1. Notes on this manual
1.1 Scope of Validation
The main purpose of this User’s Manual is to provide instructions and detailed
procedures for installing, operating, maintaining, and troubleshooting the following three
types of Omnik New Energy-Solar Inverters:
• Omniksol-10k-TL3
• Omniksol-13k-TL3
Please keep this user manual all time available in case of emergency.
1.2 Symbols Used
avoided, will result in death or serious injury.
avoided, can result in death or serious injury or moderate
avoided, can result in minor or moderate injury.
damage, if not avoided.
3
NOTICE
Hereby qualified personnel means he/she has the valid license
• Selecti ng and usi ng Personal Protective Equipment (PPE).
WARNING
qualified personnel in accordance with the instructions in
Chapter 5. “Installation”
1.3 Target Group
• Chapter 1, 2, 3, 4, 7, 8, 9, 10 and chapter 11 are intended for anyone who is intended to
use Omnik Grid Tie Solar Inverter. Before any further action, the operators must first
read all safety regulations and be aware of the potential danger to operate high-voltage
devices. Operators must also have a complete understanding of this device’s features
and functions.
Do not use this product unless it has been successfully installed
by
•Chapter 5 and chapter 6 are only for qualified personnel who are intended to instal l
or uninstall the Omnik Grid Tie Solar Inverter.
from the local authorityin:
• Installing electrical equipment and PV power systems (up to
1000 V).
• Applying all applicable installation codes.
• Analyzing and reducing the hazards involved in performing
electrical work.
4
WARNING
The installation, service, recycling and disposal of the
inverters must be performed by qualified personnel only in
dealer to get the information of
Any unauthorized actions including modification of product
functionality of any form will affect the validation of warranty
DANGER
DANGER due to electrical shock and high voltage
prevent risk of electric shock during installation and
2. Preparation
2.1 Safety Instruct ions
DO NOT touch the operating component of the inverter, it
might result in burning or death.
TO
maintenance, please make sure that all AC and DC terminals
are plugged out.
DO NOT stay close to the instruments while there is severe
weather conditions including storm, lighting etc.
compliance with national and local standards and regulations.
Please contact your
authorized repair facility for any maintenance or repairmen.
service; Omnik may deny the obligation of warranty service
accordingly.
5
CAUTION
The PV inverter will become hot during operation; please
don’t touch the heat sink or peripheral surface during or
other components of the
system.
NOTICE
Public utility only
The PV inverter designed to feed AC power directly into the
public utility power grid; do not connect AC output of the
device to any private AC equipment.
shortly after operation.
Risk of damage due to improper modifications. Never modify
or manipulate the inverter or
6
is directly connected to public grid, thus all work to the
might be residual currents in inverter because of large
This device directly connected with electricity generators and public
The components inside the inverter will release a log of heat during
Any unauthorized perforations or modifications are strictly forbidden, if
shall not
2.2 Explanations of Symbols on Inverter
Symbol Description
Dangerous electrical voltage
This device
inverter shall only be carried out by qualified personnel.
DANGER to life due to high electrical voltage!
There
capacitors. Wait 10 MINUTES before you remove the front lid.
NOTICE, danger!
grid.
Danger of hot surface
operation, DO NOT touch aluminum housing during operating.
An error has occurred
Please go to Part 9 “Trouble Shooting” to remedy the error.
This device SHALL NOT be disposed of in residential waste
Please go to Part 8 “Recycling and Disposal” for proper treatments.
Without Transformer
This inverter does not use transformer for the isolation funct ion.
Standards Association of Australian
The inverter complies with the requirement of the AS4777.
CE Mark
Equipment with the CE mark fulfils the basic requirements of the
Guideline Governing Low-Voltage and Electromagnetic Compatibility.
No unauthorized perforations or modifications
any defect or damage (device/person) is occurred, Omnik
take any responsibility for it.
7
3. Product Information
3.1 Overview
• Industrial Layout
• Excellent Heat Elimination
8
3.2 Major Characteristics
Omnik inverter has following characteristics which make Omnik inverter “High Efficiency,
High Reliability, High Cost Eff ective Ratio”
• Wide DC input voltage and current range, enables more PV panels connected.
• Wide MPP voltage range ensure high yield under various weather conditions.
• High MPP tracking accuracy, ensure the minimum power loses during converting.
• Complete set of protection methods.
