with ComFit
TM
Cuff
Model BP791IT
INSTRUCTION MANUAL
ENGLISH
Page 2
2
Before Using the Monitor
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Operating the Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Risk of Electrical Shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Before Taking a Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Operating Instructions
Know Your Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Unit Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Display Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Irregular Heartbeat Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Movement Error Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
USER ID Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Morning Hypertension Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Heartbeat Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Average Value Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Morning Average Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Evening Average Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Cuff Wrap Guide Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Using the AC Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Battery Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Setting the Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Setting TruRead
TM
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Applying the Arm Cuff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
TABLE OF CONTENTS
Page 3
Taking a Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Calibration Check System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Cuff Wrap Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Using the Guest Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Selecting the USER ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Using the USER ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Using the Single Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Using the TruRead
TM
Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Special Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
Using the Memory Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Averaging Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
To Display the Measurement Values . . . . . . . . . . . . . . . . . . . . . . . .39
Morning and Evening Averages . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
To Display Morning and Evening Averages . . . . . . . . . . . . . . . . . .42
Display Combinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
To Delete All Values Stored in the Memory . . . . . . . . . . . . . . . . . .44
Downloading Instructions
Installing the Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
Downloading and Installing Microsoft®HealthVault
TM
. . . . . . . . .45
Downloading and Installing Omron Health
Management Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Using the Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
Care and Maintenance
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
Error Indicators and Troubleshooting Tips . . . . . . . . . . . . . . . . . . . . . . . . .55
FCC Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
TABLE OF CONTENTS
3
Page 4
4
Thank you for purchasing the Omron®BP791IT 10 series Plus Automatic Blood Pressure Monitor with ComFit
TM
Cuff.
INTRODUCTION
Fill in for future reference.
DATE PURCHASED: __________________ SERIAL NUMBER: ____________________
Your new blood pressure monitor uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood’s movement through your brachial artery and converts the movements into a digital reading. The monitor stores measurement results for two people and features Morning and Evening Averages. TruRead
TM
allows for three consecutive measurements with timed
intervals for an average reading. The BP791IT comes with the following components:
• Monitor • ComFit
TM
Cuff • AC Adapter
• 4 “AA” Alkaline Batteries • Storage Case • USB Cable
• Instruction Manual printed in English and Spanish
• Quick Start Guide The BP791IT 10 series Plus Automatic Blood Pressure Monitor is
intended for home use.
Please read this instruction manual thoroughly before using the unit. Please keep for future reference. For specific information about your own blood pressure, CONSULT YOUR DOCTOR.
SAVE THESE INSTRUCTIONS
Before Using the Monitor
• Staple your purchase receipt here
• Register your product on-line at www.register-omron.com
Page 5
5
To assure the correct use of the product basic safety measures should always be followed including the warnings and cautions listed in this instruction manual.
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property.
OPERATING THE DEVICE
Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider.
DO NOT adjust medication based on measurement results from this blood pressure monitor. Take medication as prescribed by your physician. Only a physician is qualified to diagnose and treat High Blood Pressure.
The monitor is not intended to be a diagnostic device. If battery fluid should get in your eyes, immediately rinse with
plenty of clean water. Contact a physician immediately.
Read all of the information in the instruction manual and any other literature in the box before operating the unit.
SAFETY INFORMATION
Page 6
OPERATING THE DEVICE (continued)
This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions.
Read the Special Conditions section (page 37) of the instruction manual if your systolic pressure is known to be more than 220 mmHg. Inflating to a higher pressure than necessary may result in bruising where the cuff is applied.
Operate the device only as intended. Do not use the device for any other purpose.
Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.
Do not use a cellular phone near the device. It may result in an operational failure.
Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit.
Use only 1.5V alkaline batteries with this device. Do not use other types of batteries. This may damage the unit.
SAFETY INFORMATION
6
Page 7
RISK OF ELECTRICAL SHOCK
Do not plug or unplug the power cord into the electrical outlet with wet hands.
Do not overload power outlets. Plug the device into the appropriate voltage outlet.
CARE AND MAINTENANCE
Do not subject the monitor to strong shocks, such as dropping the unit on the floor.
Do not submerge the device or any of the components in water.
Store the device and the components in a clean, safe location.
Changes or modification not approved by Omron Healthcare will void the user warranty. Do not disassemble or attempt to repair the unit or components.
SAFETY INFORMATION
7
Page 8
8
BEFORE TAKING A MEASUREMENT
To ensure a reliable reading follow these recommendations:
1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes prior to taking a measurement. Rest for at least 15 minutes prior to taking the measurement.
2. Stress raises blood pressure. Avoid taking measurements during stressful times.
3. Measurements should be taken in a quiet place.
4. Remove tight-fitting clothing from your arm.
5. Sit on a chair with your feet flat on the floor. Rest your arm on a table so that the cuff is at the same level as your heart.
6. Remain still and do not talk during the measurement.
7. Keep a record of your blood pressure and pulse readings for your physician. A single measurement may not provide an accurate indication of your true blood pressure. You need to take and record several readings over a period of time. Try to measure your blood pressure at about the same time each day for consistency.
