Protective Doors Are
Locked Until Machines
Completely Stop Operating
• A mechanical lock is applied automatically when the
Operation Key is inserted. A high level of safety is
achieved using a mechanism where the lock is only
released when voltage is applied to the solenoid.
• Conforms to EN (TÜV) standards corresponding to
the CE marking.
• Approved by UL, CSA, BIA, and SUVA standards.
• The switch contact is opened by a direct opening
mechanism (NC contacts only) when the protective
cover is opened. Direct opening mechanism that is
EN-approved is indicated by on the switch.
• Auxiliary release key ensures easy maintenance
and unlocks the door in the case of a power failure.
• Tough aluminum die-cast body incorporating a
switch box with degree of protection satisfying IP67,
UL, and CSA TYPE6P, 13.
• Equipped with a horizontal and vertical conduit
opening.
• Models incorporating easy-to-see indicators for
monitoring and those using an adjustable Operation
Key for a double door are available.
• The mounting direction of the head can be changed
to allow the Operation Key to be inserted from four
directions.
Conforms to the following EC Directives:
Machinery Directive
Low Voltage Directive
EN1088
G-186Safety Sensors / Components
Approved Standard Ratings
TÜV (EN60947-5-1)
ItemStandard modelIndicator model
Utilization categoryAC-15AC-15
Rated operating current (Ie)3 A6 A
Rated operating voltage (Ue)250 V115 V
Use a 10-A fuse type gI or gG that conforms to IEC269 as a short-circuit protection device.
UL/CSA (UL508, CSA C22.2 No. 14)
A300
Rated voltageCarry current
120 VAC
240 VAC
Note: The UL/CSA approved rating for products with indicators (-A) is 6 A/115 VAC.
10 A
MakeBreakMakeBreak
60 A6 A
30 A3 A
Characteristics
Degree of protectionIP67 (See note 2.)
Durability (See note 3.)
Mechanical:1,000,000 operations min.
Electrical:500,000 operations min. (10-A resistive load at 250 VAC)
Operating speed0.05 to 0.5 m/s
Operating frequency30 operations/min max.
Rated frequency50/60 Hz
Direct opening force:19.61 N min. (EN60947-5-1)
Operating characteristics
Direct opening travel:20 mm min. (EN60947-5-1)
All stroke:23 mm min.
Holding force700 N min. (GS-ET-19)
Insulation resistance100 MΩ min. (at 500 VDC)
Rated insulation voltage (Ui)300 V (EN60947-5-1)
Conventional enclosed thermal current
(I
)
the
10 A (EN60947-5-1)
Impulse dielectric strength (U
Dielectric strength (U
imp
)
tween each terminal and ground, and between each terminal and non-current-carrying metal
part;
2.5 kV between solenoid and ground (EN60947-5-1)
Conditional short-circuit current100 V (EN60947-5-1)
Pollution degree
(operating environment)
3 (EN60947-5-1)
Protection against electric shockClass I (with ground terminal)
Switching overvoltage1,500 V max. (EN60947-5-1)
Contact resistance50 mΩ max. (initial value)
Vibration resistanceMalfunction: 10 to 55 Hz, 0.35-mm single amplitude
Shock resistance
Destruction:1,000 m/s
Malfunction:300 m/s
Ambient temperatureOperating:–10°C to 55°C (with no icing)
Ambient humidityOperating:95% max.
WeightApprox. 800 g
CurrentVolt-amperes
) 4 kV (EN60947-5-1) between terminals of different polarity, be-
imp
2
min. (IEC68-2-27)
2
min. (IEC68-2-27)
7,200 VA720 VA
D4BL
Note: 1. The above values are initial values.
2. Although the switch box is protected from dust, oil or water penetration, do not use the D4BL in places where dust, oil, water, or chemicals
may penetrate through the key hole on the head, otherwise Switch damage or malfunctioning may occur.
3. The durability is for an ambient temperature of 5°C to 35°C and an ambient humidity of 40% to 70%.