Omnitron Systems Technology 10/100/1000 UTP to 100/1000X Ethernet Media Converter FlexPoint GX/T, FlexPoint GX/T User Manual

Page 1 Page 2 Page 3
Page 4 Page 5 Page 6
Fiber Type Distance
Connector Type
ST SC SFP
SFP -
- - 4719-x
MM 220 / 550m
4706-x 4700-x -
SM 12km
4707-x 4701-x -
SM 34km
- 4702-x -
SM 80km
- 4703-x -
SM 110km
- 4704-x -
SM 140km
- 4705-x -
SM-SF
1310/1550
20km
- 4710-x -
SM-SF
1550/1310
20km
- 4711-x -
SM-SF
1310/1550
40km
- 4712-x -
SM-SF
1550/1310
40km
- 4713-x -
Power Adapter Kits (-x):
-0 = No power adapter included
-1 = 110-120 VAC/60 Hz (US plug)
-2 = 100-240 VAC/50-60 Hz (IEC plug, no power cord)
For other power and fiber configurations, contact the factory.
1
62.5/125µm, 100/140µm multimode fiber up to 220m, 50/125µm multimode fiber up to 550m. Refer to the fiber cable manufacturer for multimode distance specifications. Single-Fiber converters must be used in pairs. The Tx wavelength on one end has to match the Rx wavelength on the other.
POWER ADAPTER NOTICE:
1. This product should only be used with Omnitron Supplied Power Unit model numbers 9113-PS [US] or 9115-PS [Universal].
2. When used in a standalone configuration, this product must be used with a Listed Direct Plug-In Power Unit marked “Class 2” and rated at 9VDC, 1 Amp.
NOTE: If mounting with a safety ground attachment, use the safety ground screw at the rear of the unit.
NOTE: Remove safety ground screw when installing the module in the 14-Module Chassis or when using
FlexPoint™ GX/T
10/100/1000 UTP to 100/1000X
Ethernet Media Converter
User Manual
DESCRIPTION:
The FlexPoint GX/T is a 10/100/1000BASE-T UTP to 1000BASE-X fiber media converter that supports jumbo frames up to 10,240 bytes. The GX/T features Small Form Pluggable (SFP) transceivers that support both 100BASE-FX and 1000BASE-X for interoperability with Gigabit and Fast Ethernet fiber equipment.
Both the fiber port and the UTP port support auto­negotiation, an IEEE standard which defines how all the communicating devices automatically perform their configuration functions.
The auto-negotiation feature can be disabled on both ports (for manual configuration) using DIP-switches on the product. This is useful in a situation where the GX/T is connected to a non-negotiating device and the configuration parameters must be set manually.
it with the DC-DC Converter (Model # 4384)
WARNING!
Before inserting the Power Adapter, verify that the power on the unit is appropriate
for your AC line voltage source.
INSTALLATION PROCEDURE
1.) Configure the appropriate FlexPoint GX/T DIP-Switch settings.
2.) Connect the UTP port via a Category 5 or better cable to a 10BASE-T, 100BASE-TX or 1000BASE-T Ethernet device.
3.) When using fixed fiber port models, connect the appropriate multimode or single-mode fiber cable to the fiber port of the installed module. It is important to ensure that the transmit (Tx) is attached to the receive side of the device at the other end and the receive (Rx) is attached to the transmit side. Single-fiber (SF) media converter models operate in pairs. The Tx wavelength must match the Rx wavelength at the other end and the Rx wavelength must match the Tx wavelength at the other end.
4.) When using a GX/T SFP model, insert the SFP Fiber transceiver into the Port 1 SFP receptacle on the GX/T.
NOTE: The release latch of the SFP Fiber transceiver must be in the closed (up) position before insertion.
LOOPBACK
The FlexPoint GX/T has the capability to provide loopback to aid in installation and maintenance. A DIP-switch is used to enable loopback on the module (see page 7). Figure 1 shows the module in normal and loopback modes.
