OmniPod DASH System Quick Start Manual

Page 1
QUICK START GUIDE
Page 2
2
WELCOME PODDER™!
+ If you are new to the Omnipod
DASH™ System, this guide will be helpful during your live-training with your Certified Pod Trainer.
+ If you are a current user of the Omnipod®
System, use the Omnipod DASH™ System User Guide, Quick Start Guide and online training module to get started. You can view the Omnipod DASH™ System online training module in your PodderCentral™ account.
BEFORE YOU DASH™ ON …
Please ensure you thoroughly review your Omnipod DASH™ System User Guide before
you attempt to start your device.
Personal Diabetes Manager (PDM) Kit
+ Take an inventory of your Personal
Diabetes Manager (PDM) Kit
+ Register your Omnipod DASH™ System at
PodderCentral™
If you have any questions about setting up your new Personal Diabetes Manager please contact Customer Care at 800-591-3455 (outside US 978-600-7850) for support 24 hours a day, 7 days a week.
If you have any questions about your individual pump therapy settings, please contact your healthcare provider.
PDM + Battery Black
PDM Skin
Carry Case User Guide
USER GUIDE
OMNIPOD DASH
TM
USER GUIDE
Podder’s handbook
TM
Charging Cable
& Adapter
Page 3
Here’s How to Access:
• Visit www.myomnipod.com/PodderCentral and create an account
• If you don’t have access to a computer, call Customer Care at 800-591-3455 and select Option 2
REGISTER YOUR OMNIPOD DASH™ SYSTEM AT PODDERCENTRAL
A Digital Home For Podders™
+ Get Access to Omnipod DASH™ System Online Training!
+ Manage your Omnipod DASH™ account online
Page 4
4
CURRENT USER? START HERE!
+ To set up your new Omnipod DASH
System Personal Diabetes Manager, you need settings from either your current Personal Diabetes Manager (model UST400) or pump therapy settings provided by your healthcare provider.
+ If you currently use the previous
generation Personal Diabetes Manager (model UST400), the instructions to the right will help you find your current settings.
NEW USER? SKIP THIS SECTION
Your Certified Pod Trainer will work with your healthcare provider to obtain your pump therapy settings.
For your safety, please do not attempt to create your own Omnipod DASH™ System Personal Diabetes Manager settings.
3:00p 5/15
Bolus More actions Temp basal My records Settings Suspend
Status Select
3:00p 5/15
Basal Programs Presets System setup Vibration
Back Select
How to Find Your Basal Program(s)
2. Select Basal Programs
3:00p 5/15
Basal programs:
basal 1 basal 2 Weekend [add new]
Back Select
Enable
1. On Home Screen Select Settings
4. You will first see the graph, press List to view your basal segments as shown
+ Take note of
your Total Daily Basal
3. Select the basal program to review. On the next screen, select View
3:00p 5/15
Basal 1: Segment U/hr
12:00a - 8:00a 0.60
8:00a - 3:00p 0.80
3:00p - 12:00a 0.75
Daily basal: 17.15 U
Back Graph
Page 5
3:00p 5/15
Bolus More actions Temp basal My records Settings Suspend
Status Select
3:00p 5/15
Basal Programs Presets System setup Vibration
Back Select
3:00p 5/15
Date/time Bolus/basal/calcs Alerts/reminders BG meter PDM options Diagnostics
Back Select
3:00p 5/15
Bolus calc: On Ratios/factors/targets Temp basal: Off Extended: Off Bolus increment: 0.10U Max bolus: 10.00U Max basal: 3.00U/hr
Back Select
3:00p 5/15
Review all settings Target BG Min BG for calcs: 70 mg/dL IC ratio Correction factor Reverse correction: On Insulin action: 4.0hr
Back Select
How to Find Your Bolus Calculator Settings
5
2. Select System setup
1. On Home Screen Select Settings
3. Select Bolus/basal/ calcs
5. Select Review all settings
4. Select Ratios/ factors/ targets. NOTE: Bolus calcs must be “0n.”
Page 6
6
MY PERSONAL DIABETES MANAGER SETTINGS
You may use the following worksheet to write down your Personal Diabetes Manager settings from your current PDM (model UST400).
