Omnitron Systems Technology iConverter RS232 User Manual

iConverter
®
RS232
Serial RS-232 to Fiber Media Converter
User Manual
Port 1 (P1)
Port 2 (P2)
iConverter
RS232 Models
Fiber Type /
Dual Fiber (DF) /
Wave length ( nm )
MM/DF/1310 5km 8760-0 8762-0 ­SM/DF/1310 30km 8761-1 8763-1 8767-1 SM/DF/1310 60km 8761-2 8763-2 8767-2 SM/DF/1550 120km - 8763-3 8767-3
When ordering module with terminal block serial port, append 'T'
before the dash '-' in the part number.
Examples: 8760T-0, 8763T-3, 8770T-1
Distance
Fiber Connector Types
ST SC LC
Page 1 Page 2 Page 3 Page 4 Page 5
iConverter
RS232 Single-Fiber Models
Fiber Type /
or Si ngle -Fiber (S F) /
Wavelength (nm)
SM/SF
Tx1310 / Rx1550
SM/SF
Tx 1550 / Rx 1310
SM/SF
Tx1310 / Rx1550
SM/SF
Tx 1550 / Rx 1310
For wide temperature (-40 to 60ºC), add a "W" to the end of the model number. Consult factory for extended temperature (-40 to +75ºC) models. When using single-fiber (SF) media converter models, the Tx wavelength on one end has to match the Rx wavelength on the other. When ordering module with terminal block serial port, append 'T' before the dash '-' in the part number. Examples: 8760T-0, 8763T-3
Distance
20km 8770-1
20km 8771-1
40km 8770-2
40km 8771-2
Fiber Type
SC
OVERVIEW:
The Omnitron iConverter RS232 is a manageable serial RS-232 to fiber converter that transmits serial signals over fiber media. Fiber transmission can extend serial signals up to 120km and is immune from electrical and magnetic interference. The RS232 is available with a single-mode, multimode or single-fiber transceiver. The serial port is available with a DB-9 female connector or terminal block connector.
The RS232 automatically detects the signal baud rate of the connected serial device, ranging from 110 to 921,600 baud. The RS232 automatically adjusts to changes in the connected device’s baud rate during operation, without reconfiguration or interruption.
Connection to DTE or DCE devices is configured by an easily accessible DIP-Switch on the front-panel. A built­in remote Fiber Loop-Back DIP-Switch provides easy validation of the entire fiber segment from either terminal RS232 converter, without having to enable this function on both converters.
The RS232 is designed to work in any When installed in a multi-module chassis, the RS232 can
iConverter chassis.
be remotely monitored and managed by software control.
iConverter 19-Module, 5-Module and 2-Module chassis
The all support the software control feature. The 1-Module chassis supports RS232 as a standalone serial to fiber converter.
Note that software control for remote configuration of the RS232 requires a multi-module chassis with
iConverter Management Module, such as the
an Network Management Module (NMM).
For more information on using and configuring RS232 via software control, please refer to the
NetOutlook
Management Software user manual.
PORT STRUCTURE:
Front-Panel Ports:
The front-panel of the fiber port (P1) and one RS-232 serial port (P2). Depending on the model, the serial port is available either as a DB-9 female connector or as a terminal block for field wiring. Please refer to Fig. 1a and Fig. 1b for connector pin-out assignment.
iConverter RS232 features one
Fig. 1a DB-9 Connector Pin-Out Assignment
Fig. 1b Terminal Block Pin-Out Assignment
PIN No. PIN Signal Abbr. DTE DCE
1 Data Carrier Detect DCD IN OUT 2 Received Data RD IN OUT 3 Transmitted Data TD OUT IN 4 Data Terminal Ready DTR OUT IN 5Signal GroundSGND-­6 Data Set Ready DSR IN OUT 7 Request to Send RTS OUT IN 8Clear to SendCTSINOUT 9Ring IndicatorRIINOUT
DIP-SWITCH SETTINGS:
Fig. 2 Front-Panel DIP-Switches
SW1: Normal and Fiber Loop-Back “Norm / FLB” DIP-Switch:
When the Normal and Fiber Loop-Back “Norm / FLB” DIP-Switch is in the normal mode “Norm” position (factory default), the Fiber Loop-Back is disabled. Setting this DIP-Switch to the “FLB” position on the RS232 at either end of the fiber segment will enable the Fiber Loop-Back test. When Fiber Loop-back is enabled, the local RS232 with the DIP-Switch in “FLB” position is the master, and the remote RS232 with the DIP-Switch in “Norm” position is the slave. The “Tst” LED on the master will blink rapidly (10 times per second) and the “T st” LED on the slave will blink slowly (once per second) if the fiber segment passes the Loop-back test. If the fiber segment fails the Loop­back test, the “Tst” LED on master unit will remain solid.
Note that the Fiber Loop-back test does not interfere with serial conversion and signal transmission.
Note that only one RS232 on either end of the fiber segment needs to be set to “FLB” position during the Loop-back test.
