OMNIREL OM1805NKM, OM1815NKM, OM1812NKM Datasheet

OM1812NKM
HERMETIC TO-3 FIXED VOLTAGE REGULATORS APPROVED TO DESC DRAWINGS
Three T erminal, Fixed V oltage, 1.5 Amp Precision Positive Regulators In Hermetic JEDEC TO-3 P ackage
• Output Voltages: 5V, 12V, 15V
• Output Voltages Set Internally to ±1%
• Built-In Thermal Overload Protection
• Short Circuit Current Limiting
• Similar To Industry Standards 7805, 7812, 7815
• Hi-Rel Screening Available
OM1815NKMOM1805NKM
DESCRIPTION
These three terminal positive regulators are supplied in a hermetically sealed metal TO-3 package. All protective features are designed into the circuit, including thermal shutdown, current limiting and safe-area control. With heat sinking, they can deliver over 1.5 amps of output current. These units feature internally trimmed output voltages ±1% of nominal voltage. These units are ideally suited for Military applications where a hermetically sealed package is required.
PART NUMBER DESIGNATOR
Standard Military Drawing Number Omnirel Part Number
5962-8778201 YX OM1805NKM 5962-8777601 YX OM1812NKM 5962-8855301 YX OM1815NKM
3.3
4 11 R0
3.3 - 51
OM1805NKM - OM1815NKM
ABSOLUTE MAXIMUM RATINGS @ 25°C
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +35 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . - 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Typical Power/Thermal Charateristics:
Rated Power @ 25° C TC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20W
Thermal Resistance qJC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3°C/W
a
TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3W
qJA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29°C/W
3.3
ELECTRICAL CHARACTERISTICS 5 Volt V
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
Line Regulation V
(Note 1) (Note 4) V
OUT
RLINE
V
IN
I
= 5mA to 1.0A, P < 20 W
O
VIN= 7.5V to 20V 5 mV
IN
= 10V, Io= 500mA, -55°C TA 125°C (unless otherwise specified)
IN
TA= 25°C 4.92 5.08 V = 7.5V to 20V 4.85 5.15 V
12 mV
= 8.0V to 12V 4 mV
10 mV
Load Regulation V
(Note 1) I
RLOAD
IO = 5mA to 1.5 Amp 12 mV
= 5mA to 1.0Amp 25 mV
O
I
= 250mA to 750 mA 6 mV
O
15 mV
Standby Current Drain I
SCD
6.5 mA
Standby Current Drain DI
Change With Line (Line)
Standby Current Drain DI
Change With Load (Load)
Dropout Voltage V Peak Output Current I Short Circuit Current I
(Note 2)
Ripple Rejection DV
Output Noise Voltage N
(Note 3) RMS
Long Term Stability DV
(Note 3) Dt
DV
SCD
SCD
DO
O (pk)
DS
IN
OUT
O
OUT
V
= 7.5V to 20V 0.8 mA
IN
IO= 5mA to 1000mA 0.5 mA
TA= 25°C, DV
= 100mV, I
OUT
TA= 25°C 1.5 3.3 A VIN= 35V 1.2 A
= 1.0A 2.5 V
O
2.8 A
f =120 Hz, DVIN= 10V 66 dB
(Note 3) 60 dB
TA= 25°C, f =10 Hz to 100KHz 40 µV/V
TA= 25°C, t = 1000 hrs. 75 mV
6mA
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN= 35V.
3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
3.3 - 52
OM1805NKM - OM1815NKM
1.197
1.177
0.675
0.655
0.188 R. MAX.
0.440
0.420
0.161
0.151
0.525 R. MAX.
0.225
0.205
SEATING
PLANE
0.312 MIN.
0.450
0.250
0.043
0.038
2 PLCS.
0.135 MAX.
0.875 MAX.
1.53
REF.
