OMNIREL OM1815STM, OM1815NTM, OM1812STM, OM1805NTM, OM1812NTM Datasheet

...
OM1805STM OM1805NTM
OM1812STM OM1812NTM
ISOLATED HERMETIC TO-257AA FIXED VOLTAGE REGULATORS APPROVED TO DESC DRAWINGS
Three T erminal, Fixed V oltage, 1.5 Amp Precision Positive Regulators In Hermetic JEDEC TO-257AA P ackage
FEATURES
• Isolated Hermetic Package, JEDEC TO-257AA Outline
• Output Voltages: 5V, 12V, 15V
• Output Voltages Set Internally to ±1%
• Built-In Thermal Overload Protection
• Short Circuit Current Limiting
• Product Is Also Available In Non-Isolated Package
• Similar To Industry Standards 7805, 7812, 7815
OM1815STM OM1815NTM
DESCRIPTION
These three terminal positive regulators are supplied in a hermetically sealed metal package whose outline is similar to the industry standard TO-220 plastic package. All protective features are designed into the circuit, including thermal shutdown, current limiting and safe-area control. With heat sinking, they can deliver over
1.5 amps of output current. These units feature internally trimmed output voltages ±1% of nominal voltage. These units are ideally suited for Military applications where a hermetically sealed package is required.
PART NUMBER DESIGNATOR
Standard Military Drawing Number Omnirel Part Number
5962-8778201 UX OM1805STM 5962-8778201 TX OM1805NTM 5962-8777601 UX OM1812STM 5962-8777601 TX OM1812NTM 5962-8855301 UX OM1815STM 5962-8855301 TX OM1815NTM
“U” = Isolated
“T” = Non-Isolated
3.3
4 11 R2 Supersedes 1 07 R1
3.3 - 57
OM1805STM/NTM - OM1815STM/NTM
ABSOLUTE MAXIMUM RATINGS @ 25°C
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +35 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . - 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Typical Power/Thermal Charateristics:
Rated Power @ 25° C TC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15W
TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3W
Thermal Resistance q
a
JC
qJCCase T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5°C/W
qJACase T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42°C/W
Case U. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2°C/W
3.3
ELECTRICAL CHARACTERISTICS 5 Volt V
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
Line Regulation V
(Note 1) (Note 4) V
OUT
RLINE
V
IN
I
= 5mA to 1.0 A, P < 15W
O
VIN= 7.5V to 20V 5 mV
IN
= 10V, Io= 500mA, -55°C TA 125°C (unless otherwise specified)
IN
TA= 25°C 4.92 5.08 V = 7.5V to 20V 4.85 5.15 V
12 mV
= 8.0V to 12V 4 mV
10 mV
Load Regulation V
(Note 1) I
RLOAD
IO = 5mA to 1.5 Amp 12 mV
= 5mA to 1.0 Amp 25 mV
O
I
= 250mA to 750 mA 6 mV
O
15 mV
Standby Current Drain I
SCD
6.5 mA
Standby Current Drain DI
Change With Line (Line)
Standby Current Drain DI
Change With Load (Load)
Dropout Voltage V Peak Output Current I Short Circuit Current I
(Note 2)
Ripple Rejection DV
Output Noise Voltage N
(Note 3) RMS
Long Term Stability DV
(Note 3) Dt
DV
SCD
SCD
DO
O (pk)
DS
IN
OUT
O
OUT
V
= 7.5V to 20V 0.8 mA
IN
IO= 5mA to 1000mA 0.5 mA
TA= 25°C, DV
= 100mV, I
OUT
TA= 25°C 1.5 3.3 A VIN= 35V 1.2 A
= 1.0A 2.5 V
O
2.8 A
f =120 Hz, DVIN= 10V 68 dB
(Note 3) 60 dB
TA= 25°C, f =10 Hz to 100KHz 40 µV/V
TA= 25°C, t = 1000 hrs. 75 mV
6mA
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN= 35V.
3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
3.3 - 58