N·m
2
1
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. C028-E1-05
Loading...