Thank you for a buying product. Read this manual first as it will help you operate the system properly. Please keep this manual
for future reference.
WARNING:
ATTENTION:Don't refit the system or spare parts without being authorized as this will .void the warranty
WARNING: Don't (such as candles) the equipment.place naked flamesclose to
Read the instruction first before using this product.
1.
Please keep this manual for future reference
2.
Pay attention to all warnings.
3.
Obey all operating instructions.
4.
Do not expose this product to rain or moisture.
5.
Clean this equipment with a dry cloth.
6.
Do not block any ventilation openings. Install according to instructions .
7.
Do not install this product near any heat source, such as , heater, burner, or any other equipment with heat radiation .
8.
Only use spare parts by manufacturer.
9.
Pay attention to the safety symbol on the of the cover.
10.
This product must be installed by professionals. When using hanging brackets or rigging other than those supplied with
the product, please ensure they comply with the local safety codes.
The exclamation point within an equilateral triangle is intended to alert you to the presence of important
operating and servicing instructions.
manual
manufacturer's
a
supplied the
outside
1
Page 3
T4.4
T ser ies ful l range spe aker lin e array col umn
CONTENT
CONTENT
PRODUC T INTRODUCTION
Main Features
Product Description
Applications
CONNECTION
Push Terminals
System Reference Diagram
INSTALLATION
Optional Installation Accessories
Installation Options
TECHNICAL SPECIFICATIONS
Specifications
Frequency Response and Impedance Cur ve
Dimensions
3
3
3
3
4
4
4
5
5
5
6
6
6
7
Product information updated without
notification, please visit www.elderaudio.com for
latest update.
may be
2
Page 4
PRODUCT INTRODUCTION
T4.4
4 x 4 li ne array full range column speaker
Main Features
A vertical line array of 4 x 4" full range transducers providing
high fidelity sound
Frequency response 90H z-16KH z(-3dB).
Sensitivity 92dB, Max SPL 113dB.
Dispersion 180 x 30 .
Rated power 120w, max power 480w.
Plywood cabinet with durable .textured paint finish
Can be installed alone or stacked in multiples using the
optional accessories.Suitable for many venues including
inside and outside undercover environments.
Patents pending for central diffuser plate.
o
T ser ies ful l range spe aker lin e array col umn
T4.4
Designed for high speech intelligibility and natural
sounding music.
Quick install U bracket included.
Product Description
β3
The T4.4 line array full range column speaker is one
o three speakers in the T Series. This attractively designed, f
120 W RMS , in no vat ive s pea ke r d eli vers hig h spe ech
intelligibility and natural sounding music in a wide range
of applications through its 4" full range drivers. A ver tical
line array of 4 drivers provides control over a hori zontal
and vertical pattern of 180 x 30 and reproduces the critical
vocal range 90Hz-1 6kHz without requi ring a proc essor.
A dif fu se r plate (patent p en di ng ) is fitted t o the centre
d river s t o a ss ist wi th t he vertical pa tte rn c on tro l.
The T4.4 sp eaker can either be used in singles, mul tiples
or stacked using the optional accessories in many indoor
applications such as Houses of Worship, Shopping Malls,
Transport Terminals, Theme Parks, Meeting Rooms, Schools,
Small Auditoriums. When stacking the T4.4 end on end to
create a taller line a rray the height of the line array must
correspond to the ear height range of the listeners in both
seated or standing positions.
The T4.4 is manufactured from 15 mm plywood meeting a
tensile strength of 3500N and is finished in either black or
white using a very durable textured paint. The metal speaker
grill is powder coated and passes all rust resistance tests.
oo
Adding the optional line transformer accessory makes the
T4.4 line array speaker very versatile in 70/100v systems.
To enhance the already great performance of the T4.4 you
can use the EQ filters provided.
Applications
churches/temples
multifunction halls
meeting rooms
schools
small auditoriums
shopping malls
transport terminals
The T4.4 is shipped with a quick install U bracket.
theme parks
3
Page 5
T4.4
T ser ies ful l range spe aker lin e array col umn
CONNECTION
The T4.4 rear panel has two input connectors. You can choose to use either the 4 way push terminal connector or the NL4
speakon connec tor. The two connectors are paralleled for through connection.
