Omron 10 PLUS BP791IT, 10 Plus, BP791IT, 10+ BP791IT Instruction Manual

10 series Plus
Blood Pressure Monitor
with ComFit
TM
Cuff
Model BP791IT
INSTRUCTION MANUAL
ENGLISH
2
Before Using the Monitor
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Operating the Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Risk of Electrical Shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
Before Taking a Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Operating Instructions
Know Your Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Unit Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Display Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Irregular Heartbeat Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Movement Error Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
USER ID Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Morning Hypertension Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Heartbeat Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Average Value Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Morning Average Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Evening Average Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Cuff Wrap Guide Symbol . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Using the AC Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Battery Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Setting the Date and Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
Setting TruRead
TM
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Applying the Arm Cuff . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
TABLE OF CONTENTS
Taking a Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Calibration Check System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Cuff Wrap Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Using the Guest Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31
Selecting the USER ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Using the USER ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32
Using the Single Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Using the TruRead
TM
Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35
Special Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
Using the Memory Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
Averaging Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .38
To Display the Measurement Values . . . . . . . . . . . . . . . . . . . . . . . .39
Morning and Evening Averages . . . . . . . . . . . . . . . . . . . . . . . . . . . .41
To Display Morning and Evening Averages . . . . . . . . . . . . . . . . . .42
Display Combinations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
To Delete All Values Stored in the Memory . . . . . . . . . . . . . . . . . .44
Downloading Instructions
Installing the Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
Downloading and Installing Microsoft®HealthVault
TM
. . . . . . . . .45
Downloading and Installing Omron Health
Management Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Using the Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
Care and Maintenance
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
Error Indicators and Troubleshooting Tips . . . . . . . . . . . . . . . . . . . . . . . . .55
FCC Statement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
TABLE OF CONTENTS
3
4
Thank you for purchasing the Omron®BP791IT 10 series Plus Automatic Blood Pressure Monitor with ComFit
TM
Cuff.
INTRODUCTION
Fill in for future reference.
DATE PURCHASED: __________________ SERIAL NUMBER: ____________________
Your new blood pressure monitor uses the oscillometric method of blood pressure measurement. This means the monitor detects your blood’s movement through your brachial artery and converts the movements into a digital reading. The monitor stores measurement results for two people and features Morning and Evening Averages. TruRead
TM
allows for three consecutive measurements with timed
intervals for an average reading. The BP791IT comes with the following components:
• Monitor • ComFit
TM
Cuff • AC Adapter
• 4 “AA” Alkaline Batteries • Storage Case • USB Cable
• Instruction Manual printed in English and Spanish
• Quick Start Guide The BP791IT 10 series Plus Automatic Blood Pressure Monitor is
intended for home use.
Please read this instruction manual thoroughly before using the unit. Please keep for future reference. For specific information about your own blood pressure, CONSULT YOUR DOCTOR.
SAVE THESE INSTRUCTIONS
Before Using the Monitor
• Staple your purchase receipt here
• Register your product on-line at www.register-omron.com
5
To assure the correct use of the product basic safety measures should always be followed including the warnings and cautions listed in this instruction manual.
WARNING
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
SAFETY SYMBOLS USED IN THIS INSTRUCTION MANUAL
CAUTION
Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property.
OPERATING THE DEVICE
Contact your physician for specific information about your blood pressure. Self-diagnosis and treatment using measured results may be dangerous. Follow the instructions of your physician or licensed healthcare provider.
DO NOT adjust medication based on measurement results from this blood pressure monitor. Take medication as prescribed by your physician. Only a physician is qualified to diagnose and treat High Blood Pressure.
The monitor is not intended to be a diagnostic device. If battery fluid should get in your eyes, immediately rinse with
plenty of clean water. Contact a physician immediately.
Read all of the information in the instruction manual and any other literature in the box before operating the unit.
SAFETY INFORMATION
OPERATING THE DEVICE (continued)
This device is intended for use in measuring blood pressure and pulse rate in the adult population. Do not use this device on infants or persons who cannot express their intentions.
Read the Special Conditions section (page 37) of the instruction manual if your systolic pressure is known to be more than 220 mmHg. Inflating to a higher pressure than necessary may result in bruising where the cuff is applied.