Page 9
9
KNOW YOUR UNIT
Main Unit:
Air Jack
Battery Compartment
Start/Stop Button
USER ID Selection Switch
Morning/Evening Average ( ) Button
Memory ( ) Button
Display
AC Adapter Jack
Operating Instructions
Up/Down (
/
) Buttons
Calibration Check System
SET Button
USB Port
Page 10
KNOW YOUR UNIT
10
Components:
Arm Cuff
Air Tube
Air Plug (Connects to Air Jack)
AC Adapter
Storage Case
Housing
Cord
10 series
Plus
Blood Pressure Monitor
with ComFitTMCuff
Model BP791IT
INSTRUCTION MANUAL
ESPAÑOL
ENGLISH
Quick Start Guide
Instruction Manual
USB Cable
4 AAAlkaline Batteries
Page 11
11
UNIT DISPLAY
Diastolic Blood Pressure
Systolic Blood Pressure
Movement Symbol
Pulse Display / Memory Number
Date/Time Display
Low Battery Indicator
Deflation Symbol
Morning Average Symbol
Heartbeat Symbol
Irregular Heartbeat Symbol
Evening Average Symbol
Average Value Symbol
Memory Symbol
USER ID Symbol (A or B)
Morning Hypertension Symbol
Week Display
TruRead
TM
Symbol
Blood Pressure Level Indicator
Cuff Wrap Guide
Page 12
12
IRREGULAR HEARTBEAT SYMBOL ( )
When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the measurement values.
An irregular heartbeat rhythm is defined as a rhythm that varies by less than 25% from the average rhythm or 25% more than the average rhythm detected while the monitor is measuring the systolic and diastolic blood pressure.
If the irregular heartbeat symbol ( ) displays with your measurement results, we recommend you consult your physician. Follow the directions of your doctor.
MOVEMENT ERROR SYMBOL ( )
The Movement Error Symbol is displayed if you move your body during the measurement. Please remove the arm cuff, and wait 2-3 minutes. Take another measurement, remain still during inflation.
USER ID SYMBOL (
/
)
The USER ID Symbol indicates USER A or USER B as selected by the user to take a measurement or when using the memory function. The USER ID Symbol is not displayed when using the Guest Mode to take a measurement.
Normal Heartbeat
Irregular Heartbeat
Pulse
Blood
pressure
Pulse
Blood
pressure
Short Long
DISPLAY SYMBOLS
Page 13
Internationally recognized guidelines for upper limit of normal home blood pressure readings are as follows:
Home Guideline for Upper Limit of Normal BP
Systolic Blood Pressure 135 mmHg Diastolic Blood Pressure 85 mmHg This is a general guideline because blood pressure depends on
age and morbidity. A lower home blood pressure goal may be recommended for certain patients, including diabetic patients, pregnant women, and patients with renal failure.
The monitor is not intended to be a diagnostic device.
MORNING HYPERTENSION SYMBOL ( )
The Morning Hypertension Symbol is displayed if the morning average reading for a week is above 135 for the Systolic Blood Pressure value and/or 85 for the Diastolic Blood Pressure value when viewing the Morning Averages and the Evening Averages in the memory.
Omron Healthcare recommends you contact your physician if the MORNING HYPERTENSION SYMBOL appears on the display with your measurement values.
DISPLAY SYMBOLS
13
Page 14
HEARTBEAT SYMBOL ( )
The Heartbeat symbol flashes on the display at every heartbeat during the measurement.
AVERAGE VALUE SYMBOL ( )
The Average Value Symbol is displayed when you press the memory button. The most recent average reading appears on the display screen.
MORNING AVERAGE SYMBOL ( )
The Morning Average symbol is displayed when viewing Morning Averages using the Memory Function.
EVENING AVERAGE SYMBOL ( )
The Evening Average symbol is displayed when viewing Evening Averages using the Memory Function.
CUFF WRAP GUIDE SYMBOL ( / )
When the cuff is wrapped around the arm correctly, ( ) is displayed while taking a measurement or using the memory function. If the cuff is
not wrapped around the arm correctly, ( ) is displayed.
DISPLAY SYMBOLS
14
Page 15
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
NOTES: • Use only the authorized Omron AC Adapter that came with
this monitor.
• We recommend you install the batteries even if the AC Adapter is used. If no batteries are installed, you may need to reset the date and time if the AC Adapter is disconnected. The measurement results will not be deleted.
CAUTION
Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit.
USING THE AC ADAPTER
15
- DANGER -
TO REDUCE THE RISK OF
FIRE OR ELECTRIC SHOCK,
CAREFULLY FOLLOW THESE INSTRUCTIONS.
For connection to a power supply not in the U.S.A., use an attachment plug adapter of the proper configuration for the power outlet.
The power unit (AC Adapter) is intended to be correctly oriented in a vertical or floor mount position.
Page 16
TO CONNECT THE AC ADAPTER
Insert the AC Adapter Plug into
the AC Adapter Jack on the back side of the monitor as illustrated.
Plug the AC Adapter into a 120V
AC outlet (60 cycles).