TX
RX
RX
TX
UTP
Fiber
NormalMode
FlexPointGX/T
TX
RX
RX
TX
UTP
Fiber
LoopbackMode
Figure 1: Loopback Mode
LINK MODES
In order to accommodate different user needs, the GX/T supports four different link modes (see Fig. 2).
In Link Segment (LS), a port transmits a Link signal independently of any received Link at any other port. For example, the UTP transmits a Link regardless of the fiber receiving a Link [Fig. 2(a) & (b)].
In Link Propagate (LP), a port transmits a Link signal only when receiving a Link at its other port. For example, the UTP transmits a Link only when receiving a Link at the fiber port [Fig. 2(c)].
In Remote Fault Detection + Link Segment (RFD+LS), the fiber port transmits a Link signal only when receiving a Link at the fiber port. As a result, fiber faults (no Link received at the fiber) are looped-back and can be reported to the network core [Fig. 2(d)].
In Remote Fault Detection + Link Propagate (RFD+LP), the UTP port transmits a Link signal only when receiving a Link at the fiber port. The fiber port transmits a Link signal only when receiving Link signals at both the fiber port and the UTP port. As a result, fiber faults (no Link received at the fiber) are propagated forward and looped back for fault reporting at both the network core and the customer location [Fig. 2(e)].
NOTE: Connecting two converters with both set to RFD mode is not supported and will cause a “deadly embrace” lockup.
Switch 1 Converter A Converter B Switch 2
(a)
LS
Fiber
UTP
UTP
Fiber
LS
Switch 1 Converter A Converter B Switch 2
LS
(b)
LS
(c)
Switch 1 Converter A Converter B Switch 2
LP
LP
(d)
Switch 1 Converter A Converter B Switch 2
LP
RFD+LS
(e)
Switch 1 Converter A Converter B Switch 2
LP
RFD+LP
LED On LED Status depends on connected device
LED Off
Figure 2: Link Modes
Warning
The operating description in this Instruction Manual is for use by qualified personnel only. T o avoid electrical shock, do not perform any servicing of this unit other than that contained in the operating instructions, unless you are qualified and certified to do so by Omnitron Systems Technology, Inc.
Caution
All user-required operations can be performed without opening the unit. Never attempt to open or remove the cover or tamper with the unit.
Warranty
This product is warranted to the original purchaser against defects in material and workmanship for a period of TWO YEARS from the date of shipment. A LIFETIME warranty may be obtained by the original purchaser by REGISTERING this product with Omnitron within 90 days from the date of shipment. TO REGISTER, COMPLETE AND MAIL OR FAX THE REGISTRATION PORTION OF THIS INSTRUCTION MANUAL TO THE INDICATED ADDRESS. Or you may register your product on the internet at http://www.omnitron-systems.com. During the warranty period, Omnitron will, at its option, repair or replace a product which is proven to be defective. For warranty service, the product must be sent to an Omnitron designated facility, at Buyer’s expense. Omnitron will pay the shipping charge to return the product to Buyer’s designated US address using Omnitron’s standard shipping method.
Limitation of Warranty
The foregoing warranty shall not apply to defects resulting from improper or inadequate use and/or maintenance of the equipment by Buyer, Buyer-supplied equipment, Buyer­supplied interfacing, unauthorized modifications or tampering with equipment (including removal of equipment
cover by personnel not specifically authorized and certified by Omnitron), or misuse, or operating outside the environmental specification of the product (including but not limited to voltage, ambient temperature, radiation, unusual dust, etc.), or improper site preparation or maintenance.
No other warranty is expressed or implied. Omnitron specifically disclaims the implied warranties of merchantability and fitness for any particular purpose.
Exclusive Remedies
The remedies provided herein are the Buyer’s sole and exclusive remedies. Omnitron shall not be liable for any direct, indirect, special, incidental, or consequential damages, whether based on contract, tort, or any legal theory.
TECHNICAL SUPPORT:
For help with this product, contact our Tech. Support: Phone: (949) 250-6510 Fax: (949) 250-6514 Address: Omnitron Systems Technology, Inc.
