iConverter
iConvert er 1000FF Dual Fi ber Modules
Connector
SC/SC
Fiber Type
(Port 1
Port 2)
Distances
(Port 1
Port 2)
Tx
Wavelength
(nm)
Rx Wavelength
(nm)
8642-0-x
MM 220/550m1850 850
MM 220/550m1850 850
8642-1-x
MM 220/550m1850 850
SM 12km 1310 1310
8642-2-x
MM 220/550m
1
850 850
SM 34km 1310 1310
8642-3-x
MM 220/550m1850 850
SM 80km 1550 1550
8643-2-x
SM 12km 1310 1310
SM 34km 1310 1310
8643-3-x
SM 12km 1310 1310
SM 80km 1550 1550
ST/SC iConverter 1000FF Single-Fiber Modules
8650-1-x
MM 220/550m1850 850
SM SF 20 km 1310
1550
8651-1-x
MM 220/550m
1
850 850
SM SF 20 km 1550 1310
8652-1-x
SM
12 km 1310 1310
SM SF 20 km 1310 1550
8653-1-x
SM 12 km 1310 1310
SM SF 20 km 1550 1310
8650-2-x
MM 220/550m
1
850 850
SM SF 40 km 1310 1550
8651-2-x
MM 220/550m
1
850 850
SM SF 40 km 1550 1310
8652-2-x
SM 12 km 1310 1310
SM SF 40 km 1310 1550
8653-2-x
SM 12 km 1310 1310
SM SF 40 km 1550 1310
1
62.5/125µm, 100/140µm multimode fiber up to 220m. 50/125µm
multimode fiber up to 550m. Refer to the fiber cable manufacturer for
multimode distance specifications.
iConverter
100FF Dual Fiber Modules
Connector
Fiber Type
(Port 1
Port 2)
Distances
(Port 1
Port 2)
Tx
Wavelength
(nm)
Rx
Wavelength
(nm)
ST/ST SC/SC
8620-1-x
8622-1-x
MM 5km
1310
1310
SM
30km
1310 1310
8620-2-x 8622-2-x
MM 5km 1310 1310
SM 60km 1310 1310
-
8622-3-x
MM
5km 1310
1310
SM 120km 1550 1550
ST/SC SC/SC
iConverter
100FF Single-Fiber Modules
8630-1-x 8634-1-x
MM 5 km 1310 1310
SM SF 20 km
1310
1550
8631-1-x 8635-1-x
MM 5 km 1310 1310
SM SF 20 km 1550 1310
8630-2-x 8634-2-x
MM 5 km 1310 1310
SM SF
40 km 1310
1550
8631-2-x 8635-2-x
MM 5 km 1310 1310
SM SF 40 km 1550 1310
8632-1-x 8636-1-x
SM
30 km 1310
1310
SM SF 20 km 1310 1550
8633-1-x 8637-1-x
SM 30 km 1310 1310
SM 20 km 1550 1310
8632-2-x 8636-2-x
SM SF 30 km
1310 1310
SM 40 km 1310 1550
8633-2-x 8637-2-x
SM 30 km 1310 1310
SM SF 40 km 1550 1310
iConverter
OC3FF Dual Fiber Modules
Connector
Fiber Type
(Port 1
Port 2)
Distances
(Port 1
Port 2)
Tx
Wavelength
(nm)
Rx
Wavelength
(nm)
ST/ST SC/SC
8660-1-x 8661-1-x
MM
5km 1310
1310
SM 30km 1310 1310
8660-2-x 8661-2-x
MM 5km 1310 1310
SM 60km 1310 1310
8661-3-x
MM
5km 1310
1310
SM 120km 1550 1550
ST/SC SC/SC
iConverter
OC3FF Single-Fiber Modules
8670-1-x
8674-1-x
MM
5 km 1310 1310
SM SF 20 km
1310 1550
8671-1-x 8675-1-x
MM 5 km 1310 1310
SM SF 20 km 1550 1310
8670-2-x 8674-2-x
MM 5 km 1310
1310
SM SF 40 km 1310 1550
8671-2-x 8675-2-x
MM 5 km 1310 1310
SM SF 40 km 1550 1310
8672-1-x 8676-1-x
SM 30 km
1310 1310
SM SF 20 km 1310 1550
8673-1-x 8677-1-x
SM 30 km 1310 1310
SM SF 20 km 1550 1310
8672-2-x 8676-2-x
SM
30 km 1310
1310
SM SF 40 km 1310 1550
8673-2-x 8677-2-x
SM 30 km 1310 1310
SM SF 40 km 1550 1310
multimode fiber up to 550m. Refer to the fiber cable manufacturer for
iConverter xFF Dual Fiber Modules
Connector
SFP
Fiber Type
(Port 1
Port 2)
Distances
(Port 1
Port 2)
Tx
Wavelength
(nm)
Rx Wavelength
(nm)
8699-0-x
-
-
- -
- - - -
Refer to the SFP data sheet for supported transceivers.
