OMNIREL OM1905STM, OM1912STM, OM1915STM, OM1915NTM, OM1912NTM Datasheet

...
OM1905STM OM1905NTM
OM1912STM OM1912NTM
ISOLATED HERMETIC FIXED VOLTAGE NEGATIVE REGULATORS APPROVED TO DESC DRAWINGS
Three T erminal, Fixed V oltage, 1.5 Amp Precision Negative Regulators In Hermetic JEDEC TO-257AA P ackage
FEATURES
• Isolated Hermetic Package, JEDEC TO-257AA Outline
• Output Voltages: -5V, -12V, -15V
• Output Voltages Set Internally to ±1%
• Built-In Thermal Overload Protection
• Short Circuit Current Limiting
• Product Is Also Available In Non-Isolated Package
• Similar To Industry Standards 7905, 7912, 7915
OM1915STM OM1915NTM
DESCRIPTION
These three terminal negative regulators are supplied in a hermetically sealed metall package whose outline is similar to the industry standard TO-220 plastic package. All protective features are designed into the circuit, including thermal shutdown, current limiting and safe-area control. With heat sinking, they can deliver over 1.5 amps of output current. These units feature internally trimmed output voltages to ±1% of nominal voltage. Standard voltages are -5V, -12V, -15V. These units are ideally suited for Military applications where a hermetically sealed package is required.
PART NUMBER DESIGNATOR
Standard Military Drawing Number Omnirel Part Number
5962-8874601 UX OM1905STM 5962-8874601 TX OM1905NTM 5962-8874701 UX OM1912STM 5962-8874701 TX OM1912NTM 5962-8874801 UX OM1915STM 5962-8874801 TX OM1915NTM
“U” = Isolated
“T” = Non-Isolated
3.3
4 11 R2 Supersedes 1 07 R1
3.3 - 93
OM1905STM/NTM - OM1915STM/NTM
ABSOLUTE MAXIMUM RATINGS @ 25°C
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -35 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . .- 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Typical Power/Thermal Charateristics:
Rated Power @ 25° C TC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15W
TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3W
Thermal Resistance q
aa qJA.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42°C/W
JC
q
JC
(Case U) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2°C/W
(Case T) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5°C/W
3.3
ELECTRICAL CHARACTERISTICS -5 Volt V
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
Line Regulation V
(Note 1) (Note 4) V
OUT
RLINE
TA= 25°C -4.95 -5.05 V
V
= -7.5V to -20V -4.85 -5.15 V
IN
I
= 5mA to 1.0, A, P < 15W
O
VIN= -7.5V to -20V 12 mV
= -8.0V to -12V 5 mV
IN
= -10V, Io= 500mA, -55°C TA 125°C (unless otherwise specified)
IN
25 mV
12 mV
Load Regulation V
(Note 1)
RLOAD
IO = 5mA to 1.5 Amp 20 mV
25 mV
I
= 250mA to 750 mA 15 mV
O
30 mV
Standby Current Drain I
SCD
3.0 mA
Standby Current Drain DI
Change With Line (Line)
Standby Current Drain DI
Change With Load (Load)
Dropout Voltage V Peak Output Current I Short Circuit Current I
(Note 2)
Ripple Rejection DV
Output Noise Voltage N
(Note 3) RMS
Long Term Stability DV
(Note 3) Dt
DV
SCD
SCD
DO
O (pk)
DS
IN
OUT
O
OUT
VIN= -7.0V to -20V 0.4 mA
IO= 5mA to 1000mA 0.4 mA
DV
= 100mV, I
OUT
TA= 25°C 1.5 3.3 A
VIN= -35V 1.2 A
= 1.0A 2.5 V
O
2.8 A
f =120 Hz, DVIN= -10V 63 dB
(Note 3) 60 dB
TA= 25°C, f =10 Hz to 100KHz 40 µV/V
TA= 25°C, t = 1000 hrs. 75 mV
2.5 mA
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN= -35V.
3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range.
3.3 - 94
.430 .410
.200 .190
.038 MAX.
.005
.120 TYP.
.537 .527
.665 .645
.420 .410
.150 .140
.750 .500
.100 TYP.
.035 .025
.045 .035
OM1905STM/NTM - OM1915NTM/STM
ELECTRICAL CHARACTERISTICS -12 Volt V
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
Line Regulation V
(Note 1) (Note 4) V
Load Regulation V
(Note 1)
Standby Current Drain I
Standby Current Drain DI
Change With Line (Line)
Standby Current Drain DI
Change With Load (Load)
Dropout Voltage V Peak Output Current I Short Circuit Current I
(Note 2)
Ripple Rejection DV
Output Noise Voltage N
(Note 3) RMS
Long Term Stability DV
(Note 3) Dt
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5 mA.
