CX-Thermo Support Software Ver. 4.0 EST2-2C-MV4
CX-Thermo Support Software Ver. 4.0
EST2-2C-MV4
Monitoring/Setting Support Software for E5CN/CN-H, E5AN/AN-H,
E5EN/EN-H, E5ZN, E5@R/@R-T, and EJ1 Temperature Controllers
Enabling Faster Parameter Setup, Device Adjustment, and
Maintenance
• Enables editing and batch-downloading parameters from a
personal computer, reducing the work required to set parameters.
Usability is improved with table-formatted parameter editing from
version. 4.0.
• Supports Trend Monitoring:
Monitor data (PV,SP,MV,PID parameter, Alarm ON/OFF, etc.) for
up to 31 E5@N/@N-H Temperature Controllers.
Connect up to 64 EJ1N, 17 EJ1G, or 16 E5ZN Temperature
Controllers. (The Temperature Controllers must be from the same
series.)
• Supports parameter masks to hide parameters unnecessary to
display. (Supported only by the E5@N/@N-H and E5@R/@R-T).
• Logic operations enable setting inputs from external inputs (event
inputs) or temperature status, outputs to external outputs (control or
auxiliary outputs), and changing operating status with ON/OFF
delays.
(Supported only by the E5@N/@N-H).
• Easy adjustment of control performance by fine-tuning.
✽ Fine-tuning instructs the CX-Thermo to calculate a PID parameters by
directly inputting commands to improve response.
Ordering Information
List of Models
Specifications
Note: "E5@N" indicates the upgraded versions of the E5CN, E5AN, and E5EN.
Name Model
CX-Thermo Support Software EST2-2C-MV4
Compatible
devices
Temperature
Controllers
E5CN (from April 2004)
E5AN, E5EN (from Feb 2005),
E5CN-H, E5AN-H, E5EN-H
E5AR, E5ER, E5AR-T, E5ER-T
E5ZN
EJ1N-TC4, EJ1N-TC2, EJ1N-HFU (CeliuXº)
EJ1G-TC4, EJ1G-TC2, EJ1G-HFU (CelciuXº Gradient Temperature Control)
G3ZA (only when connected to EJ1N-TC4, EJ1N-TC2, EJ1G-TC4, EJ1G-TC2)
Note: Models with DeviceNet communications are not supported.
Personal
computer
system
requirements
OS Windows 2000 (service pack 3 or higher), XP, or Vista (Japanese or English version)
CPU 300 MHz min.
Memory 128 MB min.
Harddisk 300 MB min. available space
CD-ROM One CD-ROM drive min.
Monitor SVGA (800 × 600) min.
Communications
ports
• RS-232C port, or USB port, 1 port min.
Connection method
• An E58-CIFQ1 USB-Serial Conversion Cable is required to connect a computer to the setup tool port the
E5@N, E5@N-H, or EJ1.
• A K3SC Interface Converter is used to connect a computer to models with RS-422/RS-485.
• An E58-CIFIR USB-Infrared Conversion Cable is required to wirelessly connect a computer to models with
infrared communications (E5AN-H or E5EN-H).