OM1830SCM
OM1830NCM
7.5 AMP LOW DROPOUT POSITIVE ADJUSTABLE
REGULATOR APPROVED TO DESC DRAWING 5962-89520
Three T erminal, Positive Adjustable
Low Dropout Voltage Regulator In
Hermetic JEDEC TO-258AA Package
FEATURES
• Similar To Industry Standard LT1083
• Approved To DESC Standardized Military Drawing Number 5962-8952001Y
• Adjustable Output Voltage
• Built In Thermal Overload Protection
• Short Circuit Current Limiting
• Available In Isolated Package
• Maximum Output Voltage Tolerance is Guaranteed To ±1%
• Guaranteed Dropout Voltage At Multiple Current Levels
• Product Also Available in Non-Isolated Package
DESCRIPTION
This three terminal positive adjustable voltage regulator is designed to provide 7.5A
with higher efficiency than conventional voltage regulators. This device is designed
to operate down to 1 volt input to output differential and the dropout voltage is fully
specified as a function of load current. Supplied in easy-to-use hermetic TO-258
package, this device is ideally suited for Military applications where small size and
high reliability is required.
ABSOLUTE MAXIMUM RATINGS @ 25°C
Power Dissipation (Pd) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Internally Limited
Input - Output Voltage Differential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . - 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Lead Temperature (Soldering 10 seconds) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300°C
Thermal Resistance:
qJC(Isolated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.75°C/W
qJC(Non-Isolated) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.3°C/W
Maximum Output Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.5 A
3.3
4 11 R1
Supersedes 1 06 R0
3.3 - 69
OM1830SCM OM1830NCM
ELECTRICAL CHARACTERISTICS -55°C T
+125°C (unless otherwise specified)
A
Parameter Symbol Test Conditions Min. Max. Unit
Reference Voltage V
Line Regulation ³V
(Note 1) ³V
Load Regulation ³V
(Note 1) ³I
REF
OUT
IN
OUT
OUT
VIN- V
I
= 10 mA, TA= 25° C
OUT
1.5 V V
10 mA I
1.5 V VIN- V
I
= 10 mA, TA= 25° C
OUT
15 V V
I
OUT
VIN- V
OUT
10 mA I
Œ= 3.0 V, 1.238 1.262 V
OUT
- V
Œ 25 V, • 1.225 1.270 V
IN
OUT
5.0 A
OUT
Œ 15 V, 0.2 %
OUT
- V
Œ 35 V, • 0.5 %
IN
OUT
= 10 mA
Œ= 3.0 V, TA= 25° C 0.3 %
5.0 A
OUT
• 0.4 %
Dropout Voltage V
DO
Thermal Regulation - 30 ms pulse, T
Ripple Rejection ³V
Adjust Pin Current I
Adjust Pin Current Change ³I
Miminum Load Current I
Current Limit I
Temperature Stability ³V
IN
³V
OUT
Adj
Adj
Min
Lim
OUT
(Note 2) ³T
Long Term Stability ³V
OUT
(Note 2) ³T
I
= IFL, IFL= 5.0 A, ³V
OUT
f = 120 Hz, C
C
= 25 µF (tantalum), IFL= 5.0 A,
OUT
V
- V
Œ= 3.0 V, I
IN
OUT
1.5 V VIN- V
10 mA I
OUT
1.5 V VIN- V
10 mA I
OUT
VIN- V
OUT
VIN- V
OUT
V
- V
IN
OUT
= 1% • 1.5 V
REF
= +25° C 0.01 %/W
A
= 25 µF, • 60 dB
Adj
= I
OUT
FL
Œ 25 V • 120 µA
OUT
5.0 A
Œ 25 V • 5.0 µA
OUT
5.0 A
Œ= 25 V • 10 mA
Œ= 5.0 V • 8.0 A
Œ= 25 V • 0.4 A
-55° C TJ +125° C • 1.5 %
TA= +125° C, t = 1000 hrs 1.0 %
3.3
Notes:
1. Line and Load Regulation are measured at a constant junction temperature using a low duty cycle pulse technique.
Although power dissipation is internally limited, regulation is guaranteed up to the maximum power dissipation of 60 W.
Power dissipation is determined by the input/output differential voltage and the output current. Guaranteed maximum
power dissipation will not be available over the full input/output voltage range.
2. Guaranteed by design, characterization or correlation to other tested parameters.
3. The • denotes the specifications which apply over the full operating temperature range.
PART NUMBER DESIGNATOR
Standard Military Drawing Number Omnirel Part Number
8952001Y OM1830SCM
8952001Z OM1830NCM
“Y” = Isolated
3.3 - 70