TO DISCONNECT THE AC ADAPTER
Hold the Housing to remove the AC Adapter from the electrical
outlet.
Remove the AC Adapter plug from the monitor.
WARNING
Do not plug or unplug the power cord into the electrical outlet with wet hands.
WARNING
Do not overload power outlets. Plug the device into the appropriate voltage outlet.
USING THE AC ADAPTER
16
Housing
Cord
Page 17
1. Remove the battery cover by pulling the hook up while pushing it in the direction of the arrow.
2. Install 4 “AA” size batteries so the + (positive) and - (negative) polarities match the polarities of the battery compartment as indicated.
3. Replace the battery cover.
BATTERY INSTALLATION
17
Battery Cover
Page 18
BATTERY REPLACEMENT
When the Low Battery Indicator appears on the display screen turn the monitor off and remove all the batteries. Replace with four new batteries at the same time. Longlife alkaline batteries are recommended.
WARNING
If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Contact a physician immediately.
NOTES: • Turn the unit off before replacing the batteries. If the
batteries are removed while the unit is still on, the date and time will be reset to that of the previous use. However, the measurement results are not deleted.
• When the batteries are replaced, you may need to reset the date and time. If "-:--" appears on the display, refer to “Setting the Date and Time”.
• The supplied batteries may have a shorter life.
CAUTION
Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.
BATTERY INSTALLATION
18
Low Battery Indicator
Page 19
19
Set the monitor to the current date and time before taking a measurement for the first time. If the date and time are not set correctly, the measurement values stored in the memory and the average values may not be correct.
If the date and time are not set, “-:--” appears during or after measurement.
The Blood Pressure Monitor automatically stores up to 100 measurement values per user with the dates and times. The monitor also calculates weekly averages for measurements in the morning and in the evening. Morning and Evening averages are stored for this week and the last seven weeks.
The monitor can also calculate an average reading based on the three most recent measurements taken within 10 minutes of the last reading.
NOTE: • If only two readings are stored in the memory for the 10-
minute period, the average is based on the two readings.
• If one reading is stored in the memory for the 10-minute period, this reading is displayed as the average.
SETTING THE DATE AND TIME
Page 20
20
SETTING THE DATE AND TIME
1. TO START THE SETTING
Press and hold the SET button to adjust the date and time.
The year flashes on the display.
2. SETTING THE YEAR
The year can be set between 2010 and
2040. When the display reaches 2040, it will return to 2010.
Press the Up button ( ) to advance by one year.
Press the SET button to set the current year.
The month flashes on the display.
NOTES: • Press the Down button ( ) to decrease the date and time
values.
• Press and hold the Up or Down button to increase or decrease the date and time values faster.
Page 21
3. SETTING THE MONTH
Press the Up button ( ) to advance by one month.
Press the SET button to set the current month.
The day flashes on the display.
4. SETTING THE DAY
Press the Up button ( ) to advance by one day.
Press the SET button to set the current day.
The hour flashes on the display.
21
SETTING THE DATE AND TIME
Page 22
22
5. SETTING THE HOUR
The time is set using AM or PM. Press the Up button ( ) to advance
by one hour. Press the SET button to set the current
hour.
The minute flashes on the display.
6. SETTING THE MINUTE
Press the Up button ( ) to advance by one minute. Press the SET button to set the minute setting.
7. TO TURN THE MONITOR OFF
Press the START/STOP button.
SETTING THE DATE AND TIME
Page 23
The TruRead
TM
Mode takes three consecutive measurements.
The monitor will inflate, take a measurement, and deflate three times separated by a short interval of time between each measurement.
1. Select your USER ID (A or B).
2. Press the SET button. The TruRead
TM
symbol and the oFF setting appears
on the display.
3. Press the Up or Down button (
/ ) to select on.
NOTE: Press the Up or Down button
to alternate between on and oFF.
SETTING TRUREAD
TM
23
Page 24
4. Press the SET button to confirm the change.
If on is selected, the number of seconds between each measurement is displayed. NOTE: The default value between each measurement is 60 seconds.
5. Press the Up or Down button ( / ) to change the interval of
time between each measurement.
The interval can be set to 15 seconds, 30 seconds, 60 seconds or 120 seconds. Continue to press the Up or Down button until the desired interval appears on the display.
6. Press the SET button to confirm the setting. The year flashes on the display.
SETTING TRUREAD
TM
24
Page 25
7. If the date and time are correct, press the START/STOP button to turn
the monitor off. To change the date and time, refer to “Setting the Date and Time”.
SETTING TRUREAD
TM
25
Page 26
CAUTION
Read all of the information in the instruction manual and any other literature in the box before operating the unit.
CAUTION
This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions.
APPLYING THE CUFF ON THE LEFT ARM
1. Make sure the air plug is securely inserted in the main unit.
2. Remove tight-fitting clothing from your upper left arm.
APPLYING THE ARM CUFF
26
Page 27
27
3. Sit on a chair with your feet flat on the floor. Place your left arm
on a table so the cuff is level with your heart.
4. Hold the thumb grip on the cuff
securely with your right hand.
