FlexPointTM 232 User Instructions
Description:
The FlexPointTM 232 converts between asynchronous RS-232 and fiber with baud-rate auto-sensing, supporting speeds of up to 115,200 baud. The following multimode (MM) and single-mode (SM) models are described here:
Model Fiber Distances
4480 MM, SC 2.5 km 4481 MM, ST 2.5 km 4482 MM, SC 5 km 4483 MM, ST 5 km 4484 SM, SC 30 km 4485 SM, ST 30 km 4486 SM, LH, SC 60 km 4489-2 SM, LC 30 km
Power Adapter Notice:
1. When used in a stand-alone configuration, this product is intended to be and must be used only with a Listed Direct Plug-In Power Unit marked “Class 2” and rated at 9Vdc, 1 Amp.
2. This product should always be used only with Omnitron Supplied Power Unit model number 9113-PS.
Before inserting the Power Adapter, verify that
the power on the unit is appropriate for your AC
WARNING!
line voltage source.
Mounting and Cable Attachment:
The FlexPoint 232 can be solo-mounted using a wall­mounting kit or the DIN-rail kit. It can also be rack-mounted using a 5-position shelf or a high-density 14-unit FlexPoint Powered Chassis.
RS-232 Cable Attachment:
Attach the FlexPoint 232 port via a male DB9 terminated or unterminated straight through RS-232 serial cable to a DTE or DCE device.
Note: Use RS-232 cables that are compliant with the specifications that are outlined in RS-232 cable specifications.
Fiber Optic Cable Attachment:
Connect the fiber cables between the two FlexPoint 232 converters. The transmit (Tx) must attach to the receive side and the receive (Rx) must attach to the transmit side.
Note: Use fiber cables that are compliant with the specifications that are outlined in fiber cable specifications.
Switch Settings: “DB9 to DTE/DCE” Switch:
When connecting the RS-232 cable to terminal equipment such as a computer or controller, set the switch to “DB9 to DCE” (down, factory setting). When connecting to communication equipment such as a modem or printer, set the switch to “DB9 to DTE” (up).
(Please refer to pin assignments for more detailed information)
“Fiber Loopback” Switch:
This switch will allow the entire fiber segment to be tested at either of the FlexPoint 232 converters without having to set switches on both units simultaneously. When the switch is
set to “Fiber Loopback”, the local unit’s fiber Tx port will be encoded to carry a remote loopback protocol over the fiber cable. This remote loopback protocol will set the far end FlexPoint 232 converter to a loopback mode of operation and return a signal over the fiber cable to the originating unit. An LED on the local and remote FlexPoint 232 converters will blink fast to show a confirmation that the fiber segment is communicating properly between the converters. A slow blink will indicate an error condition over the fiber segment. By returning the switch to the “normal” position the converters will resume to normal operation.
Fiber Cable Specifications:
Multimode (standard)
Cable: 50/125, 62.5/125, 100/140 μm Wavelength: 850nm Max Distance: 2.5 km
Multimode (long-haul)
Cable: 50/125, 62.5/125, 100/140 μm Wavelength: 1310nm Max Distance: 5 km
Singlemode
Cable: 9/125 μm Wavelength: 1310nm Max Distance: 30 km
Singlemode (long-haul)
Cable: 9/125 μm Wavelength: 1310nm Max Distance: 60 km
RS-232 Cable Specifications:
Gauge 22 to 24 AWG Mutual Capacitance 12 to 50 pF/ft. Maximum distance 15.2 m/50 ft.
User Warranty Registration
Omnitron Systems Technology, Inc.
