Omega Products TM-3065-240-3P User Manual

F-51
FLANGED IMMERSION HEATERS FOR CLEAN WATER
TM Series
APPLICATIONS
For clean water pH 6 to 8 –
Clean municipal water such as used in washing, rinsing and industrial processes with a pH factor range of pH 6 to pH 8.
For non-corrosive solutions –
Non-corrosive water solutions or weak alkaline or acid content of up to 1% by volume, such as sodium carbonate, sodium chlorate or other neutral salts.
To Order (Specify Model Number)
Dim. E-1 Gen.Purpose Encl1Dim. E-3 Explosion Res. Encl.
2
Dim. E-4 Moisture Res. Encl
1
Dim
Circ. in (cm)
Weight Model in (cm) Model in (cm) Model in(cm)
kW & Ph. B lb (kg) No. Price N No. Price N No. Price N
5 Inch-150 Lb. Steel Flange, 6 Copper Sheath Elements — 45 W/in
2
12 1-3 181⁄16 (46) 30 (14) TM-6125/**/3P $1138 1(3) TM-6125E3/**/3P $1680 11⁄2 (4) TM-6125E4/**/3P $1589 1(3) 15 1-3 193⁄16 (50) 31 (14) TM-6155/**/3P 1173 1(3) TM-6155E3/**/3P 1709 11⁄2 (4) TM-6155E4/**/3P 1627 1(3)
18 1-3 253⁄16 (64) 33 (15) TM-6185/**/3P 1309 1(3) TM-6185E3/**/3P 1850 11⁄2 (4) TM-6185E4/**/3P 1766 1(3) 24 2-3 331⁄16 (84) 37 (17) TM-6245/240/3P 1583 1(3) TM-6245E3/240/3P 2124 11⁄2 (4) TM-6245E4/240/3P 2044 1(3) 24 1-3 331⁄16 (84) 37 (17) TM-6245/480/3P 1583 1 (3) TM-6245E3/480/3P 2124 11⁄2 (4) TM-6245E4/480/3P 2044 1(3) 30 2-3 409⁄16 (103) 40 (18) TM-6305/**/3P 1848 1(3) TM-6305E3/**/3P 2389 11⁄2 (4) TM-6305E4/**/3P 2304 1(3) 40 2-3 521⁄16 (132) 5 1 (23) TM-6405/**/3P 2304 1 (3) TM-6405E3/**/3P 2849 11⁄2 (4) TM-6405E4/**/3P 2759 1(3) 60 2-3 78
1
16 (198) 77 (35) TM-6605/480/3P 3283 1 (3) TM-6605E3/480/3P 3833 11⁄2 (4) TM-6605E4/680/3P 3745 1(3)
To Order (Specify Model Number)
Please note: Approved pressure and/or temperature limited controls must be used to assure safe operation in the event of system malfunctions. See Temperature Section.
/* Add the suffix “/3P” to the model number for 3 phase power. /** Specify voltage, i.e., 240 for 240 VAC or 480 for 480 VAC. