Omnitron Systems Technology OmniConverter FPoE/SL User Manual

OmniConverter
FPoE/SL
User Manual
140 Technology Dr., #500 Irvine, CA 92618 USA
Phone: (949) 250-6510; Fax: (949) 250-6514
Warning
To avoid electrical shock, do not perform any servicing of this product other than
that contained in the operating instructions, unless you are qualied and certied
to do so by Omnitron Systems Technology, Inc.
Caution
All user-required operations can be performed without opening the chassis. Never attempt to open or remove the cover or tamper with the chassis. There are no user replaceable or serviceable parts in this unit. Equipment is not intended to be installed and used in a place (home, school, or public area) accessible to the general population.
Warranty
This product is warranted to the original purchaser against defects in material and workmanship for a period of TWO YEARS from the date of shipment. A LIFETIME warranty may be obtained by the original purchaser by REGISTERING this product with Omnitron within 90 days from the date of shipment. You may register your product on the Internet at http://www.omnitron-systems.com. During the warranty period, Omnitron will, at its option, repair or replace a product which is proven to be defective.
For warranty service, the product must be sent to an Omnitron designated facility, at Buyer’s expense. Omnitron will pay the shipping charge to return the product to Buyer’s designated US address using Omnitron’s standard shipping method.
Limitation of Warranty
The foregoing warranty shall not apply to defects resulting from improper or inadequate use and/or maintenance of the equipment by Buyer, Buyer-supplied
equipment, Buyer-supplied interfacing, unauthorized modications or tampering with equipment (including removal of equipment cover by personnel not specically
authorized and certified by Omnitron), or misuse, or operating outside the
environmental specication of the product (including but not limited to voltage,
ambient temperature, radiation, unusual dust, etc.), or improper site preparation
or maintenance. No other warranty is expressed or implied. Omnitron specically disclaims the implied warranties of merchantability and tness for any particular
purpose.
Exclusive Remedies
The remedies provided herein are the Buyer’s sole and exclusive remedies. Omnitron shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any legal theory.
Page 2
OmniConverter FPoE/SL
User Manual
Product Overview
The OmniConverter FPoE/SL media converters with multi-port options provide
10/100BASE-T UTP to 100BASE-FX ber conversion and function as Power-over­Ethernet (PoE) Power Sourcing Equipment (PSE). Port congurations are available
in single or dual UTP and SFP ports.
OmniConveter FPoE/SL
Equipment that provides DC power over twisted-pair cable is known as Power Sourcing Equipment (PSE). Equipment that is powered over twisted-pair cable is known as a Powered Device (PD).
The OmniConverter FPoE/SL supports IEEE 802.3af PoE standard and provides up to 15.4W of DC power to each PD.
Installation Procedure
1) Congure DIP-switches
2) Apply AC Power
3) Apply DC Power
4) Connect Cables
5) Verify Operation
1) Congure DIP-switches
DIP-switches are located on the side of the OmniConverter module. The DIP-switches
are used to congure ports, link modes and PoE/PSE options.
Page 3
DIP-switch Bank Locations
The table below provides a description of each DIP-switch position and function.
