Omnitron Systems Technology miConverter GX, miConverter GT, miConverter GX/T User Manual

Page 2 Page 3
Page 6
Page 4
Page 5
Page 7 Page 8
the Rx wavelength must match the Tx wavelength at the other end.
4.) When using a
GX/T SFP model, insert the SFP
Fiber transceiver into the Port 1 SFP receptacle on the GX/T.
NOTE: The release latch of the SFP Fiber transceiver must be in the closed (up) position before insertion.
5.) Mount the miConverter GX/T using the included Velcro® strips or optional wall-mounting bracket kit (P/N 1091-0).
6.) To power the unit using the AC/DC adapter, connect the AC/DC adapter to the AC outlet. Then connect the barrel plug at the end of the wire on the AC/DC adapter to the 2.5mm DC barrel connector (center-positive) on the unit. Confirm that the unit has powered up properly by checking the power status LED located on the front of the unit.
To power the unit using a DC power source, prep are a power cable using a two-conductor insulated wire (not supplied) with a 14 AWG gauge minimum. Cut the power cable to the length required. Strip approximately 3/8 of an inch of insulation from the power cable wires. Connect the power cables to the
GX/T unit by fastening
the stripped ends to the DC power connector. Connect the power wires to the DC power source. The
Power LED should indicate the presence of power.
WARNING: Note the wire colors used in making the positive and negative connections. Use the same color assignment for the connection at the DC power source.
DESCRIPTION
The miConverter GX/T is a 10/100/1000BASE-T UTP to 1000BASE-X fiber media converter that supports jumbo frames up to 10,240 bytes. The
GX/T features
fixed fiber and Small Form Pluggable (SFP) transceivers that support multimode, single-mode and single-mode single-fiber options.
Both the fiber port and the UTP port support auto­negotiation, an IEEE standard which defines how all the communicating devices automatically perform their configuration functions.
The auto-negotiation feature can be disabled on both ports (for manual configuration) using DIP-switches on the product. This is useful in a situation where the
GX/T is connected to a non-negotiating device and the
configuration parameters must be set manually.
WARNING!
Before inserting the Power Adapter, verify
that the power on the adapter is appropriate
for your AC line voltage source.
POWER ADAPTER NOTICE
This product should only be used with Omnitron supplied Power Supply model numbers 9113-PS, 9115-PS, 9116-PS-3, 91 16-PS-4, 91 16-PS-5 or 91 16-PS-8.
When powering the
miConverter GX/T using the USB
Power Adapter cable (P/N 9130-2), the cable must be connected to a Full-Powered USB Type-A port (5V, 500mA).
Note: Not all USB Type-A ports are Full-Powered USB ports.
INSTALLA TION PROCEDURE
1.) Configure the appropriate miConverter GX/T DIP-Switch settings.
2.) Connect the UTP port via a Category 5 or better cable to a 10BASE-T, 100BASE-TX or 1000BASE-T Ethernet device.
3.) When using fixed fiber port models, connect the appropriate multimode or single-mode fiber cable to the fiber port of the installed module. It is important to ensure that the transmit (Tx) is attached to the receive side of the device at the other end and the receive (Rx) is attached to the transmit side. Single-fiber (SF) media converter models operate in pairs. The Tx wavelength must match the Rx wavelength at the other end and
miConverter
GX/T Media Converter
User Manual
DIP-SWITCH SETTINGS
Fig. 1 DIP-switches
Link Segment/Link Propagate “LS/LP” DIP-switch
Setting the DIP-switch to LS (Link Segment), a port transmits a Link signal independently of any received Link at any other port. For example, the UTP transmits a Link regardless of the fiber receiving a Link [Fig. 2(a) & (b)].
Setting the DIP-switch to LP (Link Propagate), a port transmits a Link signal only when receiving a Link at its other port. For example, the UTP transmits a Link only when receiving a Link at the fiber port [Fig. 2(c)].
Unit shown with optional wall-mounting bracket kit
Fig. 2 Link Modes
Link Propagate “LP” UTP Mode 1
F/O Auto-negotiate “AN”
UTP Mode 2
UTP Mode 1
F/O Manual Negotiate “Man”
UTP Mode 2
Link Segment “LS”
UP
DOWN
Fiber Type Distance
Connector Type
ST SC SFP
SFP -
- - 1239-0-x
MM 220 / 550m
1
1220-0-x 1222-0-x -
SM 12km
1221-1-x 1223-1-x -
SM 34km
- 1223-2-x -
SM 80km
- 1223-3-x -
SM 110km
- 1223-4-x -
SM 140km
- 1223-5-x -
SM-SF
1310/1550
20km
- 1230-1-x -
SM-SF
1550/1310
20km
- 1231-1-x -
SM-SF
1310/1550
40km
- 1230-2-x -
SM-SF
1550/1310
40km
- 1231-2-x -
When choosing power op tions, replace (-x) in the model number with the suffix number that corresponds to the selected power supply.