140 Technology Drive, #500
Irvine, CA 92618 USA E-mail: support@omnitron-systems.com URL: http://www.omnitron-systems.com
Form: 040-04700-001A 8/08
SPECIFICATIONS
LED INDICATORS
Page 7
Page 9
Page 10 Page 11
Page 12
LED Function
"Legend"
Color Off State
On / Blinkin g State
Power / Test "Power"
Green No power
On: Module has power Blinking: Module in loopback
mode
F/O AN "F/O-Auto-Neg"
Green
Port confi gured for manual negotiation
On: Fiber port configured for AN Blinking: Fiber port configured for
AN but in manual mode
F/O Speed 100* "F/O-100"
Green
Not connected at 100Mbps
On: Fiber port linked at 100Mbps Blinking (10Hz): Link activity at
100Mbps Blinking (1 H z ): Signal detected
but port unable to establish a link
F/O Speed 1000 "F/O-1000"
Green
Not connected at 1000Mbps
On: Fiber port linked at 1000Mbps Blinking (10Hz): Link activity at
1000Mbps Blinking (1 H z ): Signal detected
but port unable to establish a link Pattern Blinking: AN remote Fault bit detected
UTP Duplex "UTP-FDX"
Green Half-D uplex
On: UTP port in Full-Duplex
UTP AN "UTP-Auto-Neg"
Green
Port confi gured for manual negotiation
On: UTP por t c onfigured f or AN Blinking: UTP port configured for
AN but in manual mode
UTP Speed 100 "UTP-100"
Green
Not connected at 100Mbps
On: UTP port linked at 100Mbps Blinking (10Hz): Link activity
UTP Speed 1000 "UTP-1000"
Green
Not connected at 1000Mbps
On: UTP port linked at 1000Mbps Blinking (10Hz): Link activity
UTP Speed 10 "UTP-100" + "UTP-1000"
Green
Not connected at 10Mbps
On: UTP port linked at 10Mbps Blinking (10Hz): Link activity
Pattern Blinking: (1Hz ): Detecting
"remote_fault" (AN) on UTP port
"UTP Auto-Neg" + "UTP-100" + "UTP-1000"
Green -
Blinking (1 H z ): Unable to establish AN link on the UTP port
*SFP models only
Model Type GX/T
Protocols
IEEE 802.3
10BASE-T, 100BASE-TX, 1000BASE-T, 100BASE-FX,
1000BASE-X
Frame Size
10,240 byte max. frame size
UTP Cable
RJ-45, Category 5 and higher
Fiber Cables
Multimode: 50/125, 62.5/125, 100/140µm
Single-mode: 9/125µm
UTP Connectors
RJ-45
Fiber Connectors
ST, SC, LC (SFP)
DIP-Switches
Fiber: Auto-Neg, 1000, 100
UTP: Auto-Neg, 10, 100, 1000, FDX/HDX, Pause En/Dis
Loopback, Link Seg, Link Prop, Remote Fault Det.
LED Displays
Power, Fiber AN, Fiber Speed/Activity, UTP Speed/Activity,
Full/Half-Duple x
Dimensions
W: 3.0" x D: 4.0" x H: 1.0"
Weight
6 oz. (without power adapter)
Compliance**
UL, CE, FCC Class A
Barrel
Connector
Molex
Connector
Power Requirements
Nominal Voltage:
Voltage Range:
Nominal Power:
Maximum Power:
9VDC
5.0 to 32.0VDC
0.3A @ 9VDC 1A @ 9VDC
5VDC
5.0 to 32.0VDC
0.5A @ 5VDC
0.75A @ 5VDC
Temperatu re
0 to 50
o
C
Humidity
5 to 95% (non-condensing)
Altitude
-100m to 4000m
MTBF (Hours)
Module without Power Adapter: 900,000 Module with Power Adapter -1: 250,000 Module with Power Adapter -2: 100,000
DIP-SWITCHES
F/O Manual/Auto “MAN/AN” DIP-Switch:
Setting this DIP-Switch to P1 Auto-Negotiate “AN” (factory setting) enables the Fiber Port to determine duplex mode automatically. If the connected device cannot provide the proper signal to indicate its own mode of operation, this DIP-Switch should be set to P1 Manual “MAN.” This feature allows connections with legacy devices that do not support auto-negotiation.
