c. Connect to the RJ-45/48 connector on the iConverter T1/E1 converter via a Category 3
or better cable (Category 5 is recommended), and attach the other end to the network equipment.
d. Connect an appropriate multimode or single-mode fiber cable to the fiber port of
the installed module. It is important to ensure that the transmit (TX) is attached to the receive side of the device at the other end and the receive (RX) is attached to the transmit side. Single-fiber (SF) media converter models operate in pairs. The TX wavelength must match the RX wavelength at the other end and the RX wavelength must match the TX wavelength at the other end.
CABLE SPECIFICATIONS:
UTP Cable for T1 and E1
Gauge 22 to 24 AWG Impedance 100 ohms +/- 10% Impedance Characteristic 2.6dB/100M @ 1Mhz Maximum Distance T1 6,000 ft E1 8,000 ft
3) VERIFY OPERA TION
Once the module has been installed and configured per steps 1 and 2, verify the module is operational by viewing the LED indicators.
The Power LED indicates the module is receiving power. The Fiber Optic link LED indicates the fiber optic connection has been established. The UTP LED indicates a T1/E1 signal has been detected. If the Fiber Optic LED is blinking, the port is receiving an all 1s signal. This will occur
if the UTP port is not connected.
LED Function
"Legend"
Power "Pwr"
Fiber Optics "F/O Lk"
Test "Tst"
UTP "UTP Lk"
Color OFF State ON State
Amber No power Module has power
Green No Fiber Link
Green Normal
Green No UTP Li nk
Omnitron Systems Technology * 140 Technology Dr. #500 * Irvine, CA 92618
949.250.6510 tel * 949.250.6514 fax * www.omnitron-systems.com
On: Fiber signal detected
Blinking: All ones received
On: Loop or All ones Test Mode
Blinking: FOT Received - Local
Fast Blinking: FOT Recei ved - Remote
On: UTP signal detected
Blinking: All ones received
Form 040-08700-001 J 7/08
iConverter® T1/E1 Standalone Module USER MANUAL
The iConverter T1/E1 media converter provides standard T1 (1.544Mbps) or E1 (2.048Mbps) copper to fiber conversion and can be used to extend the demarcation point between service provider and networking equipment. T1/E1 media converters operate in pairs, extending distances over fiber , which improves noise immunity, quality
of service, intrusion protection and network security.
The T1/E1 supports Small Form Pluggable (SFP) transceivers, enabling adaptability to different fiber types, distances and wavelengths, providing maximum flexibility across a variety of network architectures and topologies.
INSTALLATION PROCEDURE
1) Configure DIP-Switches
2) Install Standalone Module and Connect Cables
3) Verify Operation
1) CONFIGURE DIP-SWITCHES FRONT PANEL DIP-SWITCHES
SW1 - LOCAL DUAL LOOP-BACK “LOOP”
When this DIP-switch is set to the “Loop” position, it sets the to a dual loop-back mode (see Figure B) on both the fiber and copper connections. By returning the DIP­switch to the “Norm” position, the unit resumes normal operation.
SW2 - FIBER OPTIC TEST “FOT”
This DIP-switch will allow the entire fiber segment to be tested at either of the iConverter T1/E1 converters without having to set DIP-switches on both units. When this DIP-switch is set to “FOT”, the local unit (the unit with the DIP-switch in the “FOT”
Figure A: DIP-Switch Location
position) is switched into local loop­back mode. In addition to the local loop-back mode of operation, the fiber TX port is further encoded to carry a remote loop-back protocol. This remote loop-back protocol sets the remote unit at the other end of the fiber link to a remote loop-back mode of operation and returns a signal to the local unit (see Figure C). A fast blinking “Tst” LED on the local unit and a slow blinking “Tst” LED on the remote unit shows confirmation that the fiber segment is communicating properly between devices. By returning the DIP-switch to the “Norm” position, the units resumes normal operation.
