Omnik Omniksol-10k-TL3, Omniksol-13k-TL3, Omniksol-4k-TL2-TH, Omniksol-5k-TL2-TH, Omniksol-6k-TL2-TH User Manual

User Manual V1.2
User Manual
-Operation
Omniksol-10k-TL3 Omniksol-13k-TL3
Omnik New Energy Co., Ltd.
1
Catalog
1. Notes on this manual ......................................................................................................... 3
1.1 Scope of Validation ....................................................................................................... 3
1.2 Symbols Used ............................................................................................................... 3
1.3 Target Group ................................................................................................................ 4
2. Preparation ........................................................................................................................ 5
2.1 Safety Instructions ......................................................................................................... 5
2.2 Explanations of Symbols on Inverter ............................................................................. 7
3. Product Information ............................................................................................................ 8
3.1 Overview ....................................................................................................................... 8
3.2 Major Characteristics .................................................................................................... 9
3.3 Datasheet .....................................................................................................................10
4. Packing checklist ..............................................................................................................12
4.1 Assembly parts .............................................................................................................12
4.2 Product Appearance ....................................................................................................13
4.3 Product Identification ....................................................................................................14
4.4 Further Information .......................................................................................................14
5. Installation .........................................................................................................................15
5.1 Safety ...........................................................................................................................15
5.2 Mounting Instructions ...................................................................................................16
5.3 Safety Clearance ..........................................................................................................17
5.4 Mounting Procedure .....................................................................................................18
5.5 Safety lock ....................................................................................................................20
6. Electrical Connection ........................................................................................................21
6.1 Safety ...........................................................................................................................21
6.2 AC Side Connection .....................................................................................................21
6.3 DC Side Connection .....................................................................................................22
6.4 Communication and Monitoring Device ........................................................................29
7. Display and Operation ......................................................................................................30
7.1 LCD Panel ....................................................................................................................30
7.2 Commissioning .............................................................................................................31
1
7.3 Operation .....................................................................................................................31
7.4 State Information ..........................................................................................................40
8. Recycling and Disposal .....................................................................................................41
9. Troubleshooting ................................................................................................................42
10. Abbreviation ......................................................................................................................44
11. Contact .............................................................................................................................45
2
NOTICE
NOTICE indicates a situation that can result in property
CAUTION
CAUTION indicates a hazardous condition which, if not
WARNING
WARNING indicates a hazardous situation which, if not
injury.
DANGER
DANGER indicates a hazardous situation which, if not
1. Notes on this manual
1.1 Scope of Validation
The main purpose of this User’s Manual is to provide instructions and detailed procedures for installing, operating, maintaining, and troubleshooting the following three types of Omnik New Energy-Solar Inverters:
Omniksol-10k-TL3
Omniksol-13k-TL3
Please keep this user manual all time available in case of emergency.
1.2 Symbols Used
avoided, will result in death or serious injury.
avoided, can result in death or serious injury or moderate
avoided, can result in minor or moderate injury.
damage, if not avoided.
3
NOTICE
Hereby qualified personnel means he/she has the valid license
Selecti ng and usi ng Personal Protective Equipment (PPE).
WARNING
qualified personnel in accordance with the instructions in
Chapter 5. “Installation”
1.3 Target Group
Chapter 1, 2, 3, 4, 7, 8, 9, 10 and chapter 11 are intended for anyone who is intended to use Omnik Grid Tie Solar Inverter. Before any further action, the operators must first read all safety regulations and be aware of the potential danger to operate high-voltage devices. Operators must also have a complete understanding of this device’s features and functions.
Do not use this product unless it has been successfully installed by
Chapter 5 and chapter 6 are only for qualified personnel who are intended to instal l
or uninstall the Omnik Grid Tie Solar Inverter.
from the local authority in:
Installing electrical equipment and PV power systems (up to 1000 V).
Applying all applicable installation codes.
Analyzing and reducing the hazards involved in performing
electrical work.