Also, following protection methods are integrated in Omnik inverter:
• Internal overvoltage
• DC insulation monitoring
• Ground fault protectio n
• Grid monitoring
• Ground fault current monitoring
• DC current monitoring
• Integrated DC switch (Optional)
9
Type
Omniksol-10k-TL3
Omniksol-13k-TL3
Input (DC)
Output (AC)
3/N/PE; 220/380
3/N/PE; 240/415
3/N/PE; 220/380
3/N/PE; 240/415
3.3 Datasheet
Max. PV Power [ W ] 10500 13500
Max DC Voltage [ V ] 1000 1000
Operating MPPT Voltage Range [ V ] 150 - 800 150 - 800
MPPT Voltage Range at Nominal Power [ V ] 350 - 800 450 - 800
Start up DC Voltage [ V ] 200 200
Turn off DC Voltage [ V ] 150 150
Max. DC Current [ A ] A : 20 / B : 10 A : 20 / B : 10
Max. Short Circuit Current for each MPPT [ A ] A : 24 / B : 12 A : 24 / B : 12
Max. inverter back feed current to the array [ A ] A : 0 / B : 0 A : 0 / B : 0
Number of MPP trackers A : 1 / B : 1 A : 1 / B : 1
Number of DC Connection for each MPPT A : 2 / B : 1 A : 2 / B : 1
DC Connection Type MC4 Connector MC4 Connector
Nominal AC Power [ W ] 10000 13000
Nominal Grid Voltage [ V ]
Nominal Grid Frequency [ Hz ] 50 / 60 50 / 60
Max. AC Current [ A ] 17.0 22.0
Maximum output fault current [ A ] 19.0 25.0
Maximum output protection current [ A ] 21.0 28.0
Grid Voltage Range* [ V ] 185 - 276 185 - 276
Grid Frequency Range* [ Hz ] 45 – 55 / 55 - 65 45 – 55 / 55 - 65
Power Factor 0.9 c…0.9 i 0.9 c…0.9 i
Total Harmonic Distortion (THD) < 3% < 3%
Feed in Starting Power [ W ] 30 30
Night time Power Consumption [ W ] < 1 < 1
Standby Consumption [ W ] 10 10
AC Connection Type Plug-in connector Plug-in connector
DC Insulation Monitoring Yes
DC Switch Optional
Residual Current Monitoring Unit (RCMU) Integrated
Grid Monitoring with Anti-islanding Yes
Protection Class I (According to IEC 62103)
Overvoltage Category PV II / Mains III (According to IEC 62109-1)
*The AC voltage and frequency range may vary depending on specific country grid
10
Omniksol-10k-TL3
Omniksol-13k-TL3
Reference Standard
EN 61000-6-1, EN 61000-6-3, EN 61000-6-2, EN 61000-6-4,
G83/1,G59/3, UTE C15-712-1, AS4777, NB/T32004, CEI 0-21
Physical Structure
General Data
Safety Standard EN 62109, AS/NZS 3100
EMC Standard
Grid Standard
Dimensions (WxHxD) [ mm ] 428 * 430 * 187
Weight [ kg ] 27
Environmental Protection Rating IP 65 (According to IEC 60529)
Cooling Concept Natural convection
Mounting Information Wall bracket
Operating Temperature Range [ ℃ ] -25 ~ +60 (derating above 45℃)
Relative Humidity 0% ~ 100%, no condensation
Max. Altitude (above sea level) [ m ] 2000
Noise Level [ dB ] < 40
Class of pollution II
Islanding protection Initiative, Frequency disturbance
DRM command DRM0, DRM5, DRM6, DRM7, DRM8
Isolation Type Transformerless
Display 3 LED,Backlight,20 * 4 Character LCD
Data Communication Interfaces RS485 / WiFi / GPRS optional
Guarantee 5 - 25 years optional
11
A B C D
E F G
4. Packing checklist
4.1 Assembly parts
After you receive the Omnik inverter, please check if there is any damage on the carton,
and then check the inside completeness for any visible external damage on the inv er ter
or any accessories. Contact your dealer if anything is damaged or missing.
Object Quantity Description
A 1 Omnik inverter
B 4pairs DC connector
C 1 AC connector
D 1 Wall mounting bracket
E 4 Screw (ST6×50)
F 4 Expansion tube
G 1 Installation and operating instructions
12
A
D
C
B
B
A
C
4.2 Product Appearance
• Front
Object Description
A LED light (3 pcs)
B Monitoring LCD with bac klighting
C Function keys for displays and choice of lang uage(4 pcs)
• Bottom
Object Description
A DC switch (optional)
B Plug connectors for DC input
C Terminal for grid connection (AC output)
D Communication interface(RS485/GPRS/WiFi/USB)
13
Loading...
+ 32 hidden pages