iConverter T1/E1 converter
Figure B: Dual Loopback Mode
Line Type Port Type Distance
T1 DSX-1 RJ-45/48 0' to 133' T1 DSX-1 RJ-45/48 133' to 266' T1 DSX-1 RJ-45/48 266' to 399' T1 DSX-1 RJ-45/48 399' to 533' T1 DSX-1 RJ-45/48 533' to 655'
DIP-Switch Position
1234
LLLL
LLLK
LLKL
LLKK
LKLL
Figure C: Fiber Optic Test Mode
SW3 - FORCE 1S TO FIBER “FO1”
When this DIP-switch is set to the “FO1” position, an “all ones” pattern is inserted into the data stream being transmitted out of the fiber port on the T1/E1 converter. Data being received on the coax or twisted pair is disabled and data being received on the fiber is passed through to the coax or twisted pair side. A blinking “Tst” LED on the remote T1/E1 shows confirmation that the fiber segment is communicating properly between the devices. By returning the DIP-switch to the “Norm” position, the unit resumes normal operation.
SW4 - FORCE 1S TO COAX OR UTP “CU1”
When this DIP-switch is set to the “Cu1” position, an “all ones” pattern is inserted into the data stream being transmitted out of the coax or twisted pair port on the T1/E1 converter. Data being received on the fiber will be disabled and data being received on the coax or twisted pair is passed through to the fiber side. A blinking “Tst” LED on the remote T1/E1 shows confirmation that the Coax or UTP segment is communicating properly between the devices. By returning the DIP-switch to the “Norm” position, the unit resumes normal operation.
SW1 AND SW2 - AMI/B8ZS/HDB3 MODE
B8ZS (T1) or HDB3 (E1) is the default line encoding mode of operation. To select AMI mode enable both the Local Dual Loop-back “Loop” and Fiber Optic Test “FOT” DIP-switches on the front of the module.
PUSH BUTTON - MANUAL CROSSOVER “= / X”
The Manual Crossover “= / X” button located on the front panel is used to eliminate the need for crossover and custom cables when connecting devices to the RJ-45/48 port. When the button is in the out “=” position, the port is configured for a straight-through cable. When the button is in the in “X” position, the port is configured for a crossover cable. The twisted pair connection requires two active pairs in a T1/E1 environment. The active pairs are pins 1 & 2 and pins 4 & 5. Only dedicated wire pairs should be used for the active pins.
DIP-SWITCH BANK 1
BOARD MOUNTED DIP-SWITCH SETTINGS: T1/E1 Copper Line Configuration Settings:
The T1/E1 copper line codes and line lengths are configured using board mounted DIP-switches.
T1 DS1 RJ-45/48 0 dB T1 DS1 RJ-45/48 -7.5 dB T1 DS1 RJ-45/48 -15 dB T1 DS1 RJ-45/48 -22.5 d B
E1 120 ohm RJ-45/48 Standard E1 120 ohm RJ-45/48 Extended
LLLL
LKLK
LKKL
LKKK
KLLK
KLKK
2) INST ALL ST ANDALONE MODULE AND CONNECT CABLES
a. The T1/E1 Converter is available in wall-mount models. For wall-mounting, attach
the unit to a wall, backboard or other flat surfaces. To power the unit using the AC/DC adapter, connect the AC/DC adapter to the AC
outlet. Then connect the barrel plug at the end of the wire on the AC/DC adapter to the 2.5mm DC barrel connector (center-positive) on the chassis. Confirm that the unit has powered up properly by checking the power status LED located on the front of the unit.
To power the unit using a DC power source, prepare a power cable using a two­conductor insulated wire (not supplied) with a 14 AWG gauge minimum. Cut the power cable to the length required. Strip approximately 3/8 of an inch of insulation from the power cable wires. Connect the power cables to the standalone unit by fastening the stripped ends to the DC power connector.
Connect the power wires to the DC power source. The Power LED should indicate the presence of power.
WARNING: Note the wire colors used in making the positive and negative connections. Use the same color assignment for the connection at the DC power source.
NOTE: If mounting with a safety ground attachment, use the safety ground screw at the rear of the unit.
b. When using the SFP model (8719-0 or 8759-0), insert the SFP Fiber transceiver
into the Port 1 SFP receptacle on the T1/E1 converter (see the SFP Data Sheet 091-17000-001 for supported transceivers).
NOTE: The release latch of the SFP Fiber transceiver must be in the closed (up) position before insertion.