Omnitron Systems Technology E1, T1 User Manual

FlexPointTM T1/E1 Copper to Fiber
Converters
User Instructions
Description:
The FlexPoint T1/E1 connects T1 and E1 devices, such as PBXs, CSUs and routers, via multimode (MM) or single-mode (SM) fiber. Designed to extend the standard T1/E1 twisted p air or Coax network distances over fiber, this converter provides protection from environmental noise and effectively increases high-speed network reliability. The following models are described here.
Model # Fiber Type Max Distance
4470/90-x MM, SC, 1310nm 5km 4471/91-x SM, SC, 1310nm 30km 4472/92-x MM, ST , 1310nm 5km 4473/93-x SM, ST, 1310nm 30km 4474/94-x SM, SC, 1310nm, LH 60km
Power Options (-x):
-0 No power adapter included (chassis module)
-1 110 Volt / 60 Hz
-2 110-230 Volt / 50 Hz
Mounting Options
4380 FlexPoint Wall-Mounting Hardware Kit 4384 FlexPoint 18 to 72VDC Stand-Alone Power Supply 4381 FlexPoint DC Converter Wall-Mounting Kit (for 4384) 4385 FlexPoint 14-Unit 48VDC Power-Redundant Chassis 4392 FlexPoint 5-Unit Rack-Mounting Shelf 4395 FlexPoint 14-Unit AC Power-Redundant Chassis
Power Adapter Notice
1. When Using in a stand-alone configuration, this product is intended to be and must be used only with a Listed Direct Plug-In Power Unit marked “Class 2” and rated at 9VDC, 1 Amp.
2. This product should always be used only with Omnitron Supplied Power Unit model numbers 9113-PS or 91 15-PS.
WARNING!
Before inserting the Power Adapter, verify that the
power on the unit is appropriate for your AC line
voltage source.
Mounting instructions:
The FlexPoint Fiber Converter can be solo-mounted using a wall-mounting kit, or rack-mounted using a 5-unit shelf, or a high-density FlexPoint 14-Unit Power-Redundant Chassis.
Fiber Optic Cable Attachment:
Connect the fiber cables between the FlexPoint T1/E1 converters. The transmit (Tx) must attach to the receive side and the receive (Rx) must attach to the transmit side.
Note: Use fiber cables that are compliant with the specifications that are outlined in fiber cable specifications.
Copper Cable Attachment:
RJ-45/RJ-48 T1/E1 connector
Connect to the RJ-45/48 connector on the FlexPoint T1/ E1 converter via a category 3 or better cable (Category 5 is recomended) and attach the other end to the network
equipment. (The twisted pair connection requires two active pairs in a T1/E1 environment. The active pairs are pins 1&2 and pins 4&5. Only dedicated wire pairs should be used for the active pins.) Set the UTP DCE / DTE switch for the RJ-45/48 port to the appropriate setting.
Note: Use copper cables that are compliant with the specifications that are outlined in copper cable specifications.
Coax E1 Connector
Attach the BNC to the FlexPoint T1/E1 converter and attach the other end of the BNC to the network equipment.
Note: Use copper cables that are compliant with the specifications that are outlined in copper cable specifications.
Switch Settings:
UTP DCE/DTE setting
The UTP DCE/DTE switch is used to eliminate the need for crossover and custom cables to connect devices together when using the RJ-45/48 port. Se t th is s wit ch t o DC E to u se a straight-through cable and to DTE when a crossover-cable would be required.
Twisted Pair #1
Twisted Pair #2
DCE
TTIP
TRING
RTIP
RRING
Twisted Pair #1
Twisted Pair #2
RTIP
1 2
RRING
TTIP
4 5
TRING
DTE
RTIP
RRING
TTIP
TRING
TTIP
TRING
RTIP
RRING
1 2
4 5
T1/E1 Copper line configuration settings
The T1/E1 copper line codes and line lengths are configured using dip switches located on the side of the FlexPoint T1/E1 media converter.