SW2: Serial “DCE / DTE” DIP-Switch:
When the “DCE / DTE” DIP-Switch is in the “DCE” position (factory default), the RS232 is configured to connect to Data Communications Equipment such as a modem or
printer. Setting this DIP-Switch to the “DTE” position configures the RS232 to connect to Data Terminal Equipment such as a computer or controller. Please refer to the PORT STRUCTURE section of this manual for more details.
MOUNTING AND CABLE ATTACHMENT:
iConverter modules are hot-swappable and can be installed
into any chassis in the
iConverter family.
1. After configuring the DIP-Switches, carefully slide
iConverter module into the installation slot, aligning
the the module with the installation guides. Ensure that the module is firmly seated against the Backplane.
2. Secure the module by fastening the panel thumb screw (attached to the module) to chassis front.
3. Attach the serial ports via a DB-9 serial cable (or an open-end serial cable) to a serial RS-232 device.
4. Attach the fiber port via an appropriate multimode or single-mode fiber cable to a 100BASE-FX Fast Ethernet device. The
iConverter transmit (Tx) must attach to
the receive side on the other device; the receive (Rx) must attach to the transmit side.
5. When using single-fiber (SF) media converter models, the Tx wavelength on one end has to match the Rx wavelength on the other. Note that based on this guideline the SF media converter models must be used in pairs, such as the 8770-1 matched with the 8771-1.
Page 6 Page 7
RS232 LED INDICATORS: RS232 SPECIFICATIONS:
LED Function
"Legend"
Power "Pwr" Ambe r No Po wer Module has p ower
Fiber Loop­back Test "Tst"
Fiber Link and Activities "Act"
"DTE" Mode Green
"DCE" Mode Green Serial Activities
"Act"
Co lor Off State On / B l inking State
Master mode Tx
Solid: pattern sent, but no Rx received 10 Hz (Blinking 10x per
Green
Green
Green
Normal Mode
No Fiber Link
DTE mode not selec t ed
DCE mode not selec t ed
No ser ial data
second): Maste r mode, Tx pattern sent, and Rx pattern received 1 Hz (Blinking once per second): Slave mode, Rx pattern received
Fiber Link
Solid: Blinking::
Fiber Data
Transmission DTE mode selected
DCE mode selected
Serial data received
Model Type RS232 Protocols
Asynchronous Seri al RS-232
Copper Connectors
Fiber Connectors
Controls
LED Displays Dimensions
DTE/DCE, Fiber Loop-Back
Power, Test, Fiber Lnk/Act,
DTE, DCE, Serial Act
W:0.85" x D:4.5" x H:2.8"
Weight Compliance
Power Requirement
UL, CE, FCC Class A
0.5A @ 3.3VDC (typical)
Standard: 0 to 50º C
Temperature
Wide: -40 to 60º C Storage: -40 to 80º C
Humidity
5 to 95% (non-condensing)
Altitude MTBF ( h rs )
Page 8
DB-9 Female or
Terminal Block
ST, SC, LC
8 oz.
-100m to 4000m 850,000
Warning
The operating description in this Instruction Manual is for use by qualified personnel only. T o avoid electrical shock, do not perform any servicing of this unit other than that contained in the operating instructions, unless you are qualified and certified to do so by Omnitron Systems Technology, Inc.
Warranty
This product is warranted to the original purchaser against defects in material and workmanship for a period of TWO YEARS from the date of shipment. A LIFETIME warranty may be obtained by the original purchaser by REGISTERING this product with Omnitron within 90 days from the date of shipment. TO REGISTER, COMPLETE AND MAIL OR FAX THE ENCLOSED REGISTRATION FORM TO THE INDICATED ADDRESS. Or you may register your product on the Internet at www.omnitron­systems.com. During the warranty period, Omnitron will, at its option, repair or replace a product which is proven to be defective.
For warranty service, the product must be sent to an Omnitron designated facility, at Buyer’s expense. Omnitron will pay the shipping charge to return the product to Buyer’s designated US address using Omnitron’s standard shipping method.
Limitation of Warranty
The foregoing warranty shall not apply to defects resulting from improper or inadequate use and/or maintenance of the equipment by Buyer, Buyer-supplied equipment, Buyer-supplied interfacing, unauthorized modifications
Page 9 Page 10
or tampering with equipment (including removal of equipment cover by personnel not specifically authorized and certified by Omnitron), or misuse, or operating outside the environmental specification of the product (including but not limited to voltage, ambient temperature, radiation, unusual dust, etc.), or improper site preparation or maintenance.
No other warranty is expressed or implied. Omnitron specifically disclaims the implied warranties of merchantability and fitness for any particular purpose.
Exclusive Remedies
The remedies provided herein are the Buyer’s sole and exclusive remedies. Omnitron shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any legal theory.
TECHNICAL SUPPORT :
For help with this product, contact our T echnical Support: Phone: (949) 250-6510 Fax: (949) 250-6514 Address: Omnitron Systems Technology, Inc.
140 Technology Dr.
Irvine, CA 92618 USA E-mail: support@omnitron-systems.com URL: www.omnitron-systems.com
Form: 040-08760-001D 12/12