OMNIREL OM1815N5M, OM1812N5M, OM1805N5M Datasheet

3.5 - 33
3.5
LCC 20 Fixed Voltage, Precision Positive Regulators In Hermetic Surface Mount Package
HERMETIC SURF ACE MOUNT FIXED VOLTAGE POSITIVE REGULATORS APPROVED TO DESC DRA WINGS
• Hermetic Surface Mount Package
• Output Voltages: +5V, +12V, +15V
• Output Voltages Set Internally To ±1%
• Built-In Thermal Overload Protection
• Short Circuit Current Limiting
• Hi-Rel Screening Available
DESCRIPTION
These positive regulators are supplied in a hermetically sealed surface mount package. All protective features are designed into the circuit including thermal shutdown, current limiting and safe-area control. With heat sinking, they can deliver over .5 amps of output current. These units feature internally trimmed output voltages to ±1% of nominal voltage. Standard voltages are +5V, +12V, and +15V. These units are ideally suited for Military applications where a hermetic surface mount package is required.
PART NUMBER DESIGNATOR
Standard Military Drawing Number Omnirel Part Number
5962-8778201 2X OM1805N2M 5962-8777601 2X OM1812N2M 5962-8855301 2X OM1815N2M
4 11 R0
OM1815N2MOM1805N2M
OM1812N2M
3.5 - 34
3.5
OM1805N2M - OM1815N2M
ELECTRICAL CHARACTERISTICS 5 Volt
VIN= 10V, Io= 100mA, -55°C ≤ TA≤ 125°C (unless otherwise specified)
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
OUT
TA= 25°C 4.92 5.08 V
V
IN
= 7.5V to 20V 4.85 5.15 V
I
O
= 5mA to 500 mA, P < 2 W
Line Regulation V
RLINE
VIN= 7.5V to 20V 5 mV
(Note 1)
12mV
(Note 4) V
IN
= 8.0V to 12V 4 mV
10mV
Load Regulation V
RLOAD
IO = 5mA to 500 mA 25 mV
(Note 1)
50 mV
Standby Current Drain I
SCD
6mA
6.5 mA
Standby Current Drain ∆I
SCD
V
IN
= 7.5V to 20V 0.8 mA
Change With Line (Line)
Standby Current Drain ∆I
SCD
IO= 5mA to 500mA 0.5 mA
Change With Load (Load)
Dropout Voltage V
DO
TA= 25°C, ∆V
OUT
= 100mV, I
O
=500mA 2.5 V
Peak Output Current I
O (pk)
TA= 25°C 0.5 1.7 A
Short Circuit Current I
DS
VIN= 35V 0.7 A
(Note 2)
2.0 A
Ripple Rejection ∆V
IN
f =120 Hz, ∆VIN= 10V 68 dB
V
OUT
(Note 3) 60 dB
Output Noise Voltage N
O
TA= 25°C, f =10 Hz to 100KHz 40 µV/V
(Note 3) RMS
Long Term Stability ∆V
OUT
TA= 25°C, t = 1000 hrs. 75 mV
(Note 3) ∆t
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN= 35V.