6
Page 7
7
1. Maximum Basal Rate _____U/h
_____ to _____ _____U/hr
2. Basal 1
_____ to _____ _____U/hr
Total Daily Basal ______U
_____ to _____ _____U/hr _____ to _____ _____U/hr
3. Temporary Basal Rate On Off
(Select “On” if model UST400 is set
to % or U/Hr. “On” is in %)
4. BG Goal Limits Lower Limit_____mg/dL Upper Limit_____mg/dL
Find in model UST400: Settings>
System Setup>BG Meter>BG Goal
5. Suggested Bolus Calculator On Off
_____ to _____ Target_____ mg/dL Correct Above_____mg/dL
6. Target BG
_____ to _____ Target_____ mg/dL Correct Above_____mg/dL _____ to _____ Target_____ mg/dL Correct Above_____mg/dL _____ to _____ Target_____ mg/dL Correct Above_____mg/dL
7. Min BG – for bolus calculations _____mg/dL
_____ to _____ _____g/carb
8. Insulin-to-Carbohydrate (IC) Ratio
_____ to _____ _____g/carb _____ to _____ _____g/carb _____ to _____ _____g/carb
_____ to _____ _____mg/dL (1 unit of insulin decreases BG by)
9. Correction Factor
_____ to _____ _____mg/dL (1 unit of insulin decreases BG by) _____ to _____ _____mg/dL (1 unit of insulin decreases BG by) _____ to _____ _____mg/dL (1 unit of insulin decreases BG by)
10. Reverse Correction On Off
11. Duration of Insulin Action _____hours
12. Maximum Bolus _____U
13. Extended Bolus On Off
(Select “On” if model UST400 is set
to % or U/Hr. “On” is in %)
12am
12am
12am
12am
Page 8
8
SET UP YOUR OMNIPOD DASH™ SYSTEM PERSONAL DIABETES MANAGER
Be sure to register your Omnipod DASH™ Personal Diabetes Manager (PDM) on PodderCentral™!
+ Use the pull-tab to remove the back cover.
+ Insert the battery into the Personal Diabetes Manager.
+ Remove the pull-tab and replace the back cover.
+ The Personal Diabetes Manager is rechargeable, similar
to common mobile devices.
+ Charge frequency is based on device usage.
We suggest you charge your device during bedtime and stick with a similar time each day.
The Personal Diabetes Manager Battery
Page 9
+ Hold down the Power button
to wake your Personal Diabetes Manager.
+ You will begin by personalizing your new Personal Diabetes
Manager!
+ After personalization, you will enter your insulin delivery settings.
+ The Personal Diabetes Manager guides you step-by-step. Be sure
to read each screen, and accurately enter each setting.
+ For more information, refer to Chapter 2 “Initial PDM Setup” in the
Omnipod DASH™ System User Guide.
Omnipod DASH™ System Initial Personal Diabetes Manager Setup
Your initial pump therapy settings are needed to setup your new Personal Diabetes Manager. These settings are provided to you by your healthcare provider.
9
Page 10
10
PAI R YOUR CONTOUR®NEXT ONE BG METER
1. Tap “BG Meter Pairing Instructions”
If you do not want to pair to a BG meter, tap “SKIP”
2. Follow the on-screen instructions, then tap “START SEARCH”
Pair your CONTOUR®NEXT ONE BG Meter
+ Pair your CONTOUR®NEXT ONE Blood Glucose Meter with your PDM during the initial
setup, or you can do so later through the PDM settings screens. Only readings taken on a paired CONTOUR®NEXT ONE meter will be transferred wirelessly to the PDM’s bolus calculator.
+ BG readings taken on a different meter can only be entered manually. If you do not want to
pair a CONTOUR®NEXT ONE BG Meter at this time, tap SKIP.
Page 11
3. Select the device to pair from available meters
4. Your PDM is now paired with your blood glucose meter
11
Page 12
12
SET UP A NEW POD
1. In the “Pod Info” screen, tap “SET UP NEW POD”
2. Carefully follow the on­screen instructions
Page 13
13
Inject the insulin into the fill port. The Pod beeps twice. Remove the needle from the insulin fill port. Replace the needle’s protective cap and remove the needle from the fill syringe for proper sharps disposal.