Switch 1 Fiber, 1 UTP 1 Fiber, 2 UTP 2 Fiber, 1 UTP 2 Fiber, 2 UTP
1 Port 1 Duplex Mode Port 1 Duplex Mode Port 1 Duplex Mode Port 1 Duplex Mode
2 N/A N/A Port 2 Duplex Mode Port 2 Duplex Mode
3
Port 2 UTP
AUTO/MAN
Port 2 UTP
AUTO/MAN
Port 3 UTP
AUTO/MAN
Port 3 UTP
AUTO/MAN
4
Port 2 UTP Speed
(Only in MAN mode)
Port 2 UTP Speed
(Only in MAN mode)
Port 3 UTP Speed
(Only in MAN mode)
Port 3 UTP Speed
(Only in MAN mode)
5
Port 2 UTP Duplex
(Only in MAN mode)
Port 2 UTP Duplex
(Only in MAN mode)
Port 3 UTP Duplex
(Only in MAN mode)
Port 3 UTP Duplex
(Only in MAN mode)
6 Pause Capability Pause Capability Pause Capability Pause Capability
7 UTP Port 2 PoE/PSE UTP Port 2 PoE/PSE UTP Port 3 PoE/PSE UTP Port 3 PoE/PSE
8 N/A UTP Port 3 PoE/PSE N/A UTP Port 4 PoE/PSE
9 UTP Port 2 Alt A/B UTP Port 2 Alt A/B UTP Port 3 Alt A/B UTP Port 3 Alt A/B
10 N/A UTP Port 3 Alt A/B N/A UTP Port 4 Alt A/B
11 Large Cap Detection Large Cap Detection Large Cap Detection Large Cap Detection
12 Link Mode Selection Link Mode Selection Link Mode Selection Link Mode Selection
13 Link Mode Selection Link Mode Selection Link Mode Selection Link Mode Selection
14 PSE Reset PSE Reset PSE Reset PSE Reset
15 N/A N/A Redundant Fiber Link Redundant Fiber Link
16 N/A N/A Return to Port 1 Return to Port 1
DIP-switch Denitions
SW1 and SW2: F/O Duplex “FDX/HDX” DIP-switch
The OmniConverter supports 100BASE-FX SFPs and xed ber transceivers. These DIP-switches are used to congure the ber duplex mode. Setting these
DIP-switches to the Up “HDX” position facilitates a connection that supports Half-Duplex. Setting these DIP-switches to the Down “FDX” position facilitates a connection that supports Full-Duplex operation.
Page 4
SW3, SW4 and SW5 UTP Conguration DIP-Switches
SW3 UTP
AN/MAN
SW4 UTP
100/10
SW5 UTP
FDX/HDX
UTP Mode of Operation
AN 100 FDX
The UTP port is set to auto-negotiation with the following modes advertised: 100FDX, 100HDX, 10FDX, 10HDX
AN 100 HDX
The UTP port is set to auto-negotiation with the following modes advertised: 100HDX, 10FDX, 10HDX
AN 10 FDX
The UTP port is set to auto-negotiation with the following modes advertised: 10FDX, 10HDX
AN 10 HDX The UTP port is set to auto-negotiation advertising 10HDX.
MAN 100 FDX The UTP port is set to manual negotiation and is forced to 100FDX.
MAN 100 HDX The UTP port is set to manual negotiation and is forced to 100HDX.
MAN 10 FDX The UTP port is set to manual negotiation and is forced to 10FDX.
MAN 10 HDX The UTP port is set to manual negotiation and is forced to 10HDX.
UTP Port Conguration Matrix
SW6 - Pause “On/Off” DIP-Switch
In auto-negotiation mode, setting this DIP-switch to the Up “On” position allows the unit to advertise Symmetrical and Asymmetrical Pause capability. In auto-negotiation mode, setting the DIP-switch to the Down “Off” position allows the unit to advertise no Pause capability. In the manual mode, this DIP-switch determines the Pause behavior.
SW7 - Power Sourcing Function, UTP Port
The OmniConverter automatically detects the attached PD and provides the equipment with the necessary power.
This DIP-switch controls the power sourcing function for Port 2 on the single-ber models and Port 3 on all other models (see DIP-switch Denition table on page
4). When this DIP-switch in the Down “On” position, the power sourcing function is enabled. When the DIP-switch is in the Up “Off” position, the power sourcing function is disabled.
Switch Position Description DOWN UP
7 UTP Port 2 or 3 PoE/PSE Enabled (ON) Disabled (OFF)
8 UTP Port 3 or 4 PoE/PSE Enabled (ON) Disabled (OFF)
Power Sourcing Function
SW8 - Power Sourcing Function, UTP Port
This DIP-switch controls the power sourcing function for the 2nd UTP port on the 2
UTP port models (see DIP-switch Denition table on page 4). When this DIP-switch
in the Down “On” position, the power sourcing function is enabled. When the DIP-switch is in the “Off” UP position, the power sourcing function is disabled.