ELECTRICAL CHARACTERISTICS 12 Volt V
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
Line Regulation V
(Note 1) (Note 4) V
OUT
RLINE
TA= 25°C 11.88 12.12 V
V
= 14.5V to 27V 11.64 12.36 V
IN
I
= 5mA to 1.0 A, P < 20W
O
VIN= 14.5V to 27V 18 mV
= 16V to 22V 9 mV
IN
= 19V, Io= 500mA, -55°C TA 125°C (unless otherwise specified)
IN
50 mV
30 mV
Load Regulation V
(Note 1) I
RLOAD
IO = 5mA to 1.5 Amp 32 mV
= 5mA to 1.0 Amp 60 mV
O
I
= 250mA to 750 mA 20 mV
O
40 mV
Standby Current Drain I
SCD
6.5 mA
Standby Current Drain DI
Change With Line (Line)
Standby Current Drain DI
Change With Load (Load)
Dropout Voltage V Peak Output Current I Short Circuit Current I
(Note 2)
Ripple Rejection DV
Output Noise Voltage N
(Note 3) RMS
Long Term Stability DV
(Note 3) Dt
DV
SCD
SCD
DO
O (pk)
DS
IN
OUT
O
OUT
V
= 15V to 30V 0.8 mA
IN
IO= 5mA to 1000mA 0.5 mA
DV
= 100mV, I
OUT
TA= 25°C 1.5 3.3 A VIN= 35V 1.2 A
= 1.0A 2.5 V
O
2.8 A
f =120 Hz, DVIN= 10V 61 dB
(Note 3) 54 dB
TA= 25°C, f =10 Hz to 100KHz 40 µV/V
TA= 25°C, t = 1000 hrs. 120 mV
6.0 mA
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN= 35V.
3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
MECHANICAL OUTLINE
Pin Connection
Pin 1: Input Pin 2: Output Case: Ground
3.3 - 53
2 1
3.3
OM1805NKM - OM1815NKM
205 Crawford Street, Leominster, MA 01453 USA (508) 534-5776 FAX (508) 537-4246
ELECTRICAL CHARACTERISTICS 15 Volt V
= 23V, Io= 500mA, -55°C TA 125°C (unless otherwise specified)
IN
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
Line Regulation V
OUT
RLINE
(Note 1) (Note 4) V
TA= 25°C 14.8 15.2 V
V
= 18.5V to 30V 14.6 15.4 V
IN
I
= 5mA to 1.0 A, P < 20W
O
VIN= 17.5V to 30V 20 mV
50 mV
= 20V to 26V 15 mV
IN
25 mV
Load Regulation V
RLOAD
(Note 1) I
IO = 5mA to 1.5 Amp 35 mV
= 5mA to 1.0 Amp 75 mV
O
I
= 250mA to 750 mA 21 mV
O
45 mV
Standby Current Drain I
SCD
6.5 mA
Standby Current Drain DI
SCD
Change With Line (Line)
Standby Current Drain DI
SCD
Change With Load (Load)
Dropout Voltage V Peak Output Current I Short Circuit Current I
DO
O (pk)
DS
(Note 2)
Ripple Rejection DV
Output Noise Voltage N
DV
IN
OUT
O
(Note 3) RMS
Long Term Stability DV
OUT
(Note 3) Dt
V
= 18.5V to 30V 0.8 mA
IN
IO= 5mA to 1000mA 0.5 mA
TA= 25°C, DV
OUT
= 100mV, I
= 1.0A 2.5 V
O
TA= 25°C 1.5 3.3 A VIN= 35V 1.2 A
2.8 A
f =120 Hz, DVIN= 10V 54 dB
(Note 3) 52 dB
TA= 25°C, f =10 Hz to 100KHz 40 µV/V
TA= 25°C, t = 1000 hrs. 150 mV
6.0 mA
3.3
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN= 35V.
3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
TYPICAL PERFORMANCE CHARACTERISTICS
PEAK OUTPUT
3.5
3
2.5
2
1.5
1
Output Current (A)
0.5
DV
OUT
0
0 5 10 15 20 25 30 35
Input To Output Differential (V)
Tj= 25°C
Tj= 150°C
= 100mV
Tj= -55°C
DROPOUT VOLTAGE
2.5
2
1.5
1
0.5
DV
0
-75-50 -25 0 25 50 75 100 125 150
Junction Temperature (°C)
OUT
= 100MV
I
= 1A
OUT
I
= 500mA
OUT
I
= 0A
OUT
RIPPLE REJECTION
100
80
60
40
Ripple Rejection (dB)
20
0
V
- V = 8V
IN
10 100 1k 10k 100k
Frequency (Hz)
I
T
OUT
= 25°C
j
DC
= 1A
+3.5V
V
OUT
rms
= 5V