Operate the device only as intended. Do not use the device for any other purpose.
Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.
Do not use a cellular phone near the device. It may result in an operational failure.
Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit.
Use only 1.5V alkaline batteries with this device. Do not use other types of batteries. This may damage the unit.
SAFETY INFORMATION
6
RISK OF ELECTRICAL SHOCK
Do not plug or unplug the power cord into the electrical outlet with wet hands.
Do not overload power outlets. Plug the device into the appropriate voltage outlet.
CARE AND MAINTENANCE
Do not subject the monitor to strong shocks, such as dropping the unit on the floor.
Do not submerge the device or any of the components in water.
Store the device and the components in a clean, safe location.
Changes or modification not approved by Omron Healthcare will void the user warranty. Do not disassemble or attempt to repair the unit or components.
SAFETY INFORMATION
7
8
BEFORE TAKING A MEASUREMENT
To ensure a reliable reading follow these recommendations:
1. Avoid eating, drinking alcohol, smoking, exercising, and bathing for 30 minutes prior to taking a measurement. Rest for at least 15 minutes prior to taking the measurement.
2. Stress raises blood pressure. Avoid taking measurements during stressful times.
3. Measurements should be taken in a quiet place.
4. Remove tight-fitting clothing from your arm.
5. Sit on a chair with your feet flat on the floor. Rest your arm on a table so that the cuff is at the same level as your heart.
6. Remain still and do not talk during the measurement.
7. Keep a record of your blood pressure and pulse readings for your physician. A single measurement may not provide an accurate indication of your true blood pressure. You need to take and record several readings over a period of time. Try to measure your blood pressure at about the same time each day for consistency.
9
KNOW YOUR UNIT
Main Unit:
Air Jack
Battery Compartment
Start/Stop Button
USER ID Selection Switch
Morning/Evening Average ( ) Button
Memory ( ) Button
Display
AC Adapter Jack
Operating Instructions
Up/Down (
/
) Buttons
Calibration Check System
SET Button
USB Port
KNOW YOUR UNIT
10
Components:
Arm Cuff
Air Tube
Air Plug (Connects to Air Jack)
AC Adapter
Storage Case
Housing
Cord
10 series
Plus
Blood Pressure Monitor
with ComFitTMCuff
Model BP791IT
INSTRUCTION MANUAL
ESPAÑOL
ENGLISH
Quick Start Guide
Instruction Manual
USB Cable
4 AAAlkaline Batteries
11
UNIT DISPLAY
Diastolic Blood Pressure
Systolic Blood Pressure
Movement Symbol
Pulse Display / Memory Number
Date/Time Display
Low Battery Indicator
Deflation Symbol
Morning Average Symbol
Heartbeat Symbol
Irregular Heartbeat Symbol
Evening Average Symbol
Average Value Symbol
Memory Symbol
USER ID Symbol (A or B)
Morning Hypertension Symbol
Week Display
TruRead
TM
Symbol
Blood Pressure Level Indicator
Cuff Wrap Guide
12
IRREGULAR HEARTBEAT SYMBOL ( )
When the monitor detects an irregular rhythm two or more times during the measurement, the Irregular Heartbeat Symbol ( ) will appear on the display with the measurement values.
An irregular heartbeat rhythm is defined as a rhythm that varies by less than 25% from the average rhythm or 25% more than the average rhythm detected while the monitor is measuring the systolic and diastolic blood pressure.
If the irregular heartbeat symbol ( ) displays with your measurement results, we recommend you consult your physician. Follow the directions of your doctor.
MOVEMENT ERROR SYMBOL ( )
The Movement Error Symbol is displayed if you move your body during the measurement. Please remove the arm cuff, and wait 2-3 minutes. Take another measurement, remain still during inflation.
USER ID SYMBOL (
/
)
The USER ID Symbol indicates USER A or USER B as selected by the user to take a measurement or when using the memory function. The USER ID Symbol is not displayed when using the Guest Mode to take a measurement.
