Omnitron Systems Technology xFF, OC3FF, 1000FF, 100FF User Manual

iConverter
®
100FF , OC3FF , OC12FF, 1000FF and xFF
Fiber-to-Fiber Converter User Manual
Port 1 (P1)
Port 2 (P2)
OVERVIEW:
The iConverter FF modules are fiber-to-fiber media converters providing single-mode (SM) to multimode (MM), dual fiber to single-fiber, wavelength conversion and fiber extension. Fixed-fiber models are available for Ethernet, Fast Ethernet, Gigabit Ethernet and SONET/SDH applications. Small Form Pluggable (SFP) model is protocol transparent and also supports Fibre Channel.
iConverter FF media converters can be used in an
The unmanaged or managed fashion. When unmanaged, they can be installed in a chassis without a Network Management Module (NMM). T o be managed, an NMM or a media converter with built-in management must be installed in the same chassis.
Page 1 Page 2 Page 3 Page 4 Page 5 Page 6
Connector
ST/ST SC/SC
8620-1 8622-1
8620-2 8622-2
- 8622-3
ST/SC SC/SC
8630-1 8634-1
8631-1 8635-1
8630-2 8634-2
8631-2 8635-2
8632-1 8636-1
8633-1 8637-1
8632-2 8636-2
8633-2 8637-2
iConverter
100FF Dual Fiber Modules
Fiber Type
Distances
(Port 1
(Port 1
Port 2)
MM 5km 1310 1310 SM 30km 1310 1310 MM 5km 1310 1310 SM 60km 1310 1310 MM 5km 1310 1310 SM 120km 1550 1550
iConverter
MM 5 km 1310 1310
SM SF 20 km 1310 1550
MM 5 km 1310 1310
SM SF 20 km 1550 1310
MM 5 km 1310 1310
SM SF 40 km 1310 1550
MM 5 km 1310 1310
SM SF 40 km 1550 1310
SM 30 km 1310 1310
SM SF 20 km 1310 1550
SM 30 km 1310 131 0 SM 20 km 1550 131 0
SM SF 30 km 1310 1310
SM 40 km 1310 1550 SM 30 km 1310 131 0
SM SF 40 km 1550 1310
Wavelength
Port 2)
100FF Single-Fiber Modules
Tx
(nm)
Rx
Wavelength
(nm)
iConverter 1000FF Dual Fiber Modules
Connector
1
62.5/125µm, 100/140µm multimode fiber up to 220m. 50/12 5 µm multimo de fib e r up to 550 m . Re f e r to the fibe r c able manufacturer fo r multimode distance specifications.
Fiber Type
SC/SC
8642-0
8642-1
8642-2
8642-3
8643-2
8643-3
ST/SC iConverter 1000FF Sing le-Fiber Modules
8650-1
8651-1
8652-1
8653-1
8650-2
8651-2
8652-2
8653-2
Distances (Port 1 Port 2)
MM 220/550m1850 850 MM 220/550m1850 850 MM 220/550m1850 850 SM 12km 1310 1310 MM 220/550m SM 34km 1310 1310 MM 220/550m1850 850 SM 80km 1550 1550 SM 12km 1310 1310 SM 34km 1310 1310 SM 12km 1310 1310 SM 80km 1550 1550
MM 220/550m1850 850
SM SF 20 km 1310 1550
MM 220/550m
SM SF 20 km 1550 1310
SM 12 k m 1310 1310
SM SF 20 km 1310 1550
SM 12 km 1310 1310
SM SF 20 km 1550 1310
MM 220/550m1850 850
SM SF 40 km 1310 1550
MM 220/550m
SM SF 40 km 1550 1310
SM 12 k m 1310 1310
SM SF 40 km 1310 1550
SM 12 km 1310 1310
SM SF 40 km 1550 1310
(Port 1 Port 2)
Wavelen gth
1
1
1
Tx
Rx Wavelength
(nm)
850 850
850 850
850 850
(nm)
Connector
ST/ST SC/SC
8660-1 8661-1
8660-2 8661-2
8661-3
ST/SC SC/SC
8670-1 8674-1
8671-1 8675-1
8670-2 8674-2
8671-2 8675-2
8672-1 8676-1
8673-1 8677-1
8672-2 8676-2
8673-2 8677-2
iConverter
OC3FF Dual Fiber Modules
Fiber Type
Distances (Port 1 Port 2)
SM SF 20 km 1310 1550
SM SF 20 km 1550 1310
SM SF 40 km 1310 1550
SM SF 40 km 1550 1310
SM SF 20 km 1310 1550
SM SF 20 km 1550 1310
SM SF 40 km 1310 1550
SM SF 40 km 1550 1310
(Port 1
Port 2) MM 5km 1310 1310 SM 30km 1310 1310 MM 5km 1310 1310 SM 60km 1310 1310 MM 5km 1310 1310 SM 120km 1550 1550
iConverter
OC3FF Single-Fiber Modules
MM 5 km 1310 1310
MM 5 km 1310 1310
MM 5 km 1310 1310
MM 5 km 1310 1310
SM 30 km 1310 1310
SM 30 km 1310 1310
SM 30 km 1310 1310
SM 30 km 1310 1310
Tx
Wavelength
(nm)
Rx
Wavelength
(nm)
iConverter
OC12FF Dual Fiber Modules
Connector
Fiber Type
SC/SC
8681-1
8681-2
8681-3
SC/SC
8690-1
8691-1
8692-1
8693-1
1
62.5/125µm, 100/140µm multimode fiber up to 220m. 50/125µm multimode fiber up to 550m. Refer to the fiber cable manufacturer for multimode di stance specifications.
(Por t 1 Port 2)
Distances
(Por t 1 Port 2)
Tx
Wavelength
(nm)
Rx
Wavelength
(nm) MM 220/550m11310 1310 SM 12km 1310 1310 MM 220/550m1 1310 1310 SM 34km 1310 1310 MM 22 0/550m11310 1310 SM 80km 1550 1550
iConverter
OC12FF Single- Fiber Mo dules
MM 22 0/550m11310 1310
SM SF 20 km 1310 1550
1
MM 220/550m
1310 1310
SM SF 20 km 1550 1310
SM 12 km 1310 1310
SM SF 20 km 1310 1550
SM 12 km 1310 1310
SM SF 20 km 1550 1310
iConverter xFF Dual Fi ber Modules
Connector
Refer to the S F P data she e t fo r sup ported tra ns c e ivers.
Fiber Type
SFP
8699-0
Distances (Port 1 Port 2)
(Port 1 Port 2)
-
- - - -
-
Tx
Wavelength
(nm)
Rx Wavelength
- -
(nm)
LINK MODES:
In order to accommodate different user needs, the
iConverter FF media converters support two different
linking modes.
Fig. 1 Link Modes
In Link Propagate (LP) mode (sometimes referred to as Link Loss Carry Forward), a port transmits a Link signal only when receiving a Link on the other front-plane port, and a loss of a received Link at one port causes the other front-plane port to stop transmitting its link signal. For example, P1 transmits a Link only when receiving a Link at P2 [Fig 1(a)].
In Remote Fault Detection (RFD) mode, a port transmits a Link signal only when both itself and the other port are receiving Link signals. A loss of a received Link signal at a port is Looped-back and the port stops transmitting a Link signal. The same loss of Link is propagated to the other port which also stops transmitting the Link signal. For example, the loss of Link into P2 causes both P1 and P2 ports to stop transmission of the Link signal [Fig 1(b)].
Note: Connecting two adjacent converters which are both set to RFD is not permitted and will cause a “deadly embrace” lockup.
Page 7 Page 8 Page 9 Page 10 Page 11 Page 12
FRONT PANEL DIP-SWITCH SETTINGS:
Link Segment/Link Propagation “LS/LP” Dip-Switch:
This DIP-Switch has no affect. The LS function of this DIP-Switch has been disabled to enhance compatibility with third-party fiber optic devices. Fiber-to-Fiber media converters normally operate in LP mode.
Remote Fault Detection Switch “RFD” Dip-Switch:
When in the Remote Fault Detection “RFD” position, the Remote Fault Detection mode is enabled and LP mode is disabled. When in the Normal “Norm” position (factory setting), Remote Fault Detection is disabled and LP mode is enabled.
Fig. 2 Front Panel Dip-Switches
iConverter
LED INDICATORS:
LED Color Description Pwr: Yellow On--Power on
Lk/Rx (P1): Green On--Link Lk/Rx (P2): Green On--Link
MOUNTING AND CABLE ATTACHMENT:
iConverter modules are hot-swappable and can be installed
into any chassis in the
1. Carefully slide the
iConverter family.
iConverter module into installation slot,
aligning the module with the installation guides. NOTE: Ensure that the module is firmly seated against backplane.
