OMNIREL OM1320NKM, OM1320STM, OM1320N2M, OM1320NMM, OM1320MM Datasheet

3.5 - 1
3.5
Three Terminal, Precision Adjustable Positive Voltage Regulator In Hermetic Style Packages (LM117)
4 11 R2 Supersedes 1 07 R1
OM1320STM OM1320N2M
OM1320NMM
OM1320NTM
OM1320SMM OM1320NKM
FEATURES
• Similar To Industry Standard LM117
• Approved To DESC Standardized Military Drawing Number 7703401
• Built In Thermal Overload Protection
• Short Circuit Current Limiting
• Available In Six Package Styles
DESCRIPTION
These three terminal positive regulators are supplied in hermetically sealed packages. All protective features are designed into the circuit, including thermal shutdown, current-limiting, and safe-area control. With heat sinking, these devices can deliver up to 1.5 amps of output current. The LCC-20 device is limited to .5 amps. The unit also features output voltages that can be fixed from 1.2 volts to 37 volts using external resistors.
ABSOLUTE MAXIMUM RATINGS T
c
@ 25°C
Power Dissipation
Case 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.1 W
Case-All Others. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 W
Input - Output Voltage Differential . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 V
Operating Junction Temperature Range . . . . . . . . . . . . . . . . . . . . . - 55°C to + 150°C
Storage Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65°C to + 150°C
Lead Temperature (Soldering 10 seconds) . . . . . . . . . . . . . . . . . . . . . . . . . . . 300°C
Thermal Resistance, Junction to Case:
Case 2, LCC-20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17°C/W
Case U & M, TO-257 (Isol) and SMD-3 . . . . . . . . . . . . . . . . . . . . . . . . . . 4.2°C/W
Case T&N, TO-257 (Non-Isol) and SMD-1 . . . . . . . . . . . . . . . . . . . . . . . 3.5°C/W
Case Y, TO-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.0°C/W
Maximum Output Current:
Case 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 A
Case-All Others. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5 A
Recommended Operating Conditions:
Output Voltage Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.2 to 37 VDC
Ambient Operating Temperature Range (TA). . . . . . . . . . . . . . . . - 55°C to + 125°C
Input Voltage Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.25 to 41.25 VDC
Please see mechanical
outlines herein
3.5 - 2
3.5
OM1320NTM, OM1320STM, OM1320NKM, OM1320SMM, OM1320NMM, OM1320N2M
ELECTRICAL CHARACTERISTICS -55°C ≤ TA≤ 125°C, IL= 8mA (unless otherwise specified) OM1320NTM, OM1320STM, OM1320NKM, OM1320SMM, OM1320NMM
Parameter Symbol Test Conditions Min. Max. Unit
Reference Voltage V
REF
V
DIFF
= 3.0V, TA= 25°C 1.20 1.30 V
DIFF
= 3.3V 1.20 1.30 V
V
DIFF
= 40V 1.20 1.30
Line Regulation R
LINE
3.0V ≤ V
DIFF
≤ 40V, V
out
= V
ref
, TA= 25°C -9 9 mV
(Note 1) 3.3V ≤ V
DIFF
≤ 40V, V
out
= V
ref
-23 23
Load Regulation R
LOADVDIFF
= 3.0V, 10mA ≤ IL≤ 1.5A, TA= 25°C -15 15
(Note 1) V
DIFF
= 3.3V, 10mA ≤ IL≤ 1.5A -15 15 mV
V
DIFF
= 40V, 10mA ≤ IL≤ 300mA, TA= 25°C -15 15 V
DIFF
= 40V, 10mA ≤ IL≤ 195mA -15 15
Thermal Regulation V
RTH
Vin= 14.6V, IL= 1.5A -16 16 mV
P
d
= 20 Watts, t = 20 ms, TA=25°C
Ripple Rejection R
N
f = 120 Hz, V
out
= V
ref
66 dB
(Note 2) C
Adj
= 10 µF
Adjustment Pin Current I
Adj
V
DIFF
= 3.0V, TA= 25°C 100 V
DIFF
= 3.3V 100 µA
V
DIFF
= 40V 100
Adjustment Pin ∆I
Adj
V
DIFF
= 3.0V, 10mA ≤ IL≤ 1.5A, TA= 25°C -5 5
Current Change V
DIFF
= 3.3V, 10mA ≤ IL≤ 1.5A -5 5
V
DIFF
= 40V, 10mA ≤ IL≤ 300mA, TA= 25°C -5 5 V
DIFF
= 40V, 10mA ≤ IL≤ 195mA -5 5 µA
3.0V ≤ V
DIFF
≤ 40V, TA= 25°C -5 5
3.3V ≤ V
DIFF
≤ 40V -5 5
Miminum Load Current I
Lmin
V
DIFF
= 3.0V, V
OUT
= 1.4V (forced) 5.0
V
DIFF
= 3.3V, V
OUT
= 1.4V (forced) 5.0 mA
V
DIFF
= 40V, V
OUT
= 1.4V (forced) 5.0
Current Limit I
CL
V
DIFF
= 15V 1.5 3.5
(Note 2) V
DIFF
= 40V, TA= 25°C 0.18 1.5 A
Notes:
1. Load and Line Regulation are specified at a constant junction temperature. Pulse testing with low duty cycle is used. Changes in output voltage due to heating effects must be taken into account separately.
2. If not tested, shall be guaranteed to the specified limits.
3. The denotes the specifications which apply over the full operating temperature range.
PART NUMBER DESIGNATOR
Standard Military Drawing Number Omnirel Part Number Omnirel Package Designation
7703401M OM1320SMM SMD-3 7703401U OM1320STM TO-257 (Isolated)
7703401T OM1320NTM TO-257 (non-Isolated) 7703401Y OM1320 NKM TO-3
7703401N OM1320NMM SMD-1
77034012 OM1320N2M LCC-20