-1 US Power Supply - 120Volt / 60Hz
-2 Universal Power Supply (requires AC power cord) - 100-240Volt / 50-60Hz
-3 European Power Supply - 100-240Volt / 50-60Hz
-4 UK Power Supply - 100-240Volt / 50-60Hz
-5 Australian Power Supply - 100-240Volt / 50-60Hz
-6 USB Power Adapter Cable
-8 US/JPN Power Supply - 100-240Volt / 50-60Hz
-9 2 Pin Terminal Connector
Example: 1223-3-6 = SM / DF / 80KM with a USB P ower Adapter Cable.
For power supplies -3, -4 -5 and -8, country/region specific clips are used to provide the necessary pow er c on ne ction.
Single-Fiber converters must be used in pairs. The Tx wavelength on one end has to match the Rx wavelength on the other.
UTP Mode Configuration DIP-Switches
See the table on page 7. When configured for auto-negotiation, Pause is always
advertised. Each port will resolve Pause capability independently during auto-negotiation. If NO Pause is resolved, the port will not send or respond to Pause frames.
UTP
Mode 1
UTP
Mode 2
UTP Mode of Operation
Down Down
Confi gured for A uto Ne goti a tion.
(1000F, 1000H, 100F, 100H, 10F, 10H and Pause capable)
Down Up Manual 10M FD x
Up Down Manual 100M HDx
Up Up Manual 100M FDx
When the module is configured for auto-negotiation, the
module will advertise in the order shown in the parenthesis.
F/O Manual/Auto “Man/AN” DIP-Switch
Setting this DIP-Switch to Auto-Negotiate “AN” (factory setting) enables the fiber port to determine duplex mode automatically. If a connection can not be established, the fiber port will automatically attempt to connect to the device by reconfiguring to manual mode.
If the connected device cannot provide the proper signal to indicate its own mode of operation or the fiber port can establish a link after attempting a manual connection, this DIP-Switch should be set to Manual “Man.” This feature allows connections with legacy devices that do not support auto-negotiation.
NOTE: When the fiber port is configured for Manual Mode, a link may not occur with the connected device. Configure both devices to Manual mode to establish a link.
LED INDICATO RS
LED Function
"Legend"
Color Off State
On / Blinking S ta te
Power "Power"
Green No power
On: Module has power
Fiber Activity "F/O Link-Act"
Green No actvity
On: UTP port linked at 1000Mbps Blinking (10Hz): Link activity at
1000Mbps Blinking (1 Hz): Energy detected
F/O AN "F/O-Auto-Neg"
Green
Port configured for manual negotiation
On: Fiber port configured for AN Blinking (1 Hz): Configured as AN
but linked in Manual mode
F/O Activity + F/O AN
Green NA
Synchronized Blinking (1Hz):
AN error or Remote Fault bit detected
UTP Activity "100 Link-Act"
Green No activity
On: UTP port linked at 100Mbps Blinking (10Hz): Link activity at
100Mbps
UTP Activity "1000 Link-Act"
Green No activity
On: UTP port linked at 1000Mbps Blinking (10Hz): Link activity at
1000Mbps
UTP Activity "10 Link-Act" (100 + 1000)
Green No activity
On: UTP port linked at 10Mbps Blinking (10Hz): Link activity at
10Mbps
Page 1
Switch 1 Converter A Converter B Switch 2
LS
Fiber
UTP
UTP
UTP
UTP
Fiber
LS
Switch 1 Converter A Converter B Switch 2
LS
LS
Switch 1 Converter A Converter B Switch 2
LP
LP
LED Lit LED OffLED Lit
(A)
(B)
(C)
Page 15
Page 10 Page 11
Page 12
Page 9
Page 14
Page 16
SPECIFICATIONS
Form: 040-12200-001A 9/08
Warning
The operating description in this Instruction Manual is for use by qualified personnel only. To avoid electrical shock, do not perform any servicing of this unit other than that contained in the operating instructions, unless you are qualified and certified to do so by Omnitron Systems Technology, Inc.