Line Type Port Type Distances Switch Positions
T1 DSX-1 RJ-45/48 0’ - 133’ T1 DSX-1 RJ-45/48 133’ - 266’ T1 DSX-1 RJ-45/48 266’ - 399’ T1 DSX-1 RJ-45/48 399’ - 533’ T1 DSX-1 RJ-45/48 533’ - 655’
T1 DS-1 RJ-45/48 0 dB T1 DS-1 RJ-45/48 -7.5 dB T1 DS-1 RJ-45/48 -15.0 dB T1 DS-1 RJ-45/48 -22.5 dB
E1 75 Ω Coax/BNC Standard E1 120 Ω RJ-45/48 Standard E1 75 Ω Coax/BNC Extended E1 120 Ω RJ-45/48 Extended
1 2 3 4
LL
LL
LL
L
L
L
LL
LL
LL
LL
LL
LL
L
L
L
LL
LL
LL
LL
LL
KK
L
L
K
LL
LL
KK
LL
LL
KK
L
L
K
LL
LL
KK
LL
KK
LL
L
K
L
LL
KK
LL
LL
LL
LL
L
L
L
LL
LL
LL
LL
KK
LL
L
K
L
LL
KK
LL
LL
KK
KK
L
K
K
LL
KK
KK
LL
KK
KK
L
K
K
LL
KK
KK
KK
LL
LL
K
L
L
KK
LL
LL
KK
LL
LL
K
L
L
KK
LL
LL
KK
LL
KK
K
L
K
KK
LL
KK
KK
LL
KK
K
L
K
KK
LL
KK
LL
L
LL KK
K
KK LL
L
LL KK
K
KK LL
L
LL
LL
L
LL KK
K
KK LL
L
LL KK
K
KK
LL
L
LL KK
K
KK LL
L
LL KK
K
KK
Operational switch settings and functions
The following operational switches located on the front of the FlexPoint T1/E1 converter are to assist in installation and fault isolation.
Local Dual Loop Back
Normal
Remote & Local Loop Back Force 1’s to Fiber Force 1’s Copper
Local loop-back (L/LB)
This switch will set the FlexPoint T1/E1 converter in a loop-back mode on both the fiber and copper connections. By returning the switch to the normal position the unit will resume to normal operation.
Cu-Rx
Cu-Tx
Loopback Enabled
FO-Tx
FO-Rx
Remote loop-back (R+L/LB)
This switch will allow the entire fiber segment to be tested at either of the FlexPoint T1/E1 converters without having to set switches on both units. When set in this mode the local unit is switched to a local loop-back mode. The fiber Tx port will be further encoded to carry a remote loop-back protocol. This remote loop-back will set the far end FlexPoint T1/E1 converter to remote loop-back mode and return a signal to the sending unit. An LED on the local and remote FlexPoint T1/E1 converters will show a confirmation that the fiber segment is communicating properly between devices. By returning the switch to the normal position it will return to normal operation.
Cu-Rx
Cu-Tx
Remote Loop Request
Over Fiber
FO-Tx
FO-Rx
FO-Rx
FO-Tx
Cu-Tx
Cu-Rx
User Warranty Registration
Omnitron Systems Technology, Inc.
140 Technology Drive, #500
Irvine, CA 92618, USA
Fax: (949) 250-6514
Please register on-line @ http://www.omnitron-systems.com or complete both sides
and mail or fax this registration form to:
Name: _________________________________________________
______________________________________________
Address: ______________________________________________
Please complete both sides of this form
City: ___________________ State: _______ Zip Code: ________
Country: _______________________________________________
Phone: ____________________ Fax: _______________________
E-mail:_________________________________________________
Local loop-back and Remote loop-back
When both Local and Remote Loop-back are set to the Normal position, the FlexPoint T1/E1 uses the default B8ZS data format. When both switches are turned to their On position, it uses the AMI data format.
Transmit/force 1’s to fiber
This switch is used to insert an “all ones” pattern into the data stream being transmitted out of the fiber port on the FlexPoint T1/E1 converter. Data being received on the coax or twisted pair will be disabled and data being received on the fiber is passed through to the coax or twisted pair side. By returning the switch to the normal position the unit will resume to normal operation.
Transmit/force 1’s to Coax or UTP
This switch is used to insert an “all ones” pattern into the data stream being transmitted out of the coax or twisted pair on the FlexPoint T1/E1 converter. Dat a being received on the fiber will be disabled and data being received on the coax or twisted pair is passed through to the fiber side. By returning the switch to the normal position the unit will resume to normal operation.
Alarm Relay Contacts
The FlexPoint T1/E1 features dry relay contacts for optionally connecting the it into a separate T1/E1 alarm circuit. The relay closes when a loss of power or when signal detect is lost to the copper or fiber connection.