4
WARNING
The installation, service, recycling and disposal of the inverters must be performed by qualified personnel only in
dealer to get the information of
Any unauthorized actions including modification of product functionality of any form will affect the validation of warranty
DANGER
DANGER due to electrical shock and high voltage
prevent risk of electric shock during installation and
2. Preparation
2.1 Safety Instruct ions
DO NOT touch the operating component of the inverter, it
might result in burning or death.
TO
maintenance, please make sure that all AC and DC terminals are plugged out. DO NOT stay close to the instruments while there is severe weather conditions including storm, lighting etc.
compliance with national and local standards and regulations. Please contact your authorized repair facility for any maintenance or repairmen.
service; Omnik may deny the obligation of warranty service accordingly.
5
CAUTION
The PV inverter will become hot during operation; please don’t touch the heat sink or peripheral surface during or
other components of the
system.
NOTICE
Public utility only
The PV inverter designed to feed AC power directly into the public utility power grid; do not connect AC output of the device to any private AC equipment.
shortly after operation. Risk of damage due to improper modifications. Never modify or manipulate the inverter or
6
is directly connected to public grid, thus all work to the
might be residual currents in inverter because of large
This device directly connected with electricity generators and public
The components inside the inverter will release a log of heat during
Any unauthorized perforations or modifications are strictly forbidden, if
shall not
2.2 Explanations of Symbols on Inverter
Symbol Description
Dangerous electrical voltage
This device inverter shall only be carried out by qualified personnel.
DANGER to life due to high electrical voltage!
There capacitors. Wait 10 MINUTES before you remove the front lid.
NOTICE, danger!
grid.
Danger of hot surface operation, DO NOT touch aluminum housing during operating.
An error has occurred
Please go to Part 9 “Trouble Shooting” to remedy the error.
This device SHALL NOT be disposed of in residential waste
Please go to Part 8 “Recycling and Disposal” for proper treatments.
Without Transformer
This inverter does not use transformer for the isolation funct ion.
Standards Association of Australian The inverter complies with the requirement of the AS4777.
CE Mark
Equipment with the CE mark fulfils the basic requirements of the Guideline Governing Low-Voltage and Electromagnetic Compatibility.
No unauthorized perforations or modifications
any defect or damage (device/person) is occurred, Omnik take any responsibility for it.
7
3. Product Information
3.1 Overview
Industrial Layout
Excellent Heat Elimination
8
3.2 Major Characteristics
Omnik inverter has following characteristics which make Omnik inverter “High Efficiency, High Reliability, High Cost Eff ective Ratio”
Wide DC input voltage and current range, enables more PV panels connected.
Wide MPP voltage range ensure high yield under various weather conditions.
High MPP tracking accuracy, ensure the minimum power loses during converting.
Complete set of protection methods.