Model Type 100FF 1000FF OC3F F OC12FF xFF
Protocols
100BASE-FX,
100BASE-BX,
100BASE-LX
1000BASE-SX,
1000BASE-LX,
1000BASE-ZX,
1000BASE-BX
OC-3 OC -12
100BASE-FX,
1000BASE-X, OC-3,
OC-12, OC-48,
Fibre Channel 1x/2x/4x
Maximum
Data Rate
155Mbps 1.25Gbps 155Mbps 1.25Gbps 4.25Gbps
Fiber
Connectors
SC, ST,
Single-Fiber
SC
SC,
Single-Fiber
SC
SC, ST,
Single-Fiber
SC
SC,
Single-FiberSCSFP
Controls
Link Propagate, Remote Fault Detection
LED
Displa ys
Power,
Fiber Optic Link (2)
Dimensions
W:0.85" x D:4.5" x H:2.8"
Weight
8 oz.
Compliance
UL, CE, FCC Class A,
NEBS Level 3
Power
Requirement
(typical)
5-32VDC
0.3A @ 9VDC
(1.0A max)
Temperature
Standard: 0 to 50º C
Wide: -40 to 60º C
Storage: -40 to 80º C
Humidity
5 to 95%
(non-c ondens ing)
Altitude
-100m to 4000m
MTBF (hrs)
1,300,000
®
100FF, OC3FF, OC12FF, 1000FF and xFF
Standalone Fiber-to-Fiber Converter
User Manual
OVERVIEW:
The iConverter standalone ber-to-ber media converters
provide single-mode (SM) to multimode (MM), dual ber
to single-ber, wavelength conversion and ber extension.
Fixed-fiber models are available for Ethernet, Fast
Ethernet, Gigabit Ethernet and SONET/SDH applications.
The Small Form Pluggable (SFP) model is protocol
transparent and also supports Fibre Channel.
iConverter
OC12FF Dual Fiber Modules
Connector
8681-1-x
8681-2-x
8681-3-x
8690-1-x
8691-1-x
8692-1-x
8693-1-x
1
62.5/125µm, 100/140µm multimode fiber up to 220m. 50/125µm
multimode distance specifications.
Fiber Type
SC/SC
SC/SC
Distances
(Port 1
Port 2)
SM SF 20 km
SM SF 20 km 1550 1310
SM SF
SM SF 20 km 1550 1310
(Port 1
Port 2)
MM
220/550m11310 1310
SM 12km 1310 1310
MM 220/550m1 1310 1310
SM 34km 1310 1310
MM 220/550m
SM 80km 1550
iConverter
OC12FF Single-Fiber Modules
MM
220/550m
MM 220/550m
SM 12 km
20 km 1310 1550
SM 12 km 1310 1310
Tx
Wavelength
(nm)
1
1310 1310
1
1310 1310
1310 1550
1
1310 1310
1310 1310
Wavelength
Rx
(nm)
1550
Page 1 Page 2 Page 3 Page 4 Page 5 Page 6
LINK MODES:
The iConverter standalone ber-to-ber media converters
support two different linking modes.
LP
(a)
Switch 1
(b)
Switch 1 Converter A Converter B Switch 2
In Link Propagate (LP) mode (sometimes referred to as
Link Loss Carry Forward), a port transmits a Link signal
only when receiving a Link on the other front-plane port,
and a loss of a received Link at one port causes the other
front-plane port to stop transmitting its link signal. For
example, P1 transmits a Link only when receiving a Link
at P2 [Fig 1(a)].
In Remote Fault Detection (RFD) mode, a port transmits
a Link signal only when both itself and the other port are
receiving Link signals. A loss of a received Link signal at
a port is Looped-back and the port stops transmitting a
Link signal. The same loss of Link is propagated to the
other port which also stops transmitting the Link signal.
For example, the loss of Link into P2 causes both P1 and
P2 ports to stop transmission of the Link signal [Fig 1(b)].
Note: Connecting two adjacent converters which
are both set to RFD is not permitted and will cause a
“deadly embrace” lockup.
Converter A Converter B Switch 2
LP
LED Lit
LED Status depends on connected device
Fig. 1 Link Modes
Page 7 Page 8 Page 9 Page 10 Page 11 Page 12
LP
RFD
LED Off
FRONT PANEL DIP-SWITCH SETTINGS:
Left / Down Right / Up
Fig. 2 Front Panel Dip-Switches
Link Segment/Link Propagation “LS/LP” Dip-Switch:
This DIP-Switch has no effect. The LS function of this DIPSwitch has been disabled to enhance compatibility with
third-party ber optic devices. iConverter ber-to-ber media
converters normally operate in LP mode.