3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
ABSOLUTE MAXIMUM RATINGS @ 25°C
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +35 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . - 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Typical Power/Thermal Charateristics:
Rated Power @ 25° C T
C
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 W
TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1040 mW
Thermal Resistance θJC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20°C/W
θJA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120°C/W
a
3.5 - 35
3.5
OM1805N2M - OM1815N2M
ELECTRICAL CHARACTERISTICS 12 Volt V
IN
= 19V, Io= 100mA, -55°C ≤ TA≤ 125°C (unless otherwise specified)
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
OUT
TA= 25°C 11.88 12.12 V
V
IN
= 14.5V to 27V 11.64 12.36 V
I
O
= 5mA to 500 mA, P < 2W
Line Regulation V
RLINE
VIN= 14.5V to 27V 18 mV
(Note 1)
50 mV
(Note 4) V
IN
= 16V to 22V 9 mV
30 mV
Load Regulation V
RLOAD
IO = 5mA to 500mA 30 mV
(Note 1)
60 mV
Standby Current Drain I
SCD
6.0 mA
6.5 mA
Standby Current Drain ∆I
SCD
V
IN
= 15V to 30V 0.8 mA
Change With Line (Line)
Standby Current Drain ∆I
SCD
IO= 5mA to 500mA 0.5 mA
Change With Load (Load)
Dropout Voltage V
DO
V
OUT
= 100mV, I
O
=500mA 2.5 V
Peak Output Current I
O (pk)
TA= 25°C 0.5 1.7 A
Short Circuit Current I
DS
VIN= 35V 0.7 A
(Note 2)
2.0 A
Ripple Rejection ∆V
IN
f =120 Hz, ∆VIN= 10V 61 dB
V
OUT
(Note 3) 54 dB
Output Noise Voltage N
O
TA= 25°C, f =10 Hz to 100KHz 40 µV/V
(Note 3) RMS
Long Term Stability ∆V
OUT
TA= 25°C, t = 1000 hrs. 120 mV
(Note 3) ∆t
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN= 35V.
3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.
.075 (±.010) TYP.
.040.020 X45°
REF.
.040 X45°
REF (3 PL)
.010
.160 SQ. REF.
.065
.009 R. 20 PLCS.
3
1
19
18
14
4
13
9
.003
.050
TYP.
.050
(±.005)
TYP.
.085
.025 SQ.
TYP.
(±.003)
.025
TYP.
MECHANICAL OUTLINE
Terminal Number
1 NC 2V
IN
3NC 4NC 5NC 6NC 7 GND 8NC 9NC
10V
OUT
11 NC 12V
OUT
13NC 14NC 15V
OUT
SENSE 16NC 17V
IN
18NC 19NC 20 NC
NOTE: For normal operation, V
OUT
must be connected externally
to load.
3.5
OM1805N2M - OM1815N2M
ELECTRICAL CHARACTERISTICS 15 Volt V
IN
= 23V, Io= 100mA, -55°C ≤ TA≤ 125°C (unless otherwise specified)
Parameter Symbol Test Conditions Min. Max. Unit
Output Voltage V
OUT
TA= 25°C 14.8 15.2 V
V
IN
= 18.5V to 30V 14.6 15.4 V
I
O
= 5mA to 500 mA, P < 2W
Line Regulation V
RLINE
VIN= 17.5V to 30V 20 mV
(Note 1)
50 mV
(Note 4) V
IN
= 20V to 26V 15 mV
25 mV
Load Regulation V
RLOAD
IO = 5mA to 500 mA 50 mV
(Note 1)
90 mV
Standby Current Drain I
SCD
6.0 mA
6.5 mA
Standby Current Drain ∆I
SCD
V
IN
= 18.5V to 30V 0.8 mA
Change With Line (Line)
Standby Current Drain ∆I
SCD
IO= 5mA to 500mA 0.5 mA
Change With Load (Load)
Dropout Voltage V
DO
TA= 25°C, ∆V
OUT
= 100mV, I
O
=500mA 2.5 V
Peak Output Current I
O (pk)
TA= 25°C 0.5 1.7 A
Short Circuit Current I
DS
VIN= 35V 0.7 A
(Note 2)
2.0 A
Ripple Rejection ∆V
IN
f =120 Hz, ∆VIN= 10V 54 dB
V
OUT
(Note 3) 52 dB
Output Noise Voltage N
O
TA= 25°C, f =10 Hz to 100KHz 40 µV/V
(Note 3) RMS
Long Term Stability ∆V
OUT
TA= 25°C, t = 1000 hrs. 150 mV
(Note 3) ∆t
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately.
2. Short Circuit protection is only assured up to VIN= 35V.
3. If not tested, shall be guaranteed to the specified limits. The • denotes the specifications which apply over the full operating temperature range.
4. Minimum load current for full line regulation = 5.0 mA.