OMNIREL OM1905NKM, OM1915NKM, OM1912NKM Datasheet

3.3 - 87
3.3
Three T erminal, Fixed V oltage, 1.5 Amp Precision Negative Regulators In Hermetic JEDEC TO-3 P ackage
4 11 R0
HERMETIC TO-3 FIXED VOLTAGE NEGATIVE REGULATORS APPROVED TO DESC DRAWINGS
• Output Voltages: -5V, -12V, -15V
• Output Voltages Set Internally to ±1%
• Built-In Thermal Overload Protection
• Short Circuit Current Limiting
• Similar To Industry Standards 7905, 7912, 7915
• Hi-Rel Screening Available
DESCRIPTION
These three terminal negative regulators are supplied in a hermetically sealed TO-3 metal package . All protective features are designed into the circuit, including thermal shutdown, current limiting and safe-area control. With heat sinking, they can deliver over 1.5 amps of output current. These units feature internally trimmed output voltages to ±1% of nominal voltage. Standard voltages are -5V, -12V, -15V. These units are ideally suited for Military applications where a hermetically sealed package is required.
PART NUMBER DESIGNATOR
Standard Military Drawing Number Omnirel Part Number
5962-8874601 YX OM1905NKM 5962-8874701 YX OM1912NKM 5962-8874801 YX OM1915NKM
OM1915NKMOM1905NKM
OM1912NKM
3.3 - 88
OM1905NKM - OM1915NKM
3.3
ELECTRICAL CHARACTERISTICS -5 Volt V
IN
= -10V, Io= 500mA, -55°C TA 125°C (unless otherwise specified)
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
OUT
TA= 25°C -4.95 -5.05 V
V
IN
= -7.5V to -20V -4.85 -5.15 V
I
O
= 5mA to 1.0 A, P< 20W
Line Regulation V
RLINE
VIN= -7.5V to -20V 12 mV
(Note 1)
25 mV
(Note 4) V
IN
= -8.0V to -12V 5 mV
12 mV
Load Regulation V
RLOAD
IO = 5mA to 1.5 Amp 20 mV
(Note 1)
25 mV
I
O
= 250mA to 750 mA 15 mV
30 mV
Standby Current Drain I
SCD
2.5 mA
3.0 mA
Standby Current Drain DI
SCD
VIN= -7.0V to -20V 0.4 mA
Change With Line (Line)
Standby Current Drain DI
SCD
IO= 5mA to 1000mA 0.4 mA
Change With Load (Load)
Dropout Voltage V
DO
DV
OUT
= 100mV, I
O
= 1.0A 2.5 V
Peak Output Current I
O (pk)
TA= 25°C 1.5 3.3 A
Short Circuit Current I
DS
VIN= -35V 1.2 A
(Note 2)
2.8 A
Ripple Rejection DV
IN
f =120 Hz, DVIN= -10V 63 dB
DV
OUT
(Note 3) 60 dB
Output Noise Voltage N
O
TA= 25°C, f =10 Hz to 100KHz 40 µV/V
(Note 3) RMS
Long Term Stability DV
OUT
TA= 25°C, t = 1000 hrs. 75 mV
(Note 3) Dt
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN= -35V.
3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range.
ABSOLUTE MAXIMUM RATINGS @ 25°C
Input Voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -35 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . .- 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Typical Power/Thermal Charateristics:
Rated Power @ 25° C TC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20W
TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.6W
Thermal Resistance q
JC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2°C/W
aa qJA.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42°C/W