Remote Fault Detection Switch “RFD” Dip-Switch:
When in the Remote Fault Detection “RFD” position, the
Remote Fault Detection mode is enabled and LP mode
is disabled. When in the Normal “Norm” position (factory setting), Remote Fault Detection is disabled and LP
mode is enabled.
LED INDICATORS:
LED Color Description
Pwr: Yellow On--Power on
Lk/Rx (P1): Green On--Link Off--No Link
Lk/Rx (P2): Green On--Link Off--No Link
INSTALL STANDALONE MODULE AND
CONNECT CABLES
1. For wall-mounting, attach the converter to a wall,
backboard or other flat surface. For tabletop
installations, place the unit on a at surface. Attach the
rubber feet to the bottom of the converter to prevent
the unit from sliding. Make sure the unit is placed in a
safe, dry and secure location.
To power the unit using the AC/DC adapter, connect
the AC/DC adapter to an AC outlet. Then connect the
barrel plug at the end of the wire on the AC/DC adapter
to the 2.5mm DC barrel connector (center-positive) on
the unit. Conrm that the unit has powered up properly
by checking the power status LED located on the front
of the unit.
To power the unit using a DC power source, prepare a
power cable using a two conductor insulated wire (not
supplied) with a 14 AWG gauge minimum. Cut the
power cable to the length required. Strip approximately
3/8 of an inch of insulation from the power cable wires.
Connect the power cables to the unit by fastening the
stripped ends to the DC power connector.
Connect the power wires to the DC power source. The
Power LED should indicate the presence of power.
WARNING: Note the wire colors used in making the
positive and negative connections. Use the same color
assignment for the connection at the DC power source.
NOTE: If mounting with a safety ground attachment,
use the safety ground screw at the rear of the unit.
2. When using an SFP model (8699-0), insert the SFP
Fiber transceiver into the SFP receptacle on the
module.
Note: The release latch of the SFP Fiber transceiver
must be in the closed position before insertion. The
transceivers installed must have matching speeds
to operate.
3. Attach an appropriate multimode or single-mode ber
cable to each ber connector. The transmit cable (Tx)
must attach to the receive side on the other device; the
receive cable (Rx) must attach to the transmit.
4. When using single-ber (SF) models, the Tx wavelength
on one end must match the Rx wavelength on the other
and the converters must be used in matched pairs
(example: model 8670-1 must be matched with model
8671-1).
SPECIFICATIONS:
Warning
The operating description in this Instruction Manual is for
use by qualied personnel only. To avoid electrical shock,
do not perform any servicing of this unit other than that
contained in the operating instructions, unless you are
qualied and certied to do so by Omnitron Systems
Technology, Inc.
Warranty
This product is warranted to the original purchaser against
defects in material and workmanship for a period of 2
YEARS from the date of shipment. A LIFETIME limited
warranty may be obtained by the original purchaser by
REGISTERING this product with Omnitron within 90
days from the date of shipment. To register, complete
and mail or fax the enclosed Registration Card to the
indicated address. You may also register your product
on the internet at www.omnitron-systems.com/Register.
During the warranty period, Omnitron will, at its option,
repair or replace a product which is proven to be defective.
For warranty service, the product must be sent to an
Omnitron designated facility, at Buyer’s expense. Omnitron
will pay the shipping charge to return the product to Buyer’s
designated US address (within the 48 contiguous states
and the District of Columbia) using Omnitron’s standard
shipping method.
Limitation of Warranty
The foregoing warranty shall not apply to defects resulting
from improper or inadequate use and/or maintenance
of the equipment by Buyer, Buyer-supplied equipment,
Buyer-supplied interfacing, unauthorized modications
or tampering with equipment (including repairs of
equipment by personnel not specically authorized and
certied by Omnitron, or misuse, or operating outside the
environmental specication of the product (including but not
limited to voltage, ambient temperature, radiation, unusual
dust, etc.), or improper site preparation or maintenance.
No other warranty is expressed or implied. Omnitron
specifically disclaims the implied warranties of
merchantability and tness for any particular purpose.
Exclusive Remedies
The remedies provided herein are the Buyer’s sole and
exclusive remedies. Omnitron shall not be liable for any
direct, indirect, special, incidental, or consequential
damages, whether based on contract, tort, or any legal
theory.
Technical Support:
For help with this product, contact our Technical Support:
Phone: (949) 250-6510
Fax: (949) 250-6514
Address: Omnitron Systems Technology, Inc.
38 Tesla
Irvine, CA 92618 USA
E-mail: support@omnitron-systems.com
URL: www.omnitron-systems.com
Form: 040-08600-001B 5/14