AN Auto (default)
MAN 10Mbps HD
MAN 100Mbps FD
LS (default)
LP
MAN 100Mbps HD
UTP ModeLink Mode
miConverter
Switch 1 Converter A Converter B Switch 2
LP
RFD+LS
(D)
RFD
Switch 1 Converter A Converter B Switch 2
SFD
SFD
(E)
RFD
LED ON LED OFFLED
LED Flashing
LED ON or OFF
™
10/100 Plus
Media Converter
User Manual
Fiber Mode Type /
Dual Fiber [DF] or
Single-Fiber [SF]
When choosing power options, replace (-x) in the model number
with the suffix number that corresponds to the power supply of
choice below. Example: 1103-3-6 stands for
1103-3-x with USB Power Adapter
-1 US Power Supply - 120Volt / 60Hz
-2 Universal Power Supply (requires AC power cord) 100-240Volt / 50-60Hz
-3 Euro Power Supply - 100-240Volt / 50-60Hz
-4 UK Power Supply - 100-240Volt / 50-60Hz
-5 Australia Po wer S upply - 100-240Volt / 50-60Hz
-6 USB Power Adapter Cable
-8 US/JPN Power Supply - 100-240Volt / 50-60Hz
For power supplies -3, -4, -5 and -8, country/region specific clips are
used to provide the necessary power connection.
miConverter
MM / DF 5km 1120-0-x 1122-0-x 1310 1310
SM / DF 30km 1121-1-x 1123-1-x 1310 1310
SM / DF 60km 1121-2-x 1123-2-x 1310 1310
SM / DF 120km - 1123-3-x 1550 1550
SM / SF 20km - 1130-1-x 1310 1550
SM / SF 40km - 1130-2-x 1310 1550
SM / SF 20km - 1131-1-x 1550 1310
SM / SF 40km - 1131-2-x 1550 1310
Distance
10/100 Plus Models
Connector Types
ST SC
Page 1
Tx
Lambda
[nm]
Rx
Lambd
[nm]
Accessories
Wall Mounting Hardware Kit 4381
USB Power Adapter Cable 9130-2
US Domestic AC Power Adapter 9113-PS
Universal AC Power Adapter
(requires AC power cord)
Europe AC Power Adapter 9116-PS-3
United Kingdom AC Power Adapter 9116-PS-4
Australia AC Power Adapter 9116-PS-5
Japanese AC Power Adapter 9116-PS-8
European Connector Clip* 9116-3
UK Connector Clip* 9116-4
Australian Connector Clip* 9116-5
Japanese Connector Clip* 9116-8
*All spare Connector Clips are interchangeable with AC Power
Adapters 9116-PS-3, 9116-PS-4, 9116-PS-5 and 9116-PS-8
9115-PS
DESCRIPTION
The
miConverter™ 10/100 Plus is a 10/100BASE-T copper
to 100BASE-FX fiber media converter. The UTP copper
port can automatically detect the speed, duplex mode
and crossover mode of the connected device, or it can
be manually configured via DIP-switches.
The 100BASE-FX fiber port operates in Full-Duplex
mode and supports single-mode or multimode fiber
with ST or SC fiber connectors. Single-mode models
feature Bi-Directional fiber and support distances of
up to 40km. The various fiber models options are
described in the table on the first page.
Several Link Modes (fault-detection capabilities) are
Page 2 Page 3
available with the 10/100 Plus, including Link Segment
(Normal Mode), Link Propagate (Link Loss Carry
Forward), Remote Fault Detection and Symmetrical
Fault Detection. The link mode assist in the
identification and isolation of link failures.
WARNING!
Before inserting the Power Adapter, verify
that the power on the unit is appropriate
for your AC line voltage source.
POWER ADAPTER NOTICE
This product should only be used with Omnitron supplied
Power Supply model numbers 9113-PS, 9115-PS,
9130-2, 9116-PS-3, 9116-PS-4, 9116-PS-5 or
9116-PS-8.
In order to guarantee performance when powering the
miConverter 10/100 Plus with the USB Power
Adapter cable (P/N 9130-2), the cable must be
connected to a Full-Powered USB Type-A port (5V,
500mA).
NOTE: Not all USB Type-A ports are Full-Powered
USB ports. The Full-Powered USB Type-A ports
are usually the USB ports found on computer
cases or on self-powered (powered by an AC
adapter) USB hubs.
INSTALLA TION PROCEDURE
1. Configure the miConverter 10/100 Plus with the
appropriate DIP-switch settings. The factory default
configuration for the UTP copper port is “AN” Auto-
negotiation and the Link Mode is “LS” Link Segment.
2. Connect the UTP port to a 10BASE-T or 100BASE-TX
Ethernet device using a Category 5 cable (or better).
3. Connect the fiber optic port to a 100BASE-FX Fast
Ethernet device via the fiber cable of the appropriate
mode and type. When connecting dual fiber models,
miConverter 10/100 Plus transmitter (Tx) must
the
attach to the receiver side of its link partner; the
receiver (Rx) must attach to the transmitter. When
connecting single-fiber (SF) models, the Tx
wavelength on one end has to match the Rx wavelength
on the other. Based on this guideline, the SF media
converter models must be used in pairs, such as the
1130-2-x matched with the 1131-2-x.
