F-34 Small Sealed Switch D4E-@N
■ Ratings
Note: 1. The above current ratings are for a standard current and the values in parentheses are for models with a connector.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
■ Characteristics
Note: 1. The above values are initial values.
2. The above ratings may vary depending on the model. Contact your OMRON representative for further details.
3. Durability values are calculated at an operating temperature of 5°C to 35°C, and an operating humidity of 40% to 70%. Contact your
OMRON sales representative for more detailed information on other operating environments.
Rated voltage General-purpose Micro load
Non-inductive load Inductive load Non-inductive load
Resistive load Lamp load Inductive load Motor load Resistive load
NC NO NC NO NC NO NC NO NC NO
125 VAC 5 (1) A 1.5 (1) A 3 (1) A 2 (1) A 1 (1) A 0.1 A
250 VAC 5 (1) A 1.5 (1) A 3 (1) A 1 A 0.5 A --8 VDC 5 (1) A --- 1.5 (1) A --- 0.1 A
14 VDC 5 (1) A --- 1.5 (1) A --- 0.1 A
30 VDC 5 (1) A --- 1.5 (1) A --- 0.1 A
125 VDC 0.5 A --- 0.05 A --- --250 VDC 0.25 A --- 0.03 A --- ---
Inrush current NC 10 A max.
NO 10 A max.
Degree of protection IP67
Durability (see note 3) Mechanical: 10,000,000 operations min.
Electrical: 500,000 operations min. (5 A at 250 VAC, resistive load)
5,000,000 operations min. (10 mA at 24 VDC, resistive load)
Operating speed 0.1 mm to 0.5 m/sec
Operating frequency Mechanical: 120 operations/min
Electrical: 30 operations/min
Rated frequency 50/60 Hz
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance 15 mΩ max. (initial value)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between terminals of same polarity
1,500 VAC, 50/60 Hz for 1 min/Uimp at 2.5 kV (EN60947-5-1) between current-carrying metal parts
and ground, and between each terminal and non-current-carrying metal part
Rated insulation voltage (Ui) 250 VAC
Switching overvoltage 1,000 VAC max. (EN60947-5-1)
Pollution degree
(operating environment)
3 (EN60947-5-1)
Short-circuit protective device (SCPD) 10 A fuse (type gG or gI, IEC269 approved)
Conditional short-circuit current 100 A (EN60947-5-1)
Conventional enclosed thermal current
(I
the
)
5 A (EN60947-5-1)
Protection against electric shock Class II (grounding not required with double insulation)
Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Destruction: 1,000 m/s
2
min.
Malfunction: 300 m/s
2
min.
Ambient temperature Operating: –10°C to 80°C (with no icing)
Ambient humidity Operating: 95% max.
Weight Approx. 86 g (in case of roller plunger)