RLINE
RLOAD
SCD
O (pk)
DV
OUT
SCD
SCD
DO
DS
OUT
OUT
IN
O
TA= 25°C, f =10 Hz to 100KHz 40 µV/V
IN
TA= 25°C -11.88 -12.12 V
V
= -14.5V to -27V -11.64 -12.36 V
IN
I
= 5mA to 1.0 A, P < 15W
O
VIN= -14.5V to -27V 20 mV
= -16V to -22V 10 mV
IN
IO = 5mA to 1.5 Amp 32 mV
I
= 250mA to 750 mA 16 mV
O
VIN= -14.5V to -27V 0.8 mA
IO= 5mA to 1000mA 0.5 mA
DV
= 100mV, I
OUT
TA= 25°C, IO= 5mA to 1A 1.5 3.3 A
V
IN
f =120 Hz, DVIN= -10V 56 dB
(Note 3) 53 dB
TA= 25°C, t = 1000 hrs. 120 mV
= -35V.
MECHANICAL OUTLINE
= -19V, Io= 500mA, -55°C TA 125°C (unless otherwise specified)
IN
50 mV
30 mV
60 mV
30 mV
3.5 mA
4.0 mA
= 1.0A 1.8 V
O
= -35V 1.2 A
2.8 A
CONNECTION DIAGRAM
Case U
1 Ground 2 Input 3 Output 4 No Connection
3.3 - 95
3.3
4
Case T
1 Ground 2 Input 3 Output 4 Input
123
205 Crawford Street, Leominster, MA 01453 USA (508) 534-5776 FAX (508) 537-4246205 Crawford Street, Leominster, MA 01453 USA (508) 534-5776 FAX (508) 537-4246
OM1905STM/NTM - OM1915STM/NTM
ELECTRICAL CHARACTERISTICS -15 Volt V
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
Line Regulation V
(Note 1) (Note 4) V
Load Regulation V
(Note 1)
Standby Current Drain I
Standby Current Drain DI
Change With Line (Line)
Standby Current Drain DI
Change With Load (Load)
Dropout Voltage V Peak Output Current I Short Circuit Current I
(Note 2)
Ripple Rejection DV
Output Noise Voltage N
(Note 3) RMS
Long Term Stability DV
(Note 3) Dt
RLINE
RLOAD
O (pk)
DV
OUT
SCD
SCD
SCD
DO
DS
IN
OUT
O
OUT
= -23V, Io= 500mA, -55°C TA 125°C (unless otherwise specified)
IN
TA= 25°C -14.85 -15.15 V
V
= -17.5V to -30V -14.55 -15.45 V
IN
I
= 5mA to 1.0 A, P < 15 W
O
VIN= -17.5V to -30V 25 mV
50 mV
= -20V to -26V 15 mV
IN
25 mV
IO = 5mA to 1.5 Amp 35 mV
75 mV
I
= 250mA to 750 mA 21 mV
O
45 mV
6.0 mA
6.5 mA
VIN= -17.5V to -30V 0.8 mA
IO= 5mA to 1000 mA 0.5 mA
DV
OUT
= 100mV, I
= 1.0A 2.5 V
O
TA= 25°C 1.5 3.3 A
VIN= -35V 1.2 A
2.8 A
f =120 Hz, DVIN= -10V 53 dB
(Note 3) 50 dB
TA= 25°C, f =10 Hz to 100KHz 40 µV/V
TA= 25°C, t = 1000 hrs. 150 mV
3.3
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
= -35V.
IN
3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range.
TYPICAL PERFORMANCE CHARACTERISTICS
PEAK OUTPUT
3.5
3
2.5
2
1.5
1
Output Current (A)
0.5
DV
OUT
0
0 5 10 15 20 25 30 35
Input To Output Differential (V)
Tj= 25°C
Tj= 150°C
= 100mV
Tj= -55°C
DROPOUT VOLTAGE
2.5
2
1.5
1
Output Current (A)
0.5
DV
OUT
0
-75-50 -25 0 25 50 75 100 125 150
Junction Temperature (°C)
= 100MV
I
= 1A
OUT
I
= 0A
OUT
I
OUT
= 500mA
RIPPLE REJECTION
100
80
60
40
Ripple Rejection (dB)
20
0
V
- V = 8V
IN
10 100 1k 10k 100k
Frequency (Hz)
DC
I
= 1A
OUT
Tj= 25°C
+3.5V
V
= 5V
OUT
rms
Loading...