Omnitron Systems Technology iConverter 2FXM2 User Manual

Management Options iConverter, Serial Agent Network Management 1: Chassis and Module Management 2: Set Module Name Preferences Management Module Preferences 3: IP and Control Preferences 4: SNMP Preferences 5: Abandon Preference Changes 6: Save Preference Changes 7: Restore Factory Defaults 8: Restart Management Module 9: Other Networking Features Management Module Maintenance 10: Firmware Update 11: Set Date/Time
IP Address = 192.168.1.220 Chassis Number = 1
Enter Choice, <H>elp, E<x>it >
Figure D: Command Line Interface Menu Options
The CLI interface allows for the detailed configuration of the module. It is recommended to configure the module with an IP address associated with the attached network. Also, SNMP traphost address should be configured if the module is managed with an SNMP-based Management System. See the 2FXM2 User Manual for complete information.
4) VERIFY OPERA TION
Once the module has been installed and configured per steps 1 - 3, verify the module is operational by viewing the LED indicators.
The Power LED indicates the module is receiving power from the chassis.
The Fiber Optic link LEDs indicate the fiber optic connections have been established. Verify the Link Mode selection is set to Link Segment (LS). Until a stable link is established, leave the Link Mode configured for LS. After a Link presence is established, the Link Mode selection can be modified.
Omnitron Systems Technology * 140 Technology Dr. * #500 * Irvine, CA 92618
949.250.6510 tel * 949.250.6514 fax * www.omnitron-systems.com
LED Function
"Legend"
Power "Pwr" Green No power On: Module has power
Power Supply Status #X
Port 1 Fiber Link Acti vity "P1" Port 1 Half/Full Duplex "FDX" Chass is Management Master/Slave "Msr/Slv" Port 2 Fiber Link Acti vity "P2" Port 2 Half/Full Duplex "FDX"
Co lor Off S tate On / Blinki ng St a te
Chassis Power
Green
Supply not i nsta lle d
Green No Fiber Link
Green Half-Duplex On: Full-Duplex
Chassis Slave
Green
Mode
Green No Fiber Link
Green Half-Duplex On: Full-Duplex
On: Power available from installed Power Supply #X Blinking: No power available from installed Power Supply #X
On: Fiber link is active Blinki ng: Fiber Data Activity
On: Chassis Master Blinking: Operating in OAM Mode
On: Fiber link is active Blinki ng: Fiber Data Activity
Figure E: LED Indicators
Form 040-8940N-002 B
iConverter 2FXM2 Plug-in Module QUICK START GUIDE
The Omnitron iConverter (NID) with integrated management provides Fast Ethernet (100BASE-FX) fiber-to-fiber media conversion.
The 2FXM2 conforms to Ethernet in the First Mile (EFM) fiber standards to support Fiber-to-the-X (FTTX) Metropolitan and Enterprise LAN networks. Built-in Operation, Administration and Maintenance (OAM) functionality enables the 2FXM2 to operate as a managed demarcation point at the customer premises and network edge, offering service provisioning functions, such as Quality of Service and Bandwidth Control (rate-limiting) capabilities.
The 2FXM2 module can be managed using Omnitron’s
NetOutlook
TM
SNMP Management Software, 3rd Party SNMP-Client, Telnet or the
Command Line Interface (CLI). For more information, including the complete User Manual on the 2FXM2 Plug-in
module, access Omnitron’s documentation download web page to view all relevant documents:
http://www.omnitron-systems.com/downloads.php
INSTALLATION PROCEDURE
1) Configure DIP-Switches
2) Install Module in Chassis and Connect Cables
3) Configure Module via Command Line Interface
4) Verify Operation
1) CONFIGURE DIP-SWITCHES DIP-SWITCH BANK 1
SW1 - PAUSE ENABLE
When the Pause Enable DIP-switch is in the LEFT “Off” position (factory default), the 2FXM2 disables the fiber ports’ ability to send and receive Pause frames during network congestion. Setting this DIP-switch to the RIGHT “On” position, enables the 2FXM2 to receive Pause frames from its link partner . This enables the 2FXM2 to stop transmitting traffic to its link partner and store incoming frames from the other port in the internal buffer until the congestion clears. If the internal buffer of the 2FXM2 becomes congested, it will transmit a Pause frame to its link partner.
SW2 - FIBER PORT 1 FULL/HALF DUPLEX
Setting this DIP-switch to Half-Duplex “HDX” facilitates a connection that supports Half-Duplex. Setting this DIP-switch to Full-Duplex “FDX” facilitates a connection that
®
2FXM2 Network Interface Device
Switch 1
Switch 8
Switch 1
Switch 8
LEFT
Figure A: DIP-Switch Locations
Bank 2
Bank 1
RIGHT
supports Full-Duplex operation.
SW3, SW4 - RESERVED
These DIP-switches are for factory use only and must always remain in the LEFT (factory default) position.
SW5 - FIBER PORT 2 FULL/HALF DUPLEX
Setting this DIP-switch to Half-Duplex “HDX” facilitates a connection that supports Half-Duplex. Setting this DIP-switch to Full-Duplex “FDX” facilitates a connection that supports Full-Duplex operation.