Relay
Operational rating on relay pins 3 & 6: 0-220VDC max 2A
RJ-45/RJ-48
3
6
LED Indicators
LED Color Status Description Power:
Yellow On Power applied
Fiber:
Green Off No signal detect
UTP/Coax:
Green Off No signal detect
Test:
Green Off Normal operation
On Signal detect Blink All ones received
On Signal detect Blink All ones received
On L/LB or All 1’s Test mode Blink R+L/LB Received master Fast Blink R+L/LB Received slave
Fiber Cable Specifications:
Multimode
Cable: 50/125, 62.5/125, 100/140 μm Wavelength: 1310nm Max Distance: 5k m
Singlemode
Cable: 9/125 μm Wavelength: 1310nm Max Distance: 30km
Singlemode long-haul
Cable: 9/125 μm Wavelength: 1310nm Max Distance: 60km
Copper Cable Specifications:
Twisted-Pair cable for T1
Gauge 22 to 24 AWG Impedance 100 Impedance characteristic 2.6 dB / 100m @ 1.0 MHz Maximum distance 6,000 ft
Ω + 10%
Twisted-Pair cable for E1
Gauge 22 to 24 AWG Impedance 120 Impedance characteristic 2.6 dB / 100m @ 1.0 MHz Maximum distance 8,000 ft
Ω + 10%
Coax cable for E1
Gauge 22 to 24 AWG Impedance 75 Impedance characteristic 2 dB / 100m @ 1.0 MHz Maximum distance 8,000 ft
For product specifications refer to the product data sheet.
Ω + 10%
Technical Support:
For help with this product, contact our Tech. Support: Phone: (949) 250-6510 Fax: (949) 250-6514 Address: Omnitron Systems Technology, Inc.
E-mail: support@omnitron-systems.com URL: http://www.omnitron-systems.com
140 Technology Drive, #500 Irvine, CA 92618 USA
Warning
The operating description in this Instruction Manual is for use by qualified personnel only. To avoid electrical shock, do not perform any servicing of this unit other than that contained in the operating instructions, unless you are qualified and certified to do so by Omnitron Systems T echnology , Inc.
Caution
All user-required operations can be performed without opening the unit. Never attempt to open or remove the cover or tamper with the unit.
Warranty
This product is warranted to the original purchaser against defects in material and workmanship for a period of TWO YEARS from the date of shipment. A LIFETIME warranty may be obtained by the original purchaser by REGISTERING this product with Omnitron within 90 days from the date of shipment. TO REGISTER, COMPLETE AND MAIL OR FAX THE REGISTRATION PORTION OF THIS INSTRUCTION MANUAL TO THE INDICATED ADDRESS. Or you may register your product on the Internet at http://www.omnitron­systems.com. During the warranty period, Omnitron will, at its option, repair or replace a product which is proven to be defective. For warranty service, the product must be sent to an Omnitron designated facility, at Buyer’s expense. Omnitron will pay the shipping charge to return the product to Buyer’s designated US address using Omnitron’s standard shipping method.
Limitation of Warranty
The foregoing warranty shall not apply to defects resulting from improper or inadequate use and/or maintenance of the equipment by Buyer, Buyer-supplied equipment, Buyer-supplied interfacing, unauthorized modifications or tampering with equipment (including removal of equipment cover by personnel not specifically authorized and certified by Omnitron), or misuse, or operating outside the environmental specification of the product (including but not limited to voltage, ambient temperature, radiation, unusual dust, etc.), or improper site preparation or maintenance.
No other warranty is expressed or implied. Omnitron specifically disclaims the implied warranties of merchantability and fitness for any particular purpose.
Exclusive Remedies
The remedies provided herein are the Buyer’s sole and exclusive remedies. Omnitron shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any legal theory.
Form: 040-04470-002D 11/07
User Warranty Registration
and return this form to Omnitron Systems.
Please register on-line at http://www.omnitron-systems.com or complete both sides
Model:_________________________________________________
Serial Number: ______________ Purchase Date: ______________
Purchased From: _________________________________________
Address: ______________________________________________
City: ___________________ State: _______ Zip Code: ________
Country: _______________________________________________
Please complete both sides of this form
______________________________________________________
______________________________________________________
Comments and Suggestions: _______________________________
Loading...