NEVER inject air into the fill port. Doing so may result in unintended or interrupted insulin delivery.
NEVER use a Pod if you feel resistance while depressing the plunger of the fill syringe. This condition can result in interrupted insulin delivery.
With the Pod still in its tray place it next to and touching the Personal Diabetes Manager to ensure proper communication. Press “NEXT” on the Personal Diabetes Manager. The system performs a series of safety checks and automatically primes the Pod.
Your Pod is now ready for application and cannula insertion. For more information, please refer to Chapter 3 “Changing your Pod” in your Omnipod DASH™ System User Guide.
Collect the following supplies:
+ Omnipod DASH™ System Personal Diabetes Manager + Unopened Omnipod DASH™ System Pod + Alcohol swabs + Vial of room temperature rapid-acting U-100 insulin
Wash your hands with soap and water. Clean the top of the insulin vial with an alcohol swab.
Remove the fill needle and syringe from the Pod’s tray. Keep the Pod in its tray during set up. Confirm the Pod’s needle cap is blue. This ensures your Pod is compatible with your Omnipod DASH™ System Personal Diabetes Manager. Twist the fill needle clockwise onto the top of the syringe. Do not use any other type of needle or filling device besides the syringe provided with each Pod.
Remove the syringe’s protective cap from the needle. Draw air into the syringe equal to the amount of insulin you will use. You must fill your syringe with at least 85 units of insulin. Insert the needle into the vial and inject air.
Turn the vial upside down and slowly withdraw insulin. Tap or flick the filled syringe to remove any bubbles.
Remove the needle from the vial and insert it into the Pod’s insulin fill port. An arrow on the white paper backing points to the fill port. Do not inject insulin into any other location on the Pod. The Pod should still be in its package during fill.
To ensure proper fill, do not insert the fill syringe at an angle into the fill port.
8
9
1
2
3
4
5
6
7
Page 14
14
KEY INSULIN DELIVERY ACTIONS
Disclaimer: The following screens are for demonstration
purposes only. The values shown are educational and may not reflect real life scenarios.
1. Tap Menu icon on the Home screen
2. Tap “Suspend Insulin” and follow the on-screen instructions
Suspend Insulin Delivery
Page 15
15
1. Tap Menu icon on the Home screen
2. Tap “Set Temp Basal” 3. Tap “Basal Rate” entry box and select your % change. Tap “Duration” entry box and select your time duration. Tap “Confirm”
Set a Temporary Basal Rate
Page 16
16
1. Tap “Basal” tab on the Home screen. Tap “VIEW”
2. Tap “EDIT”
Edit an Active Basal Program
NOTE: You must suspend insulin before editing the active Basal Program.
KEY INSULIN DELIVERY ACTIONS
Disclaimer: The following screens are for demonstration
purposes only. The values shown are educational and may not reflect real life scenarios.
Page 17
17
3. Tap “SUSPEND INSULIN” 4. Tap to edit program name and tag or tap “NEXT” to edit basal time segments and rates
5. Once you are finished editing, tap “RESUME INSULIN”
Page 18
18
KEY INSULIN DELIVERY ACTIONS
Deliver a Bolus
Disclaimer: The following screens are for demonstration
purposes only. The values shown are educational and may not reflect real life scenarios.
1. Tap the “Bolus” icon on the Home screen
2. Tap the “Enter Carbs” entry box to input grams of carbs. Sync or enter your BG manually by tapping the “ENTER BG” entry box
Page 19
3. Review your values, then tap “CONFIRM”
4. Tap “START” to begin bolus delivery
19
Page 20
800-591-3455
978-600-7850
www.myomnipod.com
Insulet Corporation
100 Nagog Park
Acton, MA 01720
© 2018 Insulet Corporation. Omnipod, the Omnipod logo,
DASH, the DASH logo, Podder, and PodderCentral are
trademarks or registered trademarks of Insulet Corporation. All
rights reserved.
18419-USA-ENG-AW Rev. C 10/18
For More Information:
Please refer to your Omnipod DASH™ System User Guide
Visit us online at myomnipod.com
Download the Omnipod® Patient App!
Loading...