NOTES:
Omnitron Systems Technology, Inc. 1
OmniRepeaterTM 400
Systems AS400/3X 5250
and 5250 Express Twinax
Fiber Converter
User ’s Manual
27 Mauchly #201, Irvine, CA 92618; (949) 250-6510, Fax: (949) 250-6514
Document #040-02651-001
2 Omnitron Systems Technology, Inc.
Omnitron Systems Technology, Inc. 7
SAFETY CONSIDERATIONS
Warning
The instructions in this User’s Manual are for use by qualified personnel only. To avoid electrical
shock, do not perform any servicing of this unit or its accessories (such as power units) other
than that contained in the operating instructions, unless you are qualified and certified to do so by
Omnitron Systems T echnology , Inc.
Caution
All user-required operations can be performed without ever opening the unit’s cover. Never attempt
to open or remove the unit’s cover or tamper with its power units (other than plugging and unplugging
them as specified in the operating instructions).
Line Voltage
Before Connecting the Power units to the line voltage, make sure that the voltage of the power
source (wall outlet) matches the voltage specified on the power units.
Warranty
This
OST
workmanship for a period of
be extended to
within 90 days from the date of shipment. TO REGISTER, PLEASE COMPLETE AND MAIL OR
FAX BACK THE REGISTRATION CARD. During the warranty period,
repair or replace a product which is proven to be defective.
For warranty service/repair, the product must be sent to an
prepaid by the Buyer.
(using
The foregoing warranty shall not apply to defects resulting from improper or inadequate use and/
or maintenance of the equipment by Buyer, Buyer-supplied equipment, Buyer-supplied interfacing,
unauthorized modifications or tampering with equipment (including removal of equipment cover
by personnel not specifically authorized and certified by
environmental specification of the product (including but not limited to voltage, ambient temperature,
radiation, unusual dust, etc.), or improper site preparation or maintenance.
No other warranty is expressed or implied.
merchantability and fitness for any particular purpose.
The remedies provided herein are the Buyer’s sole and exclusive remedies.
liable for any direct, indirect, special, incidental, or consequential damages, whether based on
contract, tort, or any legal theory.
product is warranted to the original purchaser against defects in material and
LIFETIME
OST’
s standard shipping method).
TWO YEARS
by the original purchaser if the product is
OST
will pay postage/shipping charges to return the product to Buyer
from the date of shipment. This warranty period may
OST
Limitation of Warranty
OST
OST
specifically disclaims the implied warranties of
Exclusive Remedies
REGISTERED
OST
will, at its option,
designated repair facility, shipment
), misuse, operating outside the
OST
Form:040-02651-001 07/00
shall not be
with
OST
SPECIFICATIONS
n Protocol: IBM 5250 and 5250 Express for systems AS/400 and 3X
n Devices Supported: All twinax/IBM compatible devices (terminals and
printers)
n Interface:
Link: One (1) Twinax, One (1) Fiber or
One (1) Rj11/45, One (1) Fiber
Port: One (1) Twinax or
One (1) Rj11/45
(RJ11 pins 3-4, RJ45 pins 4-5 are standard)
n Cable Types:
Twinax: IBM 7362229 or equivalent
UTP: Category 3 (EIA/TIA 568) or higher
(shorter distance @ lower grade)
n Data Rate:
Standard 5250: 1 Mbps -2%, +4%
5250 Express: 1 or 2 Mbps -2%, +4%
n Supported Distances:
Host/Device to Mux:
Twinax: 5,000 ft.
UTP: 3,000 ft.
Multimode fiber: 15,000 ft.
Single-mode fiber: 30,000 ft.
n Physical Dimensions:
Rackmount: W:19.0”xD:6.0”xH:1.75”
T abletop: W:17.5”xD:6.0”xH:1.75”
n Weight: 7 lbs.
n Power: 115 or 230 VAC, 100/50 mA
n Temperature:
Operating: 0° to 40°C
Storage: -40° to 75°C
Humidity: Up to 90% (non-condensing)
TECHNICAL SUPPORT
For assistance in installing this product, contact Omnitron’s Technical Support
Department.
Phone: (949) 250-6510
Fax: (949) 250-6514
Address: Omnitron Systems Technology, Inc.
27 Mauchly #201
Irvine, CA 92618, USA
Email: support@omnitron-systems.com