4. Mount the
included Velcro
miConverter 10/100 Plus using the
®
strips or optional wall-mounting
bracket kit (P/N 1091-0).
5. Connect the appropriate power source.
DIP-SWITCH SETTINGS
Figure 1: DIP-switch Configurations
Page 4
UTP Mode Selection
The UTP port is configured using the DIP-switches
as shown in Figure 1. There are four modes of
operation based on the position of the DIP-switches.
The factory default configuration is “AN” Autonegotiation. In the “AN” mode, the port will advertise
100Mbps Full-Duplex, 100Mbps Half-Duplex, 10Mbps
Full-Duplex and 10Mbps Half-Duplex.
The UTP port can be configured for Manual negotiation
by setting the appropriate DIP-switches. The port
can be configured for 100Mbps Full-Duplex, 100Mbps
Half-Duplex and 10Mbps Half-Duplex.
Link Mode Selection
miConverter 10/100 Plus can be configured for
The
several different Link Modes. The DIP-switch
illustration in Figure 1 indicates how to configure the
different Link Modes.
Link Segment (LS)
“LS” (factory default) generates and detects a link
signal at each point in the network. Utilizing this
configuration, a loss of a receive link signal will only
affect the port detecting the loss of signal. All the
other ports will continue to generate a link signal.
Figure 2(A) indicates the normal operation of the
system without faults. Figure 2(B) indicates a loss
of a receive link on the fiber optic port, the UTP
port continues to maintain its link.
Page 5
Link Propagate (LP)
“LP” generates (transmits) a link signal only when a
link signal is detected. Utilizing this configuration, a
loss of a receive link signal will continue to ‘propagate’
through to the next port in the network. In Figure
2(C), a loss of a receive link on the fiber optic port
causes the UTP port to drop its link due to the
propagated fiber optic link state. This setting allows
the loss of a link to be detected by SNMP or other
managed network devices to which the miConverter
10/100 Plus is connected.
NOTE: Only the first loss of a receive link detected by
miConverter 10/1 00 Plus turns off the other port’s
the
transmit link. An additional loss of a receive link on the
other port has no affect on the miConverter 10/100
Plus. The miConverter 10/100 Plus returns to normal
operation when the first loss of a receive link is restored.
Symmetrical Fault Detect (SFD)
“SFD” generates a Link Loss signal on all ports on
both media converters when a loss of link signal is
detected by one of the ports. In Figure 2(E), the
pattern of LEDs gives an indication of the failure
point.
NOTE: Both media converters must be configured
with the SFD Link Mode. The SFD function is only
supported by Omnitron Systems equipment.
Normal Operation
(A)
UTP
UTP
Fiber
Fiber
UTP
UTP
Switch 1 Converter A Converter B Switch 2
LS
LS
Remote Fault Detect + Link Segment (RFD + LS)
“RFD+LS” generates a link signal only when a link
signal is detected. However, instead of propagating
the fault forward, the loss of link is looped back. In
Figure 2(D), a loss of a received link state is looped
back causing the port to stop transmitted the link
state. Because the other unit is configured for Link
Propagate, the UTP port will drop its link due to the
propagated fiber optic link state.
(B)
Switch 1 Converter A Converter B Switch 2
LP
LP
(C)
- LED status depends on the link
type; AN - OFF, MAN - ON
Figure 2: Link Modes
NOTE: It is not permitted to set both Converter A and
B to RFD at the same time; a deadly embrace will
Switch 1 Converter A Converter B Switch 2
occur.
Page 6
Page 7 Page 8
LED INDICAT ORS:
Function Legend Color Off On
Power Pwr Amber No power Power applied
F/O Link-
Act
UTP Link Act
0(Off) /
00(On)
HDX(O ff) /
FDX(On)
NOTE: For additional assistance with the LED
indicators, please refer to the miConverter 10/100
Plus TROUBLESHOOTING GUIDE (pp 12 -13).
F/O Green No link Solid = Link
Rapid Blinking (10Hz)
= Data
Slow Blinking (5Hz)
UTP Green No link Solid = Link
100 Green UTP = 10Mbps
FDX Green Half-Duplex
when UTP Link
is active
when UTP Link
is active
= SFD E rro r D e t.
Rapid Blinking (10Hz)
= Data
Slow Blinking (5Hz)
= SFD E rro r D e t.
UTP = 100Mbps when
UTP Link is active
Full-Duplex when UTP
Link is active
Page 9
SPECIFICATIONS:
miConverter
escription Miniature 10/100BASE-T Copper
rotocols 10BASE-T, 100BASE-TX,
able Types
UTP EIA /TIA 568A/B,
Fiber Multimode: 50/125, 62.5/125,
onnector Types
UTP RJ45
Fiber Dual fiber: SC, ST
ED Displa ys Pwr, FO-Lk/Ac t, UTP-Lk /A c t,
ower Requirements
DC Power 0.5A @ 5VDC
DC Power Connector 2.5mm DC Jack - Center Positive
AC Power Adapter
[US]
AC Power Adapter
[Universal or
Country/Region Specific]
10/100 Plus Specifications
to 100BASE-FX Fiber
Media Converter
100BASE-FX
with 1536 bytes max. frame size,
IEEE 802.3 specification
Category 5 and higher
100/140 um
Single-mode: 9/125 um
Single-fiber: SC
UTP-10/100, HDX/FDX
100-120VAC/60Hz
0.03A @ 120VAC
100-240VAC/50-60Hz
0.03A @ 120VAC
Page 10 Page 11
SPECIFICATIONS (CONT. ):
imensions W:1.71" x L:4.10" x H:0.84"
Weight
without power adapter 4 oz.
with USB power adapter cable 5 oz.
with AC power adapter [US] 12 oz.
with AC power adapter
[Universal]
ompliance UL, CE, FCC Class A
Temperature
Operational - Commercial 0 to +50
Storage -50 to +80
umidity
non-condensing)
Altitude -100m to 4000m
TBF [hrs]
without power adapter 1,000,000
with US or
Country/Region Specific
power adapter
with Universal power adapter 100,000
18 oz.
5% to 95%
250,000
o
C
o
C
TROUBLESHOOTING GUIDE:
Problem:
The Power LED does not illuminate after installation
is complete.
Possible Causes:
A. Confirm that the power supply is connected.
B. Confirm that the correct power supply is being
used.
Problem:
The Fiber Optic link LED does not illuminate after
installation is complete.
Possible Causes:
A. Confirm that the fiber optic cable is properly
connected to the miConverter 10/100 Plus and the
remote fiber optic device.
B. Confirm that the fiber cable type matches the
fiber transceiver type (multimode, single-mode) on
the
miConverter 10/100 Plus.
C. If using a dual-fiber model, confirm that the
transmitter (Tx) is attached to the receiver side of its
link partner, and that the receiver (Rx) is attached to
the transmitter.
D. If using a single-fiber model, confirm that the Tx
wavelength on the miConverter 10/100 Plus matches
the Rx of the connected fiber optic device.
E. Verify the Link Mode selection is set to Link
Segment (LS). Until a stable link is established, leave
the Link Mode configured for LS. After a Link presence
Page 12
is established, the Link Mode selection can be
modified.
Problem:
The UTP link LED does not illuminate after installation
is complete.
Possible Causes:
A. Confirm that the UTP cable is connected properly
miConverter 10/100 Plus and the attached
to the
UTP device.
B. Confirm that the UTP cable pin-out is correct (EIA/
TIA-568-A).
C. Verify the
configured with the proper settings based on the
attached device (AN or MAN, 10 or 100, HD or FD).
miConverter 10/100 Plus UTP port is
NOTE: If corrective actions do not resolve your
situation, please contact Omnitron Systems
T echnical Support.
Page 13
Warning
The operating description in this Instruction Manual is
for use by qualified personnel only. To avoid electrical
shock, do not perform any servicing of this unit other
than that contained in the operating instructions, unless
you are qualified and certified to do so by Omnitron
Systems Technology, Inc.
Warranty
This product is warranted to the original purchaser
against defects in material and workmanship for a
period of TWO YEARS from the date of shipment. A
LIFETIME warranty may be obtained by the original
purchaser by REGISTERING this product with
Omnitron within 90 days from the date of shipment.
TO REGISTER, COMPLETE AND MAIL OR FAX THE
ENCLOSED REGISTRATION FORM TO THE
INDICATED ADDRESS. Or you may register your
product on the Internet at http://www.omnitronsystems.com. During the warranty period, Omnitron
will, at its option, repair or replace a product which is
proven to be defective.
For warranty service, the product must be sent to an
Omnitron designated facility, at Buyer’s expense.
Omnitron will pay the shipping charge to return the
product to Buyer’s designated US address using
Omnitron’s standard shipping method.
Page 14
Limitation of Warranty
The foregoing warranty shall not apply to defects
resulting from improper or inadequate use and/or
maintenance of the equipment by Buyer, Buyersupplied equipment, Buyer-supplied interfacing,
unauthorized modifications or tampering with
equipment (including removal of equipment cover by
personnel not specifically authorized and certified by
Omnitron), or misuse, or operating outside the
environmental specification of the product (including
but not limited to voltage, ambient temperature,
radiation, unusual dust, etc.), or improper site
preparation or maintenance.
No other warranty is expressed or implied. Omnitron
specifically disclaims the implied warranties of
merchantability and fitness for any particular purpose.
Exclusive Remedies
The remedies provided herein are the Buyer’s sole
and exclusive remedies. Omnitron shall not be liable
for any direct, indirect, special, incidental, or
consequential damages, whether based on contract,
tort, or any legal theory.
Page 15
TECHNICAL SUPPORT :
For help with this product, contact Omnitron’s Tech.
Support:
Phone: (949) 250-6510
Fax: (949) 250-6514
Address: Omnitron Systems Technology, Inc.
140 Technology #500
Irvine, CA 92618 USA
E-mail: support@omnitron-systems.com
URL: http://www.omnitron-systems.com
Form: 040-11200 -001 B 11/07
Page 16