5. Turn the palm of your left hand upward.
APPLYING THE ARM CUFF
Thumb Grip
Cloth Fastener
Page 28
28
6. Apply the cuff to your left upper arm so the blue stripe is on the
inside of your arm and aligned with your middle finger. The air tube runs down the inside of your arm. The bottom of the cuff should be approximately 1/2" above your elbow.
7. Wrap the cuff firmly in place around your arm using the cloth
fastener.
APPLYING THE ARM CUFF
1/2 inch (1 - 2 cm)
Air Tube
Blue Stripe
Page 29
APPLYING THE CUFF ON THE RIGHT ARM
When taking a measurement using the right arm use this instruction for Step 6 on page 28.
Apply the cuff to your right upper arm so the thumb grip is centered on the inside of your inner arm. The bottom of the cuff should be approximately 1/2'' above your elbow.
NOTE: Be careful not to rest your arm on the air tube. This will restrict
the flow of air to the cuff.
APPLYING THE ARM CUFF
29
Thumb Grip
Page 30
The monitor is designed to take measurements and store the measurement values in the memory for two people using USER ID A and USER ID B.
The monitor can also be used to take a single measurement for other persons using the GUEST Mode. The USER ID symbol is not displayed when using the GUEST Mode. Measurements taken using the GUEST Mode are not stored in the memory.
WARNING
Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider.
CAUTION
Operate the device only as intended. Do not use the device for any other purpose.
CALIBRATION CHECK SYSTEM
When you press the START/STOP button, the Calibration Check System light turns on and the unit starts monitoring your readings using dual sensors. If the unit is accurate and functioning correctly, the Calibration Check System light remains lit during the measurement. If an error is detected, the Calibration Check System light flashes and “ER” will appear on the display.
CUFF WRAP GUIDE
This monitor checks whether the arm cuff is wrapped around the arm correctly during the inflation. When the cuff is wrapped correctly, is displayed while taking a measurement or using the memory function. If the cuff is not wrapped correctly, is displayed. If is displayed, refer to the section “Applying the Arm Cuff”, wrap the cuff firmly around the arm and take another measurement.
TAKING A MEASUREMENT
30
Page 31
USING THE GUEST MODE
1. Press and hold the START/STOP button.
The A and B Symbols disappear from the display.
2. Release the START/STOP button.
The cuff starts to inflate automatically.
NOTE: To stop the inflation press the START/STOP button.
The monitor will stop inflating, start deflation and turn off.
3. Inflation stops and the measurement is started. When the
measurement is completed, your blood pressure and pulse rate appear on the display.
TAKING A MEASUREMENT
31
A and B Symbols disappear
Page 32
SELECTING THE USER ID
Select your USER ID. Always use the same USER ID when taking a measurement. The monitor stores the measurement values in the memory by the USER ID selected. These measurement values are used to calculate the Morning Averages and Evening Averages.
Slide the USER ID Selection Switch right or left to select USER A or B.
USING THE USER ID
After you select a USER ID, the monitor can be set to take one measurement using the Single Mode or three consecutive measurements using the TruReadTMMode.
NOTE: The default value is set to the Single Mode to take one
measurement. Refer to “Setting TruRead
TM
”.
TAKING A MEASUREMENT
32
Page 33
USING THE SINGLE MODE
1. Select your USER ID (A or B).
2. Press the START/STOP button.
All symbols appear on the display. The USER ID Symbol you selected flashes on the display.
The cuff starts to inflate automatically. As the cuff inflates, the monitor automatically determines your ideal inflation level. This monitor detects the pulse during inflation. Do not move your arm and remain still until the entire measurement process is completed.
NOTE: To stop the inflation or measurement, press the START/STOP
button. The monitor will stop inflating, start deflating and will turn off.
TAKING A MEASUREMENT
33
Page 34
3. Inflation stops automatically and the measurement is started.
As the cuff deflates, decreasing numbers appear on the display. The Heartbeat Symbol ( ) flashes at every heartbeat.
4. When the measurement is complete, the arm cuff
completely deflates. Your blood pressure and pulse rate are displayed.
5. Press the START/STOP button to turn the
monitor off. NOTE: The monitor will automatically turn
off after two minutes.
TAKING A MEASUREMENT
34
Page 35
USING THE TRUREAD
TM
MODE
1. Select your USER ID (A or B).
2. Press the START/STOP button.
All symbols appear on the display. The USER ID Symbol you selected flashes on the display. The cuff starts to inflate automatically.
NOTE: To stop the inflation or measurement, press the START/STOP
button. The monitor will stop inflating, start deflating and will turn off.
3. Inflation stops automatically and the measurement is started.
As the cuff deflates, decreasing numbers appear on the display. The Heartbeat Symbol ( ) flashes at every heartbeat. When the
measurement is complete, the arm cuff completely deflates. NOTE: Do not move your arm and remain still until the entire
measurement process is completed.
4. Check the progress of the consecutive measurements.
NOTE: If a measurement fails, the monitor will repeat taking
a measurement up to five times during the consecutive measurement process.