SW6, SW7, SW8 - LINK MODES
The module supports multiple link modes for fault detection and isolation. Link Segment should be used for the initial installation of the module. Once installed and operational, the link mode can be changed. For detailed information on the operation of the different Link Modes, download the application note “iConverter Link Modes” available on Omnitron’s web page: http://www.omnitron-systems.com/downloads.php
Switch Left
(Factory Default)
SW1 Off:
Pause Disable
SW2 FDX:
Fiber Port 1Full-Duplex
SW3
Reserved Reserved
SW4
Reserved Reserved
SW5 FDX:
Fiber P o rt 2 Full-Duplex
SW6
SW7 Left Right Right Asymmetrical Link Propagate
SW8 Right Right Right Asymmetrical RFD+ LP
See Link Mode Selection
Right SW6 SW7 SW8 Link Mode Selection
PAUS:
Pause Enable
HDX:
Fiber Port 1Half-Duplex
HDX:
Fiber Port 2Half-Duplex
Left Left Left Link Segment (LS)
Right Left Left Link Propagate (LP)
Left Right Left Remote Fault Detect + Link
Right Right Left Remote Fault Detect + Link
Left Le ft Righ t Sy m me trical Fau lt D etect (S F D)
Right Left Right Asymmetrical Link Propagate
(Fac to ry D e fa ult)
Segment (RF D + LS )
Propagate (RFD + LP)
P1 to P2 (ALP P1-P2)
P2 to P1 (ALP P2-P1)
P1 to P2
Figure B: DIP-Switch Bank 1
DIP-SWITCH BANK 2
SW1, SW2 - BACKPLANE ENABLE
When the DIP-switch is in the LEFT “DS” position (factory default), the Backplane Port of the 2FXM2 is isolated from the chassis’ Ethernet Backplane. When the DIP-switch is in the RIGHT “EN” position, the Backplane Port is enabled. This allows Ethernet Backplane connectivity to an adjacent module via the chassis Backplane Link “A” or “B” depending on the switch setting.
Switch Left
(Factory Default)
SW1 A-DS:
Port A Disabled
SW2 B-DS:
Port B Disabled
SW3 Reserved Reserved SW4 M/SL:
Auto Select
SW5 - SW8 Reserved Reserved
Right
A-EN:
Port A Enabled
B-EN:
Port B Enabled
SL:
Slave-Mode Only
Figure C: DIP-Switch Bank 2
SW4 - MASTER/SLAVE
When the 2FXM2 module is installed in a chassis with an
iConverter Network
Management Module (NMM), set DIP-switch to the LEFT “M/SL” position (factory default). The assignment of mastership is automatically negotiated by the installed management modules. To designate the 2FXM2 module as the master of the chassis, set the DIP-switch to the LEFT “M/SL” position, and set the other installed management modules’ DIP-switches to the RIGHT “SL” position to enable Slave­Only mode.
SW5, SW6, SW7, SW8 - RESERVED
These DIP-switches are for factory use only and must always remain in the LEFT (factory default) position.
2) INST ALL MODULE IN CHASSIS AND CONNECT CABLES
a. Carefully slide the module into an open slot in the chassis. Align the module with the
installation guides and ensure that the module is firmly seated against the backplane. Secure the module by fastening the front panel thumbscrew (push in and turn clockwise to tighten) to the chassis front. V erify the “Pwr” LED is ON (indicating the chassis is powered).
b. Insert the SFP Fiber transceivers into the Port 1 and Port 2 SFP receptacles on the
2FXM2.
NOTE: The release latch of the SFP Fiber transceiver must be in the closed position before insertion.
d. Connect an appropriate multimode or single-mode fiber cable to the SFP fiber ports
of the installed module. It is important to ensure that the transmit (TX) is attached to the receive side of the device at the other end and the receive (RX) is attached to the transmit side. Single-fiber (SF) media converter models operate in pairs. The TX wavelength must match the RX wavelength at the other end and the RX wavelength must match the TX wavelength at the other end.
NOTE: In order to support Remote OAM Management Mode, Port 1 of the 2FXM2 must be connected to the Port 1 on the 2FXM2 or link partner.
3) CONFIGURE MODULE VIA COMMAND LINE INTERF ACE
To access the Command Line Interface (CLI), connect the 2FXM2 RS-232 Console Port to the COM port of a computer equipped with terminal emulation software such as HyperTerminal. The Console Port (DCE) is a mini DIN-6 female connector which can be changed to a DB-9 connector with the included adapter. The 2FXM2 Console Port is a standard asynchronous serial interface.
Start HyperTerminal and select the correct COM Port in the HyperTerminal “Connect To:” window. Set the serial port to the following:
Bits Per Second 57,600 Stop Bits 1 Data Bits 8 Parity NONE Hardware Flow Control NONE
Once connected, press <ENTER> to bring up a command line prompt on the attached PC. A new 2FXM2 module does not have a password, and will skip the Password Entry screen and go straight to the Management Options screen. If a password has been set, the Password Entry screen will be displayed. Type the p assword and press <ENTER>, the 2FXM2 will respond with the Management Options screen: