Omron D4BL DATASHEET

Guard Lock Safety-door Switch
D4BL
Protective Doors Are Locked Until Machines Completely Stop Operating
• A mechanical lock is applied automatically when the Operation Key is inserted. A high level of safety is achieved using a mechanism where the lock is only released when voltage is applied to the solenoid.
• Conforms to EN (TÜV) standards corresponding to the CE marking.
• Approved by UL, CSA, BIA, and SUVA standards.
• The switch contact is opened by a direct opening mechanism (NC contacts only) when the protective cover is opened. Direct opening mechanism that is EN-approved is indicated by on the switch.
• Auxiliary release key ensures easy maintenance and unlocks the door in the case of a power failure.
• Tough aluminum die-cast body incorporating a switch box with degree of protection satisfying IP67, UL, and CSA TYPE6P, 13.
• Equipped with a horizontal and vertical conduit opening.
• Models incorporating easy-to-see indicators for monitoring and those using an adjustable Operation Key for a double door are available.
• The mounting direction of the head can be changed to allow the Operation Key to be inserted from four directions.
• Metric conduit types available
Model Number Structure
Model Number Legend
Switch
D4BL - -
1234 5
1. Conduit Size (2-conduit)
1: PG13.5 2: G1/2 3: 1/2-14NPT 4: M20
2. Built-in Switch (with Safety Switch and Lock Monitor Switch Contacts)
C: 1NC/1NO (slow-action) + 1NC (slow-action) D: 2NC (slow-action) + 1NC (slow-action)
3. Head Mounting Direction
R: Four mounting directions possible (right-side mounting at
shipping)
Operation Key (Order Separately)
D4BL - K
1
1. Operation Key Type
1: Horizontal mounting 2: Vertical mounting 3: Adjustable mounting (Horizontal)
4. Door Lock and Release (Auxiliary Release Key is Incorporated by All Models)
A: Mechanical lock/24-VDC solenoid release B: Mechanical lock/110-VAC solenoid release G: 24-VDC Solenoid lock/Mechanical release
5. Indicator
Blank: Without indicator A: 10 to 115 VAC or VDC driving (with orange
and green LED indicator unit)
D4BL
G-185F3SL
Ordering Information
List of Models
Switches
Lock
method
Mechanical lock
Solenoid lock
Prefered model
Conduit
size
PG13.5
G1/2
M20
Pg 13.5 24 VDC D4BL-1CRG G1/2 24 VDC D4BL-2CRG D4BL-2CRG-A D4BL-2DRG D4BL-2DRG-A M20 24 VDC D4BL-4CRG-A
Operation Keys (Order Separately)
Mounting type Model
Horizontal mounting
Voltage
for
solenoid 24 VDC D4BL-1CRA 110 VAC D4BL-1CRB D4BL-1CRB-A D4BL-1DRB D4BL-1DRB-A 24 VDC D4BL-2CRA D4BL-2CRA-A D4BL-2DRA D4BL-2DRA-A 110 VAC D4BL-2CRB D4BL-2CRB-A D4BL-2DRB D4BL-2DRB-A 24 VDC 110 VAC D4BL-4CRB D4BL-4CRB-A
D4BL-K1
Without indicator
1NC/1NO+ 1NC
(Slow-action)
D4BL-4CRA D4BL-4CRA-A D4BL-4DRA D4BL-4DRA-A
With LED indicator
1NC/1NO+ 1NC
(Slow-action)
D4BL-1CRA-A D4BL-1DRA D4BL-1DRA-A
D4BL-1CRG-A D4BL-1DRG D4BL-1DRG-A
Without indicator
2NC+ 1NC
(Slow-action)
With LED indicator
2NC+ 1NC
(Slow-action)
Vertical mounting
D4BL-K2
Adjustable mounting (Horizontal)
D4BL-K3
Specifications
Approved Standards Standards and EC Directives
Agency Standard File No.
R9451050
TÜV Rheinland EN60947-5-1
BIA GS-ET-19
SUVA SUVA E6186/2.d UL UL508 E76675 CSA CSA C22.2, No.14 LR45746
(Direct opening: approved)
Mechanical lock: 9402293 Solenoid lock: 1998 20462-01
Conforms to the following EC Directives: Machinery Directive Low Voltage Directive EN1088
G-186 Safety Sensors / Components
Approved Standard Ratings
TÜV (EN60947-5-1)
Item Standard model Indicator model Utilization category AC-15 AC-15 Rated operating current (Ie) 3 A 6 A Rated operating voltage (Ue) 250 V 115 V
Use a 10-A fuse type gI or gG that conforms to IEC269 as a short-circuit protection device.