Push Terminals
1+1-
Speakon NL4
2+2-
1-
2+
1+
2-
System Reference Diagram
Processor (Optional EQ curves available on CD)
21
INPUT
LIMITER
POWE R
COMP
OVER
MUTE
OVER
-6
-10
-20
-40
-6
-10
-20
-40
MUTEMUTEMUTEMUTEMUT EMUT EMUTE
INPUT
MODE
SIGNAL GND
PIN1:
SIGNAL +
PIN2:
PIN3:
SIGNAL -
LIMITER
IN-1
IN-1
OVER
IN-2
IN-2
-6
HF
HF
-10
MF
MF
-20
LF
LF
-40
SLF
SLF
CHA
BRIDGE IN
LFFILTER
CLIPLIM ITER
BRIDGE
50HZ
PARALLEL
25HZ
5HZ
STEREOON
Serial n o:
OUTPUT ASSI GNMEN T:
CHA:
BRIDGE MON O OUTPU T:
CHB
CHA :
1+ 1- INPUT
CBADEF
OUTPUT
LIMITER
LIMITER
LIMITER
IN-1
OVER
-10
-20
-40
OFF
PIN 1+ :
PIN 1 - :
PIN 2+ :
PIN 2 - :
PIN1+ : SIGNAL
IN-1
OVER
IN-2
IN-2
OVER
-6
-6
HF
MF
LF
SLF
GROUND
CHA SIGNAL
CHA GND
CHB SIGNAL
CHB GND
-6
HF
-10
-10
MF
-20
-20
LF
-40
-40
SLF
OFF
ON
BRIDGE
CHB SIGNAL
CHB:
PIN 1+ :
CHB GND
PIN 1 - :
PIN 2+ :
PIN 2 - :
PIN2+ :
GND
+
LOW
2+
-
1+
1+
NL4
1-
1-
+
-
+
-
LOW
LOW
2-
+
LOW
-
RECALL
UP
FUSE
POWER
CABLE
/ENTER
DISPLAY
DOWN
IN-1
IN-2
HF
MF
LF
SLF
CHA OUTPU T
CHB OUTPU T
PROGRAM
STATUS
REMOTE/ID
LOCK
!
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
Special design for big power!
LIMITER
IN-1
OVER
IN-2
-6
HF
-10
MF
-20
LF
-40
SLF
-
A
+
+
-
+
B
-
T4.4
Warning: Please make sure the speaker impedance and polarity match the amplifiers.
4
T4.4
Page 6
INSTALLATION
T ser ies ful l range spe aker lin e array col umn
T4.4
Optional Installation Accessories
The T4.4 cabinet has 3 flying points, plus a stand mount
ad ap tor to ensure fast and easy i ns ta ll ation. To install
stacked speakers there are an optional coupling brackets.
1.Wall bracket
2.Speaker coupling brackets
Installation Options
1.Flying
Ceiling mount
2. Stand mount
Extensi on moun t
Wall m ount
3. Speaker c ou pling
3.Stand mount adaptor
4.Tripod
Warning: Always ensure the mounting accessories
safety factor is not less than 5:1 or that it meets the
local standards.
5
Page 7
T4.4
T ser ies ful l range spe aker lin e array col umn
TECHNICAL SPECIFICATIONS
Specifications
Product:
Transducer:
Frequency Response(-3dB):
Frequency Response(-10dB):
Sensitivity(1W@1m):
Maximum. SPL(1m):
Power:
Dispersion Angle HxV():
Rated Impedance:
Cabinet:
Installation:
Paint:
Grill:
Connec tor :
Dimension(WxDxH):
Packing Dimension(WxDxH):
Net Weight:
Gross Weight:
Optional Accessories:
Passive Wooden Speaker
4 x 4'' Full range transducers
1
90Hz-16kHz
80Hz-17kHz
2
92dB
3
113dB/119dB ()PEAK
120W (RMS)
4
240W (MUSIC)
480W (PEAK )
°
180 x 30
°
8 ohms
15mm plywood construction
Mounting U bracket included and
optional mounting points provided.
White durable textured fini sh
White powder coated ,
0.8mm steel mesh.
4-Push terminal and 1 NL4 Speak on
135x169x560mm
(5.3x6.7x22.0in)
240x205x660mm
(9.4x8.1x26.0in)
6.5kg (14.3 lbs)
7.0kg (15.4 lbs)
Coupling bracket, Stand adaptor,
Tripod
Speaker Testing Method
1. Frequency Response
Use Pink noise to test the speaker in the anechoic chamber, adjust the
level to make the speaker work at its rated impedance and set the output
power at 1W, then test the frequency response 1m away from the
speaker.
2. Sensitivity
Use full range Pink noise which has been modified using an EQ
cur ve to test the speaker in the anechoic chamber, increasing the
signal to make the speaker work at its rated impedance and set the
power outp ut at 1W, t hen test the sensiti vity 1m away from the
speaker.
3. MAX.SPL
Use full range Pink noise which has been modified using a n EQ
curve to test the speaker in the anechoic chamber , increase the
si gna l to mak e the sp eaker work at it s maxim um power output
level, then test the SPL1m away from t he speaker.
4. Rated Power
Us e Pi nk noise to the IEC# 26 8- 5 st andard to test the speaker,
i ncrease the signal for a continuous peri od of 1 00 hours, the
rated power is the power whe n th e spe aker will show no v isib le
or measurable damage.
Technical Specifications
110
100
90
80
Sensitivity (dB)
70
60
20
6
Frequency response curve (with control)
Frequency response curve (without control)
Impedance curve
50100200500
1k
Frequency (Hz)
2k
5k10k20k
90
50
25
15
7.5
4
Impedance (Ohms)
Page 8
TECHNICAL SPECIFICATIONS
Dimensions
[6.65in]
169mm
Top view
135mm
[5.32in]
T ser ies ful l range spe aker lin e array col umn
T4.4
280mm
70mm
[11.02in]
[2.76in]
Side view
Front view
560mm
[22.05in]
Bottom view
93mm
[3.66in]
Back view
52mm
[2.05in]
7
Page 9
Notes:
Page 10
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.