Also, following protection methods are integrated in Omnik inverter:
Internal overvoltage
DC insulation monitoring
Ground fault protectio n
Grid monitoring
Ground fault current monitoring
DC current monitoring
Integrated DC switch (Optional)
9
Type
Omniksol-10k-TL3
Omniksol-13k-TL3
Input (DC)
Output (AC)
3/N/PE; 220/380 3/N/PE; 240/415
3/N/PE; 220/380 3/N/PE; 240/415
3.3 Datasheet
Max. PV Power [ W ] 10500 13500 Max DC Voltage [ V ] 1000 1000 Operating MPPT Voltage Range [ V ] 150 - 800 150 - 800 MPPT Voltage Range at Nominal Power [ V ] 350 - 800 450 - 800 Start up DC Voltage [ V ] 200 200 Turn off DC Voltage [ V ] 150 150 Max. DC Current [ A ] A : 20 / B : 10 A : 20 / B : 10 Max. Short Circuit Current for each MPPT [ A ] A : 24 / B : 12 A : 24 / B : 12 Max. inverter back feed current to the array [ A ] A : 0 / B : 0 A : 0 / B : 0 Number of MPP trackers A : 1 / B : 1 A : 1 / B : 1 Number of DC Connection for each MPPT A : 2 / B : 1 A : 2 / B : 1 DC Connection Type MC4 Connector MC4 Connector
Nominal AC Power [ W ] 10000 13000
Nominal Grid Voltage [ V ]
Nominal Grid Frequency [ Hz ] 50 / 60 50 / 60 Max. AC Current [ A ] 17.0 22.0 Maximum output fault current [ A ] 19.0 25.0 Maximum output protection current [ A ] 21.0 28.0 Grid Voltage Range* [ V ] 185 - 276 185 - 276 Grid Frequency Range* [ Hz ] 45 – 55 / 55 - 65 45 – 55 / 55 - 65 Power Factor 0.9 c…0.9 i 0.9 c…0.9 i Total Harmonic Distortion (THD) < 3% < 3% Feed in Starting Power [ W ] 30 30 Night time Power Consumption [ W ] < 1 < 1 Standby Consumption [ W ] 10 10 AC Connection Type Plug-in connector Plug-in connector
3/N/PE; 230/400
3/N/PE; 230/400
Efficiency
Max. Efficiency 98.0% 98.0% Euro Efficiency 97.5% 97.5% MPPT Efficiency 99.9% 99.9%
Safety and Protection
DC Insulation Monitoring Yes DC Switch Optional Residual Current Monitoring Unit (RCMU) Integrated Grid Monitoring with Anti-islanding Yes Protection Class I (According to IEC 62103) Overvoltage Category PV II / Mains III (According to IEC 62109-1)
*The AC voltage and frequency range may vary depending on specific country grid 10
Omniksol-10k-TL3
Omniksol-13k-TL3
Reference Standard
EN 61000-6-1, EN 61000-6-3, EN 61000-6-2, EN 61000-6-4,
EN61000-3-11, EN61000-3-12
VDE 0126-1-1, VDE-AR-N 4105,RD1663,RD1699,EN50438, C10/11,
G83/1,G59/3, UTE C15-712-1, AS4777, NB/T32004, CEI 0-21
Physical Structure
General Data
Safety Standard EN 62109, AS/NZS 3100 EMC Standard
Grid Standard
Dimensions (WxHxD) [ mm ] 428 * 430 * 187 Weight [ kg ] 27 Environmental Protection Rating IP 65 (According to IEC 60529) Cooling Concept Natural convection Mounting Information Wall bracket
Operating Temperature Range [ ] -25 ~ +60 (derating above 45℃) Relative Humidity 0% ~ 100%, no condensation Max. Altitude (above sea level) [ m ] 2000 Noise Level [ dB ] < 40 Class of pollution II Islanding protection Initiative, Frequency disturbance DRM command DRM0, DRM5, DRM6, DRM7, DRM8 Isolation Type Transformerless Display 3 LEDBacklight20 * 4 Character LCD Data Communication Interfaces RS485 / WiFi / GPRS optional Guarantee 5 - 25 years optional
11
A B C D
E F G
4. Packing checklist
4.1 Assembly parts
After you receive the Omnik inverter, please check if there is any damage on the carton, and then check the inside completeness for any visible external damage on the inv er ter or any accessories. Contact your dealer if anything is damaged or missing.
Object Quantity Description
A 1 Omnik inverter B 4pairs DC connector C 1 AC connector D 1 Wall mounting bracket E 4 Screw (ST6×50) F 4 Expansion tube
G 1 Installation and operating instructions
12
A
D
C
B
B
A
C
4.2 Product Appearance
Front
Object Description
A LED light (3 pcs) B Monitoring LCD with bac klighting C Function keys for displays and choice of lang uage(4 pcs)
Bottom
Object Description
A DC switch (optional) B Plug connectors for DC input C Terminal for grid connection (AC output) D Communication interface(RS485/GPRS/WiFi/USB)
13
Loading...
+ 32 hidden pages