Normal Heartbeat
Irregular Heartbeat
Pulse
Blood
pressure
Pulse
Blood
pressure
Short Long
DISPLAY SYMBOLS
Internationally recognized guidelines for upper limit of normal home blood pressure readings are as follows:
Home Guideline for Upper Limit of Normal BP
Systolic Blood Pressure 135 mmHg Diastolic Blood Pressure 85 mmHg This is a general guideline because blood pressure depends on
age and morbidity. A lower home blood pressure goal may be recommended for certain patients, including diabetic patients, pregnant women, and patients with renal failure.
The monitor is not intended to be a diagnostic device.
MORNING HYPERTENSION SYMBOL ( )
The Morning Hypertension Symbol is displayed if the morning average reading for a week is above 135 for the Systolic Blood Pressure value and/or 85 for the Diastolic Blood Pressure value when viewing the Morning Averages and the Evening Averages in the memory.
Omron Healthcare recommends you contact your physician if the MORNING HYPERTENSION SYMBOL appears on the display with your measurement values.
DISPLAY SYMBOLS
13
HEARTBEAT SYMBOL ( )
The Heartbeat symbol flashes on the display at every heartbeat during the measurement.
AVERAGE VALUE SYMBOL ( )
The Average Value Symbol is displayed when you press the memory button. The most recent average reading appears on the display screen.
MORNING AVERAGE SYMBOL ( )
The Morning Average symbol is displayed when viewing Morning Averages using the Memory Function.
EVENING AVERAGE SYMBOL ( )
The Evening Average symbol is displayed when viewing Evening Averages using the Memory Function.
CUFF WRAP GUIDE SYMBOL ( / )
When the cuff is wrapped around the arm correctly, ( ) is displayed while taking a measurement or using the memory function. If the cuff is
not wrapped around the arm correctly, ( ) is displayed.
DISPLAY SYMBOLS
14
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS
NOTES: • Use only the authorized Omron AC Adapter that came with
this monitor.
• We recommend you install the batteries even if the AC Adapter is used. If no batteries are installed, you may need to reset the date and time if the AC Adapter is disconnected. The measurement results will not be deleted.
CAUTION
Use only Omron authorized parts and accessories. Parts and accessories not approved for use with the device may damage the unit.
USING THE AC ADAPTER
15
- DANGER -
TO REDUCE THE RISK OF
FIRE OR ELECTRIC SHOCK,
CAREFULLY FOLLOW THESE INSTRUCTIONS.
For connection to a power supply not in the U.S.A., use an attachment plug adapter of the proper configuration for the power outlet.
The power unit (AC Adapter) is intended to be correctly oriented in a vertical or floor mount position.
TO CONNECT THE AC ADAPTER
Insert the AC Adapter Plug into
the AC Adapter Jack on the back side of the monitor as illustrated.
Plug the AC Adapter into a 120V
AC outlet (60 cycles).
TO DISCONNECT THE AC ADAPTER
Hold the Housing to remove the AC Adapter from the electrical
outlet.
Remove the AC Adapter plug from the monitor.
WARNING
Do not plug or unplug the power cord into the electrical outlet with wet hands.
WARNING
Do not overload power outlets. Plug the device into the appropriate voltage outlet.
USING THE AC ADAPTER
16
Housing
Cord
1. Remove the battery cover by pulling the hook up while pushing it in the direction of the arrow.
2. Install 4 “AA” size batteries so the + (positive) and - (negative) polarities match the polarities of the battery compartment as indicated.
3. Replace the battery cover.
BATTERY INSTALLATION
17
Battery Cover
BATTERY REPLACEMENT
When the Low Battery Indicator appears on the display screen turn the monitor off and remove all the batteries. Replace with four new batteries at the same time. Longlife alkaline batteries are recommended.
WARNING
If battery fluid should get in your eyes, immediately rinse with plenty of clean water. Contact a physician immediately.
NOTES: • Turn the unit off before replacing the batteries. If the
batteries are removed while the unit is still on, the date and time will be reset to that of the previous use. However, the measurement results are not deleted.
• When the batteries are replaced, you may need to reset the date and time. If "-:--" appears on the display, refer to “Setting the Date and Time”.
• The supplied batteries may have a shorter life.
CAUTION
Dispose of the device, components and optional accessories according to applicable local regulations. Unlawful disposal may cause environmental pollution.
BATTERY INSTALLATION
18
Low Battery Indicator
Loading...
+ 42 hidden pages