OMNIREL OM1812NMM, OM1805NMM, OM1815NMM Datasheet

3.5 - 37
3.5
Three Terminal, Fixed Voltage, 1.5 Amp
Precision Positive Regulators In Hermetic
Surface Mount Package
HERMETIC SURF ACE MOUNT FIXED VOLTAGE POSITIVE
REGULATORS APPROVED TO DESC DRA WINGS
Hermetic Surface Mount Package
Output Voltages: +5V, +12V, +15V
Output Voltages Set Internally To ±1%
Built-In Thermal Overload Protection
Short Circuit Current Limiting
Hi-Rel Screening Available
DESCRIPTION
These three terminal positive regulators are supplied in a hermetically sealed surface
mount package. All protective features are designed into the circuit including thermal
shutdown, current limiting and safe-area control. With heat sinking, they can deliver
over 1.5 amps of output current. These units feature internally trimmed output
voltages to ±1% of nominal voltage. Standard voltages are +5V, +12V, and +15V.
These units are ideally suited for Military applications where a hermetic surface
mount package is required.
PART NUMBER DESIGNATOR
Standard Military Drawing Number Omnirel Part Number
5962-8778201 NX OM1805NMM
5962-8777601 NX OM1812NMM
5962-8855301 NX OM1815NMM
4 11 R0
OM1815NMMOM1805NMM
OM1812NMM
3.5 - 38
3.5
OM1805NMM - OM1815NMM
ELECTRICAL CHARACTERISTICS 5 Volt
V
IN
= 10V, I
o
= 500mA, -55°C ≤ T
A
125°C (unless otherwise specified)
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
OUT
T
A
= 25°C 4.92 5.08 V
V
IN
= 7.5V to 20V 4.85 5.15 V
I
O
= 5mA to 1.0A, P < 15 W
Line Regulation V
RLINE
V
IN
= 7.5V to 20V 5 mV
(Note 1)
12 mV
(Note 4) V
IN
= 8.0V to 12V 4 mV
10 mV
Load Regulation V
RLOAD
I
O
= 5mA to 1.5 Amp 12 mV
(Note 1) I
O
= 5mA to 1.0Amp 25 mV
I
O
= 250mA to 750 mA 6 mV
15 mV
Standby Current Drain I
SCD
6mA
6.5 mA
Standby Current Drain I
SCD
V
IN
= 7.5V to 20V 0.8 mA
Change With Line (Line)
Standby Current Drain I
SCD
I
O
= 5mA to 1000mA 0.5 mA
Change With Load (Load)
Dropout Voltage V
DO
T
A
= 25°C, V
OUT
= 100mV, I
O
=1.0A 2.5 V
Peak Output Current I
O (pk)
T
A
= 25°C 1.5 3.3 A
Short Circuit Current I
DS
V
IN
= 35V 1.2 A
(Note 2)
2.8 A
Ripple Rejection V
IN
f =120 Hz, V
IN
= 10V 68 dB
V
OUT
(Note 3) 60 dB
Output Noise Voltage N
O
T
A
= 25°C, f =10 Hz to 100KHz 40 µV/V
(Note 3) RMS
Long Term Stability V
OUT
T
A
= 25°C, t = 1000 hrs. 75 mV
(Note 3) t
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used.
Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to V
IN
= 35V.
3. If not tested, shall be guaranteed to the specified limits.
The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
ABSOLUTE MAXIMUM RATINGS @ 25°C
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +35 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . - 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Typical Power/Thermal Charateristics:
Rated Power @ 25° C T
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15W
T
A
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3W
Thermal Resistance θ
JC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.5°C/W
θ
JA
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120°C/W