NOTE: When the fiber port is in Manual Mode, a link-up may not occur with other devices. Both devices must be set to the same mode (either Manual or Auto-Negotiate) for the link-up to occur.
When set to auto-negotiation, the fiber port will automatically reconfigure to manual mode when an auto­negotiation connection cannot be established.
F/O Speed “100/1000” DIP-Switch:
The GX/T supports 100BASE-FX and 1000BASE-X SFPs. This DIP-switch is used to configure the unit for the speed of SFP used. Setting this DIP-switch to “1000” enables the fiber port is accept 1000BASE-X SFPs. Setting this DIP-switch to “100” enables the fiber port to accept 100BASE-FX SFPs. This DIP-switch is only available on the SFP model.
This DIP-switch is ignored when using Omnitron branded SFPs. The GX/T automatically configures the fiber port to the correct speed.
UTP Configuration DIP-Switches:
See the UTP Modes table on page 8.
Pause “On/Off” DIP-Switch:
In auto-negotiation mode, setting this DIP-switch to “On” allows the unit to advertise as Symmetrical and Asymmetrical Pause capability. In auto-negotiation mode,
setting the DIP-switch to “Off” causes the unit to advertise no Pause capability. In the manual mode, this DIP­switch determines the Symmetrical Pause behavior.
Loopback “Off/On” DIP-Switch:
Setting this DIP-switch “On” enables loopback on the fiber and UTP ports (see Figure 1).
Link Modes:
See the following table for configuring link modes:
SW9
"LS/LP"
SW10
"RFD/Normal"
Result
LS Normal Enables Link Segment mode (LS). LP Normal Enables Link Propagate mode (LP).
LS RFD
Enables Remote Fault Dete ction mode plus Link Segment mode (RFD+LS).
LP RFD
Enables Remote Fault Dete ction mode plus Link Propagation mode (RFD+LP).
NOTE: RFD is only available when the fiber port is operating in manual mode.
REMOTE FAULT
Each port will generate an “IEEE remote_fault indicator” when the incoming signal to the port is lost. When a port is configured for auto-negotiation, it will set the remote fault bit “high” in the AN advertisement when the port detects a loss of incoming signal. See LED Indicators table on page 9 for specifics on how the unit reports the detection of this signal.
When the fiber port is operating in 100BASE-FX, a loss of incoming signal will cause the port to generate a Far-End­Fault indicator pattern. See LED Indicators table on page 9 for specifics on how the unit reports the detection of this signal.
UTP MODES
SW3
AN/MAN
SW4
10/100/
1000
SW5
10/100
SW6
FDx/HDx
UTP Mode of Operation
AN 1000 NA FDX Configured for Auto Negotiation.
(1000F, 1000H, 100F, 100H, 10F, 10H)
AN 1000 NA HDX Configured for Auto Negotiation.
(1000H, 100F, 100H, 10F, 10H)
AN 10-100 100 FDX Configured for Auto Negotiation.
(100F, 100H, 10F, 10H)
AN 10-100 100 HDX Configured for Auto Negotiation.
(100H, 10F, 10H)
AN 10-100 10 F DX Co nfigured for Auto Negotiation.
(10F, 10H)
AN 10-100 10 HDX Configured for Auto Negotiation.
(10H)
MAN 1000 NA FDX Configured for Auto Negotiation.
(1000F)
When the port is set to 1000, it is always in AN mode.
MAN 1000 NA HDX Configured for Auto Negotiation.
(1000H)
When the port is set to 1000, it is
always in AN mode. MAN 10-100 100 FDX Port forced to 100 FDX MAN 10-100 100 HDX Port forced to 100 HDX MAN 10-100 10 FDX Port forced to 10 FDX MAN 10-100 10 HDX Port forced to 10 HDX
When the module is configured for auto-neg o tiation, the module will advertis e i n the order shown in the parenthesis.
Page 8
Loading...