Warranty
This product is warranted to the original purchaser against defects in material and workmanship for a period of TWO YEARS from the date of shipment. A LIFETIME warranty may be obtained by the original purchaser by REGISTERING this product with Omnitron within 90 days from the date of shipment. TO REGISTER, COMPLETE AND MAIL OR FAX THE ENCLOSED REGISTRATION FORM TO THE INDICATED ADDRESS. Or you may register your product on the Internet at http://www.omnitron­systems.com. During the warranty period, Omnitron will, at its option, repair or replace a product which is proven to be defective.
For warranty service, the product must be sent to an Omnitron designated facility, at Buyer’s expense. Omnitron will pay the shipping charge to return the product to Buyer’s designated US address using Omnitron’s standard shipping method.
Limitation of Warranty
The foregoing warranty shall not apply to defects resulting from improper or inadequate use and/or maintenance of the equipment by Buyer, Buyer­supplied equipment, Buyer-supplied interfacing, unauthorized modifications or tampering with equipment (including removal of equipment cover by personnel not specifically authorized and certified by Omnitron), or misuse, or operating outside the environmental specification of the product (including but not limited to voltage, ambient temperature, radiation, unusual dust, etc.), or improper site preparation or maintenance.
No other warranty is expressed or implied. Omnitron specifically disclaims the implied warranties of merchantability and fitness for any particular purpose.
Exclusive Remedies
The remedies provided herein are the Buyer’s sole and exclusive remedies. Omnitron shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any legal theory.
TECHNICAL SUPPORT :
For help with this product, contact Omnitron’s Tech. Support:
Phone: (949) 250-6510 Fax: (949) 250-6514 Address: Omnitron Systems Technology, Inc.
140 Technology #500
Irvine, CA 92618 USA E-mail: support@omnitron-systems.com URL: http://www.omnitron-systems.com
SPECIFICATIONS (CONT.)
TROUBLESHOOTING GUIDE
Problem:
The Power LED does not illuminate after installation is complete.
Possible Causes:
A. Confirm that the power supply is connected. B. Confirm that the correct power supply is being used.
Problem:
The Fiber Optic link LED does not illuminate after installation is complete.
Possible Causes:
A. Confirm that the fiber optic cable is properly connected to the
miConverter GX/T and the remote
fiber optic device. B. Confirm that the fiber cable type matches the fiber
transceiver type (multimode, single-mode) on the
miConverter GX/T
C. If using a dual-fiber model, confirm that the transmitter (Tx) is attached to the receiver side of its link partner, and that the receiver (Rx) is attached to the transmitter.
D. If using a single-fiber model, confirm that the Tx wavelength on the
miConverter GX/T matches the Rx
of the connected fiber optic device.
Problem:
The UTP link LED does not illuminate after installation is complete.
Possible Causes:
A. Confirm that the UTP cable is connected properly to the
miConverter GX/T and the attached UTP device.
B. Confirm that the UTP cable pin-out is correct (EIA/ TIA-568-A).
C. Verify the
miConverter GX/T UTP port is configured
with the proper settings based on the attached device (AN or MAN, 1000,100 or 10, HD or FD).
Note: If corrective actions do not resolve your situation, please contact Omnitron Systems Technical Support.
Page 13
Model miConverter GX/T Description 10/100/1000BASE-T UTP to 1000BASE-X
Fiber Converter
Protocols
10BASE-T, 100BASE-TX, 1000BASE-T,
1000BASE-X
Frame Size
10,240 byte max frame size
Cable Types
UTP
EIA/TIA 568A/B, Category 5 and higher
Fiber
Multimode: 50/125, 62.5/125, 100/140 um,
Single-mode: 9/125 um
Connector Types
UTP
RJ45
Fiber Dual Fiber Single-Fiber SFP
SC, ST
SC LC
LED Display Pwr, AN, F/O Lk,
UTP-10, UTP-100, UTP-1000
Power Requirements
DC Power (Typical)
5 to 12VDC
0.35A @ 5VDC
DC Power Connector 2.5mm DC Jack
or
2 Pin Terminal Connector
AC Power Adapter [US]
100-120VAC/60Hz
0.02A @ 120VAC
AC Power Adapter [Universal or Country/Region Specific]
100-240VAC/50-60Hz
0.02A @ 120VAC
Dimension
W:1.71" x L:4.10" x H:0.84"
Weight
without power adapter
5 oz.
with USB power adapter
6 oz.
with AC power adapter [US]
12 oz.
Compliance Operational Temperature
Standard
0 to +50
o
C
Storage Temperature
-50 to +80
o
C
Humidity (non-condensing)
5 to 95%
Altitude
-100m to 4000m
MTBF [hrs]
without power adapter
878,000
with US or Country/Region Specific power adapter
250,000
with Universal power adapter
100,000
Loading...