140 Technology Drive
Irvine, CA 92618, USA
Fax: (949) 250-6514
Please register on-line @ http://www.omnitron-systems.com or complete both sides
and mail or fax this registration form to:
Name: _________________________________________________
Company: ______________________________________________
Address: ______________________________________________
Please complete both sides of this form
______________________________________________
City: ___________________ State: _______ Zip Code: _ __ __ __ _
Country: _______________________________________________
Phone: ____________________ Fax: _______________________
E-mail:_________________________________________________
LED Indicators:
LED Color Function Description Power: Yellow Solid Power applied DTE/DCE: Green Solid DTE selected
Yellow Solid DCE selected DB9/232: Green Solid/Blink Link / Data received Fiber Link: Green Solid Link
Green Blink fast Fiber loop-back is good
Green Blink slow Error in fiber loop-back
Switches:
Description Function DB9 to DTE / DCE: Data Terminal / Data Communication Fiber Loop-back: Loop-back / Normal
FlexPoint 232 Pin Assignments
RI 9
CTS 8
RTS 7
DSR 6
PIN PIN SIGNAL ABBR DTE DCE
1 D ata Ca rrier Dete ct DCD IN OUT 2 Received Data RD IN OUT 3Transmitted Data TD OUT IN 4 Data Terminal DTR OUT IN 5 Si g n a l Gr o und SGND - ­6 Data Set Ready DSR IN OUT 7 Re q uest To Send RTS OUT IN 8Clear To Send CTS IN OUT 9Ring Indicator RI IN OUT
5 SGND
4 DTR
3TD
2RD
1 DCD
Warning
The operating description in this Instruction Manual is for use by qualified personnel only. To avoid electrical shock, do not perform any servicing of this unit other than that contained in the operating instructions, unless you are qualified and certified to do so by Omnitron Systems T echnology , Inc.
Caution
All user-required operations can be performed without opening the unit. Never attempt to open or remove the cover or tamper with the unit.
Warranty
This product is warranted to the original purchaser against defects in material and workmanship for a period of TWO YEARS from the date of shipment. A LIFETIME warranty may be obtained by the original purchaser by REGISTERING this product with Omnitron within 90 days from the date of shipment. TO REGISTER, COMPLETE AND MAIL OR FAX THE REGISTRATION POR TION OF THIS INSTRUCTION MANUAL TO THE INDICATED ADDRESS. Or you may register your product on the internet at http:// www.omnitron-systems.com. During the warranty period, Omnitron will, at its option, repair or replace a product which is proven to be defective.
For warranty service, the product must be sent to an Omnitron designated facility, at Buyer’s expense. Omnitron will pay the shipping charge to return the product to Buyer’s designated US address using Omnitron’s standard shipping method.
The foregoing warranty shall not apply to defects resulting
Limitation of Warranty
from improper or inadequate use and/or maintenance of the equipment by Buyer, Buyer-supplied equipment, Buyer-supplied interfacing, unauthorized modifications or tampering with equipment (including removal of equipment cover by personnel not specifically authorized and certified by Omnitron), or misuse, or operating outside the environmental specification of the product (including but not limited to voltage, ambient temperature, radiation, unusual dust, etc.), or improper site preparation or maintenance. No other warranty is expressed or implied. Omnitron specifically disclaims the implied warranties of merchantability and fitness for any particular purpose.
Exclusive Remedies
The remedies provided herein are the Buyer’s sole and exclusive remedies. Omnitron shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any legal theory.
Technical Support:
For help with this product, contact our Tech. Support: Phone: (949) 250-6510 Fax: (949) 250-6514 Address: Omnitron Systems Technology, Inc.
140 Technology Drive
Irvine, CA 92618 USA E-mail: support@omnitron-systems.com URL: http://www.omnitron-systems.com
Form: 040-04480-001C 12/12
User Warranty Registration
Please register on-line @ http://www.omnitron-systems.com or complete both sides
and mail or fax this registration form to:
FlexPoint Type: 232, Fiber Type:_______Connector: _______
Model: _________________________________________________
Serial Number: ______________ Purchase Date:______________
Purchased From: _________________________________________
Address: ______________________________________________
City: ___________________ State: _______ Zip Code: ________
Please complete both sides of this form
______________________________________________________
Country: _______________________________________________
______________________________________________________
Comments and Suggestions: _______________________________
Loading...