2. Secure the module by securing panel fastener screw (attached to module) to chassis front.
3. When using an SFP model (8699-0), insert the SFP Fiber transceiver into the SFP receptacle on the module.
Note: The release latch of the SFP Fiber transceiver must be in the closed position before insertion.
4. Attach an appropriate multimode or single-mode fiber cable to each fiber connector. The transmit cable (Tx) must attach to the receive side on the other device; the receive cable (Rx) must attach to the transmit.
5. When using single-fiber (SF) models, the Tx wavelength on one end must match the Rx wavelength on the other and the converters must be used in matched pairs (example: model 8670-1 must be matched with model 8671-1).
FIBER-TO-FIBER SPECIFICATIONS:
Model Type 100FF 1000FF OC3FF OC12FF xFF
100BASE-FX,
Protocols
100BASE-BX, 100BASE-LX
Maximum Data Rate
Fiber Connectors
Controls
LED Displays
Dimensions
Weight
Compliance
Power Requirement (typical)
Temperature
Humidity
Altitude
MTBF (hrs )
155Mbps 1.25Gbps 155Mbps 1.25Gbps 1.25Gbps
SC, ST,
Single-Fiber
SC
0.5A @
3.3VDC
Standard: 0 to 50º C Wide: -40 to 60º C Storage: -40 to 80º C
1000BASE-SX, 1000BASE-LX, 1000BASE-ZX, 1000BASE-BX
Single-Fiber
Link Propagate, Remote Fault Detection
0.5A @
3.3VDC
SC,
Single-Fiber
SC
Fiber Optic Link (2)
W:0.85" x D:4.5" x H:2.8"
UL, CE, FCC Cl a ss A,
NEBS Level 3
5 to 95%
(non-condensing)
-100m to 4000m
1,300,000
OC-3 OC-12
SC, ST,
SC
Power,
8 oz.
0.5A @
3.3VDC
100BASE-FX, 1000BASE-X,
OC-3, OC-12
Fibre Channel
SC,
Single-FiberSCSFP
0.5A @
3.3VDC
0.5A @
3.3VDC
The operating description in this Instruction Manual is for
Warning
use by qualified personnel only. To avoid electrical shock, do not perform any servicing of this unit other than that contained in the operating instructions, unless you are qualified and certified to do so by Omnitron Systems T echnology , Inc.
Warranty
This product is warranted to the original purchaser against defects in material and workmanship for a period of 2 YEARS from the date of shipment. A LIFETIME limited warranty may be obtained by the original purchaser by REGISTERING this product with Omnitron within 90 days from the date of shipment. To register, complete and mail or fax the enclosed Registration Card to the indicated address. Y ou may also register your product on the internet at www.omnitron-systems.com/Register. During the warranty period, Omnitron will, at its option, repair or replace a product which is proven to be defective.
For warranty service, the product must be sent to an Omnitron designated facility, at Buyer’s expense. Omnitron will pay the shipping charge to return the product to Buyer’s designated US address (within the 48 contiguous states and the District of Columbia) using Omnitron’s standard shipping method.
The foregoing warranty shall not apply to defects resulting
Limitation of Warranty
from improper or inadequate use and/or maintenance of the equipment by Buyer, Buyer-supplied equipment, Buyer­supplied interfacing, unauthorized modifications or tampering with equipment (including repairs of equipment by personnel not specifically authorized and certified by Omnitron, or misuse, or operating outside the environmental specification of the product (including but not limited to voltage, ambient temperature, radiation, unusual dust, etc.), or improper site preparation or maintenance.
No other warranty is expressed or implied. Omnitron specifically disclaims the implied warranties of merchantability and fitness for any particular purpose.
Exclusive Remedies
The remedies provided herein are the Buyer’s sole and exclusive remedies. Omnitron shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any legal theory.
Technical Support:
For help with this product, contact our T echnical Support: Phone: (949) 250-6510 Fax: (949) 250-6514 Address: Omnitron Systems Technology, Inc.
140 Technology Dr., #500
Irvine, CA 92618 USA E-mail: support@omnitron-systems.com URL: www.omnitron-systems.com
Form: 040-08600-001L 3/08
Loading...