The first measurement is complete, waiting to start the next measurement. The interval of time set between each measurement will appear on the display.
TAKING A MEASUREMENT
35
Page 36
TAKING A MEASUREMENT
36
The second measurement is complete, waiting to start the next measurement.
The consecutive measurements are complete. The average for three measurements appears on the display.
5. Press the SET button to display the blood pressure and pulse rate for
the first measurement. Press the SET button again to display the next measurement.
6. Press the START/STOP button to turn the monitor off.
WARNING
Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider.
WARNING
DO NOT adjust medication based on measurement results from this blood pressure monitor. Take medication as prescribed by your physician. Only a physician is qualified to diagnose and treat High Blood Pressure.
Page 37
TAKING A MEASUREMENT
37
If your systolic pressure is known to be more than 220 mmHg, press and hold the START/STOP button until the monitor inflates 30 to 40 mmHg higher than your expected systolic pressure.
NOTES: • Do not apply more pressure than necessary.
• The monitor will not inflate above 299 mmHg. When the measurement is complete, the arm cuff completely deflates. Your blood pressure and pulse rate are displayed.
WARNING
The monitor is not intended to be a diagnostic device.
SPECIAL CONDITIONS
CAUTION
Inflating to a higher pressure than necessary may result in bruising where the cuff is applied.
Page 38
The monitor is designed to store the blood pressure and the pulse rate in the memory for two people (USER A and USER B) every time a measurement is completed.
The monitor automatically stores up to 100 sets of measurement values (blood pressure and pulse rate) for each user (A and B). When 100 sets of measurement values are stored, the oldest record is deleted to save the most recent values. The monitor also stores 8 weeks of Morning Averages and 8 weeks of Evening Averages for each user (A and B).
AVERAGING FUNCTION
The monitor calculates the average reading based on the three most recent sets of measurement values taken within 10 minutes of the most recent reading.
NOTES: • If two sets of measurement values are stored in the memory
for the 10 minutes period, the average is based on the two sets of measurement values. If one set of measurement values is stored, this is displayed as the average.
• When viewing the reading taken without setting the date and time, “-:--” is displayed instead of the date and time.
USING THE MEMORY FUNCTION
38
Page 39
TO DISPLAY THE MEASUREMENT VALUES
1. Select your USER ID (A or B).
2. Press the Memory button ( ).
The Average Symbol ( ) appears on the display when the average reading is shown.
USING THE MEMORY FUNCTION
39
Page 40
3. Press the Down button ( ) to display the most recent set of measurement values on the screen. The values are displayed from the most recent to the oldest.
NOTE: The date and time are alternately
displayed with the measurement values.
Press the Up or Down button to display the next set of values.
: To the older readings : To the more recent readings
NOTE: Press and hold the Up or Down button to display the values
faster.
TruRead
TM
Mode
The average for the consecutive measurements appears on the display with the TruRead
TM
symbol ( ). To display the values for the individual measurements press the SET button while the average is displayed.
4. Press the START/STOP button to turn the power off.
USING THE MEMORY FUNCTION
40
Alternating display
Page 41
MORNING AND EVENING AVERAGES
The monitor calculates and displays a weekly average for measurements taken in the morning ( ) and evening ( ). The monitor stores 8
weeks of Morning Averages and 8 weeks of Evening Averages for each user (A and B).
NOTE: The week begins Sunday at 4:00 AM.
MORNING AVERAGES
Morning averages are based on the first average reading using the TruReadTMMode or the first reading using the Single Mode.
Measurement times must be between:
4:00 AM and 9:59 AM.
EVENING AVERAGES
Evening averages are based on the last average reading using the TruReadTMMode or the last reading using the Single Mode.
Measurement times must be between:
7:00 PM and 1:59 AM.
USING THE MEMORY FUNCTION
41
Page 42
TO DISPLAY MORNING AND EVENING AVERAGES
1. Select your USER ID (A or B).
2. Press the Morning/ Evening Average button ( ) to select
the Morning or Evening average. The average for the current week
“THIS WEEK” appears on the display.
3. Press the Down ( ) button to display the previous weeks.
With each press of the Down ( ) button, the values are displayed from 1 week ago to the older. With each press of the Up ( ) button, the values are displayed from 7 weeks ago to the recent.
NOTE: If no measurement is taken in a given week, the
display will appear as illustrated.
4. Press the START/STOP button to turn the monitor off.
USING THE MEMORY FUNCTION
42
Page 43
43
USING THE MEMORY FUNCTION
DISPLAY COMBINATIONS
In addition to the Morning Average and Evening Average Symbols, the monitor may also display the Morning Hypertension Symbol if the morning average for that week is above the internationally recognized guidelines. (See page 13 for details.) Depending on your measurement results, these may be displayed in the following combinations.
Display
Average above internationally
recognized guidelines + Morning
Hypertension
Average within internationally
recognized guidelines
Morning
Average
Evening Average
Morning average from This Week with Morning Average Symbol
Morning average from 7 weeks ago with Morning Average Symbol + Morning Hypertension Symbol
Evening average from This Week with Evening Average Symbol
Evening average from 7 weeks ago with Evening Average Symbol + Morning Hypertension Symbol
Page 44
44
The Morning Hypertension Symbol ()appears if the weekly average for morning measurements is above 135/85.
