2Miniature Limit Switch D4CC
Special Mounting Plate
It is possible to replace an WL Limit Switch with a D4CC Limit Switch
mounted on this plate without changing the position of the dog or
cam.
The following is the conversion table:
WLD4CPlate model
Top plunger:
WLD
Top roller plunger:
WLD2
Roller lever:
WLG2
Example
DogDog
Plunger: D4CC-@001D4C-P001
Roller plunger:
D4CC-@002
Roller lever:
D4CC-@024
D4C-P002
D4C-P020
Mounting
plate
Remarks
There is no difference in mounting pitch between the Mounting P la te
and the WL. The mounting depth of the D4CC with the Mounting
Plate attached is, however, shorter than that of the panel-mounted
WL.
Plate
Specifications
■Approved S tandards■Approved Standard Ratings
AgencyStandardFile No.
ULUL508E76675
CSACSA C22.2 No. 14LR45746
■Ratings
Rated voltageNon-inductive loadInductive load
Resistive loadLamp loadInductive loadMotor load
NCNONCNONCNONCNO
125 VAC1 A1 A1 A0.7 A1 A1 A1 A1 A
30 VDC1 A1 A1 A1 A1 A1 A1 A1 A
Note: 1. The above current ratings are for steady-state current.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).
3. Lamp loads have an inrush current of 10 times the steady-state current.
4. Motor loads have an inrush current of 6 times the steady-state current.
UL-CSA
D4CC-1, D4CC-2
D150
Rated
voltage
120 VAC 1.0 A3.6 A0.6 A432 VA72 VA
Carry
current
CurrentVolt-amperes
MakeBreakMakeBreak
D4CC-3, D4CC-4, 1 A at 30 VDC
Inrush currentNC5 A max.
NO2.5 A max.
Miniature Limit SwitchD4CC3
■Characteristics
Degree of protectionIP67
Durability (see note 2)Mechanical: 10,000,000 operations min.
Operating speedPlunger:0.1 mm to 0.5 m/s
Operating frequencyMechanical: 120 operations/min
Rated frequency50/60 Hz
Insulation resistance100 M
Contact resistance (initial)100 m
Dielectric strength1,000 VAC, 50/60 Hz for 1 min between terminals of same polarity
Vibration resistanceMalfunction: 10 to 55 Hz, 1.5-mm double amplitude (see note 3)
Shock resistance
Ambient temperatureOperating: –10
Ambient humidityOperating: 95% max.
WeightApprox. 120 g (in the case of D4CC-1002)
Note: 1. The above figures are initial values.
2. The values are calculated at an operating temperature of 5
sales representative for more detailed information on other operating environments.
3. Excluding plastic rod models.
Leakage Current (for Switches with Indicators)
The leakage current and resistance of Switches with indicators are as follows:
ItemD4CC-2@@@D4CC-4@@@
Voltage125 VAC30 VDC
Leakage current1.0 mA1.0 mA
Resistive value150 k
Electrical:200,000 operations min. (1 A at 125 VAC, resistive load)
Roller lever: 1 mm to 1 m/s
Electrical:30 operations/min
Ω min. (at 500 VDC)
Ω max.
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between each
terminal and non-current-carrying metal par t
Destruction: 1,000 m/s
Malfunction: 500 m/s
Ω30 kΩ
2
min.
2
min.
°C to 70°C (with no icing)
°C to 35°C, and an operating humidity of 40% to 70%. Contact your OMRON