UL/CSA (UL508, CSA C22.2 No. 14)
A300
Rated voltage Carry current
120 VAC 240 VAC
Note: The UL/CSA approved rating for products with indicators (-A) is 6 A/115 VAC.
10 A
Make Break Make Break 60 A 6 A 30 A 3 A
Characteristics
Degree of protection IP67 (See note 2.)
Durability (See note 3.)
Mechanical:1,000,000 operations min.
Electrical:500,000 operations min. (10-A resistive load at 250 VAC) Operating speed 0.05 to 0.5 m/s Operating frequency 30 operations/min max. Rated frequency 50/60 Hz
Direct opening force:19.61 N min. (EN60947-5-1) Operating characteristics
Direct opening travel:20 mm min. (EN60947-5-1)
All stroke:23 mm min. Holding force 700 N min. (GS-ET-19) Insulation resistance 100 MΩ min. (at 500 VDC) Rated insulation voltage (Ui) 300 V (EN60947-5-1) Conventional enclosed thermal current
(I
)
the
10 A (EN60947-5-1)
Impulse dielectric strength (U
Dielectric strength (U
imp
)
tween each terminal and ground, and between each terminal and non-current-carrying metal
part;
2.5 kV between solenoid and ground (EN60947-5-1) Conditional short-circuit current 100 V (EN60947-5-1) Pollution degree
(operating environment)
3 (EN60947-5-1)
Protection against electric shock Class I (with ground terminal) Switching overvoltage 1,500 V max. (EN60947-5-1) Contact resistance 50 mΩ max. (initial value) Vibration resistance Malfunction: 10 to 55 Hz, 0.35-mm single amplitude
Shock resistance
Destruction:1,000 m/s
Malfunction:300 m/s Ambient temperature Operating:–10°C to 55°C (with no icing) Ambient humidity Operating:95% max. Weight Approx. 800 g
Current Volt-amperes
) 4 kV (EN60947-5-1) between terminals of different polarity, be-
imp
2
min. (IEC68-2-27)
2
min. (IEC68-2-27)
7,200 VA 720 VA
D4BL
Note: 1. The above values are initial values.
2. Although the switch box is protected from dust, oil or water penetration, do not use the D4BL in places where dust, oil, water, or chemicals
may penetrate through the key hole on the head, otherwise Switch damage or malfunctioning may occur.
3. The durability is for an ambient temperature of 5°C to 35°C and an ambient humidity of 40% to 70%.
G-187F3SL
Solenoid Coil Characteristics
Item 24-VDC mechanical lock models 110-VAC mechanical lock models 24-VAC solenoid lock models
Rated operating voltage 24 VDC
+10%
/
(100% ED) 110 VAC ±10% (50/60 Hz) 24 VDC
–15%
+10%
/
–15%
Current consumption Approx. 300 mA Approx. 98 mA Approx. 300 mA Insulation Class F (130°C or less)
Indicator Characteristics
Item LED
Rated voltage 10 to 115 VAC/VDC Current leakage Approx. 1 mA Color (LED) Orange, green
Contact Form (Diagrams Show State with Key Inserted and Lock Engaged)
Model Contact Diagram Remarks
Lock position
Stroke
Lock position
Stroke
Extraction completion position
Extraction completion position
ON
ON
Only NC contacts 11-12 and 31-32 have an approved direct opening mechanism.
The terminals 11-12 and 23-24 can be used as unlike poles.
NC contacts 11-12, 21-22, and 31-32 have an approved direct opening mechanism.
The terminals 11-12 and 21-22 can be used as unlike poles.
D4BL-#C##-#
1NC/ 1NO+1NC
D4BL-#D##-# 2NC+1NC
31
32 11
23
113231
21
12 24
o
Operation Key insertion comple­tion position
12
22
Operation Key insertion comple­tion position
(100% ED)
Note: The EN-approved direct opening mechanism is indicated by on the switch.
G-188 Safety Sensors / Components
Loading...