In this case the Morning Hypertension Symbol
()is displayed when
the Evening Average is displayed, regardless of the values for the Evening Average.
TO DELETE ALL VALUES STORED IN THE MEMORY
The values stored in the memory are deleted by USER ID. You cannot partially delete values stored in the memory. All values for
the user you select will be deleted.
1. Select your USER ID (A or B).
2. While holding the Memory button ( ) and the START/STOP button simultaneously for more than 2 seconds all values will be deleted.
USING THE MEMORY FUNCTION
Page 45
Optional Instructions for PC Connection
To install software, choose either Microsoft®HealthVaultTMor Omron Health Management software.
NOTE: Any measurement values taken before setting the date and time
are not transferred to Microsoft HealthVault
TM
and Omron Health
Management software.
DOWNLOADING AND INSTALLING MICROSOFT
®
HEALTHVAULT
TM
HealthVault is a free Web-based platform designed to put people in control of their health data. It helps them collect, store and share health information with family members and participating healthcare providers, and provides people with a choice of third-party applications and devices to help them manage things such as fitness, diet and health.
1. Go to http://www
.healthvault.com/hvcc/system-requirements.aspx
2. Create a HealthVault account to store your blood pressure data online.
3. Track your progress and manage your health goals using HealthVault.
INSTALLING THE SOFTWARE
45
Downloading Instructions
Page 46
OPERATING ENVIRONMENT REQUIREMENTS
The following operating environments are required to run Microsoft
®
HealthVault.
Supported OS*: HealthVault works best with the following operating systems:
Either 32-bit or 64-bit versions of:
Microsoft®Windows®7®Home Premium Windows®7®Professional Windows®7®Ultimate
Either 32-bit or 64-bit versions of:
Microsoft®Windows®Vista®Home Basic Windows®Vista®Home Premium Windows®Vista®Business Windows®Vista®Enterprise Windows®Vista®Ultimate
32-bit versions of:
Windows®XP Home Edition Service Pack 2 (SP2) Windows®XP Professional SP2 Windows®XP Tablet PC Edition SP2 Windows®XP Media Center Edition 2005 (Rollup Update 2) Windows®XP Service Pack 3 (SP3)
HealthVault won’t run on versions of Windows®earlier than Windows
®
XP SP2, any 64-bit version of Windows®XP, Windows®Vista®Starter edition, or any version of Windows®Server.
Memory capacity: 512 MB (minimum)/1 GB (recommended) Processor: 1 GHz Hard disc space: 200 MB Internet connection: Broadband Display resolution: 1024 × 768
* To view details about your computer:
1. Go to the Start menu.
2. Select Control Panel.
3. Select System and Maintenance.
4. Select System.
5. From this screen you can see your operating system, RAM, processor, system type, and other details about your computer.
INSTALLING THE SOFTWARE
46
Page 47
DOWNLOADING AND INSTALLING OMRON HEALTH MANAGEMENT SOFTWARE
Omron Health Management Software allows you to view, process and print data about blood pressure and walking measured by Omron’s compatible blood pressure monitor and pedometer.
• To install Omron Health Management Software onto your PC, you
must have administrative privileges.
• Close all applications currently running before you install the software.
• When using anti-virus software, disable anti-virus software before
installation. It may interfere with the set-up program of this software. Enable the anti-virus software again after installation is complete.
1. Download the Omron Health Management Software at www
.software.omronhealthcare.com. Follow the installation directions when prompted. Read the License Agreements thoroughly and accept the terms if you agree. Once Omron Health Management Software is installed, continue to the next section, “Using the Software”.
2. After downloading the software, extract a zip file and double-click the [setup.exe] icon.
INSTALLING THE SOFTWARE
47
Page 48
OPERATING ENVIRONMENT REQUIREMENTS
The following operating environments are required to run the Omron Health Management software.
Supported OS: Microsoft®Windows®2000 Professional (SP4)
Microsoft®Windows®XP Home Edition (SP2) Microsoft®Windows®XP Professional (SP2) Microsoft®Windows®Vista®Home Basic Microsoft®Windows®Vista®Home Premium Microsoft®Windows®Vista®Business Microsoft®Windows®Vista®Enterprise Microsoft®Windows®Vista®Ultimate Microsoft®Windows®7®Starter Microsoft®Windows®7®Home Basic Microsoft®Windows®7®Home Premium Microsoft®Windows®7®Professional Microsoft®Windows®7®Enterprise Microsoft®Windows®7®Ultimate
PC: 800 MHz or higher CPU, PC/AT compatible machine Memory capacity: 512 MB or more Hard disc space: 32 MB or more* Display: Super VGA (800 × 600 pixel) or higher resolution video
adapter and monitor
Others: USB connector (USB Revision 1.1 compliant)
Adobe Acrobat Reader 5.0 or higher
NOTE: If the OS environmental requirements are above those listed,
then additional resources may be required.
*Additional 200 MB is necessary in the case that Microsoft.
NET or MDAC is not installed.
Trademark and Registered trademark
• Microsoft
®
and Windows®are registered trademarks in the United
Sates and other countries.
• Adobe
®
, Adobe logo, Acrobat®and Reader®are registered trademarks or trademarks of Adobe Systems Incorporated in the United States and other countries.
INSTALLING THE SOFTWARE
48
Page 49
For help using the software, double-click [Omron Health Management Software Users Manual.pdf] shortcut on
desktop, or click [Help] in this software after starting up.
1. Double-click the [Omron Health Management Software] shortcut icon on the desktop.
If no icon appears on the desktop: From the [Start] menu, select [All programs] or [Programs] [Omron Health Management Software], and click the [Omron Health Management Software] shortcut.
2. If you are using Omron Health Management Software for the first time, click [Add User] on the User Management screen.
USING THE SOFTWARE
49
Page 50
3. In the New User Registration box, enter your name (e.g., Chuck) and click [OK].
NOTES:
• Omron Health Management
Software can manage multiple users’ data. Data is controlled by user name.
• The number of users who can register for this software varies
depending on the amount of free disc space in your PC.
• The user name can be up to 28 characters.
4. Click the user name, and click [Graph Screen].
5. Click the [Blood Pressure Monitor] icon.
USING THE SOFTWARE
50
Page 51
Use only the authorized Omron USB cable, Model HHX-CABLE­USB2, included with this unit.
CAUTION
Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit.
1. Open the USB Port cover.
2. Plug the normal USB Connector
(Large Connector) into the personal computer.
3. Plug the mini USB connector
(Small Connector) into the USB Port.
NOTE: You cannot take a
measurement while connecting the USB cable.
USING THE SOFTWARE
51
Normal USB Connector
Mini USB Connector
Page 52
4. Click [Download Data] icon to import the data.
5. The Confirm dialog
appears. Make sure your cable is connected then click [Yes].
6. Select the blood pressure
monitor being used and click [OK].
7. Start importing data. Click
[Cancel] if you want to cancel.
8. The dialog appears when complete. Click [OK]
and view your data on the graph.
USING THE SOFTWARE
52
Page 53
53
To keep your blood pressure monitor in the best condition and protect the unit from damage, follow the directions listed below:
Keep the monitor in the storage case
when not in use. Make sure the AC adapter is placed under the main unit so that it does not damage the display. Avoid kinking or sharply bending the AC Adapter cord.
Do not forcefully bend the arm cuff or air tube. Do not fold tightly.
Clean the monitor with a soft dry cloth. Do not use any abrasive or volatile cleaners. Do not attempt to clean the cuff.
CAUTION
Do not submerge the device or any of the components in water. Do not subject the monitor to extreme hot or cold temperatures, humidity or direct sunlight.
CAUTION
Store the device and the components in a clean, safe location.
CAUTION
Do not subject the monitor to strong shocks, such as dropping the unit on the floor.
Remove the batteries if the unit will not be used for three months or longer. Always replace all the batteries with new ones at the same time.
CARE AND MAINTENANCE
Care and Maintenance
Page 54
Use the unit consistent with the instruction provided in this manual.
CAUTION
Changes or modification not approved by Omron Healthcare will void the user warranty. Do not disassemble or attempt to repair the unit or components.
CAUTION
Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit.
CARE AND MAINTENANCE
54
Page 55
Contact Customer Service for repair information.Sensor may be out of alignment.
Refer to “Applying the Arm Cuff”.
Cuff is not applied correctly.
Air plug disconnected.
Insert the plug securely. Refer to “Applying the Arm Cuff”.
Arm cuff not applied correctly.
Apply the arm cuff correctly. Refer to “Applying the Arm Cuff”.
Air is leaking from the arm cuff.
Replace the cuff with the new one.
Cuff over or under inflated.
Repeat measurement. Remain still and do not talk during measurement. Refer to “Taking a Measurement”.
If “E2” appears repeatedly, inflate the cuff manually until it is 30 to 40 mmHg above your previous measurement result. Refer to “Taking a Measurement”.
The arm cuff was inflated above 299 mmHg when inflating the cuff manually.
Do not inflate the cuff above 299 mmHg. Refer to “Taking a Measurement”.
Movement during measurement.
Repeat measurement. Remain still and do not talk during measurement. Refer to “Taking a Measurement”.
Clothing is interfering with the arm cuff.
Remove any clothing interfering with the arm cuff. Refer to “Applying the Arm Cuff”.
Device error.
Contact Customer Service.
55
SYMBOL CAUSE CORRECTION
ERROR INDICATORS
ERROR INDICATORS AND TROUBLESHOOTING TIPS
Page 56
56
ERROR INDICATORS AND TROUBLESHOOTING TIPS
PROBLEM CAUSES AND SOLUTIONS
No power.
No display appears on the unit.
Replace all four batteries with new ones. Check the battery installation for proper placement of the battery polarities.
Measurement values appear too high or too low.
Blood pressure varies constantly. Many factors including stress, time of day, and how you wrap the cuff, may affect your blood pressure. Review the sections “Before Taking a Measurement” and “Taking a Measurement”.
TROUBLESHOOTING TIPS
SYMBOL CAUSE CORRECTION
Batteries are worn.
Replace the four batteries. Refer to “Battery Installation”.
ERROR INDICATORS
Page 57
57
FCC STATEMENT
NOTE:
POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for U.S.A. only) This product has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. The product generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If the product does cause harmful interference to radio or television reception, which can be determined by turning the product on and off, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the product and the receiver.
• Connect the product into an outlet on a circuit different from that to which
the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
POTENTIAL FOR RADIO/TELEVISION INTERFERENCE (for Canada only) This digital apparatus does not exceed the Class B limits for radio noise
emissions from digital apparatus as set out in the interference-causing equipment standard entitled “Digital Apparatus”, ICES-003 of the Canadian Department of Communications.
Cet appareil numérique respecte les limites de bruits radioeléctriques applicables aux appareils numériques de Clase B prescrites dans la norme sur le materiel brouilleur: “Appareils Numériques”, ICES-003 édictée par le minister des communications.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Page 58
LIMITED WARRANTY
58
Your Omron®BP791IT 10 series Plus Automatic Blood Pressure Monitor, excluding the arm cuff and batteries, is warranted to be free from defects in materials and workmanship appearing within 5 years from the date of purchase, when used in accordance with the instructions provided with the monitor. The arm cuff is warranted to be free from defects in materials and workmanship appearing within one year from the date of purchase when the monitor is used in accordance with the instructions provided with the monitor. The above warranties extend only to the original retail purchaser.
We will, at our option, repair or replace without charge any monitor or arm cuff covered by the above warranties. Repair or replacement is our only responsibility and your only remedy under the above warranties.
To obtain warranty service contact Customer Service by calling 1-800-634-4350 for the address of the repair location and the return shipping and handling fee.
Enclose the Proof of Purchase. Include a letter, with your name, address, phone number, and description of the specific problem. Pack the product carefully to prevent damage in transit. Because of possible loss in transit, we recommend insuring the product with return receipt requested.
THE FOREGOING IS THE SOLE WARRANTY PROVIDED BY OMRON IN CONNECTION WITH THIS PRODUCT, AND OMRON HEREBY DISCLAIMS ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IMPLIED WARRANTIES AND OTHER TERMS THAT MAY BE IMPOSED BY LAW, IF ANY, ARE LIMITED IN DURATION TO THE PERIOD OF THE ABOVE EXPRESS WARRANTY.
OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER SPECIAL, INCIDENTAL, CONSEQUENTIAL OR INDIRECT COSTS, EXPENSES OR DAMAGES.
This warranty provides you with specific legal rights, and you may have other rights that vary by jurisdiction. Because of special local requirements, some of the above limitations and exclusions may not apply to you.
FOR CUSTOMER SERVICE
Visit our web site at: www.omronhealthcare.com Call toll free: 1-800-634-4350
Page 59
59
Model: BP791IT (HEM-7222-ITZ) Display: LCD Digital Display Measurement Range: Pressure: 0 to 299 mmHg, Pulse: 40 to 180/min. Accuracy/Calibration: Pressure: ±3mmHg or 2% of reading
Pulse: ±5% of reading Inflation: Automatic by electric pump Deflation: Automatic pressure release valve Rapid Air Release: Automatic exhaust valve Measurement Method: Oscillometric method Power Source: 120V 60Hz AC adapter or 4 “AA” batteries Battery Life: Approx. 300 uses when used 6 times a day
with 4 new alkaline batteries Operating Temperature 50ºF to 104ºF (10ºC to 40ºC) /15 to 90% RH
/Humidity: Storage Temperature -4ºF to 140ºF (-20ºC to 60ºC) /10 to 95% RH
/Humidity/Air Pressure: /700 - 1060 hPa Main Unit Weight: Approximately 15 1/2 oz. (440 g)
not including batteries Main Unit Dimensions: Approx. 6 1/4" (l) × 4 7/8" (w) × 3 5/16" (h)
(158 mm × 124 mm × 86 mm) Cuff Size: Approximately 6" (w) (152 mm)
Cuff tube 23 5/8" (l) (600 mm) Cuff Circumference: Fits arm circumferences 9" to 17"
(220 mm to 420 mm) Memory: Up to 100 per user Contents: Main Unit, ComFit
TM
Cuff, AC Adapter, 4 “AA” Alkaline Batteries, USB Cable, Instruction Manual, Quick Start Guide, Storage Case
= Type B
NOTE: These specifications are subject to change without notice.
SPECIFICATIONS
Page 60
Manufactured by OMRON HEALTHCARE Co., Ltd.
Made in China
Distributed by:
Omron Healthcare, Inc.
1200 Lakeside Drive Bannockburn, IL 60015 www.omronhealthcare.com
Copyright © 2011 Omron Healthcare, Inc.
Loading...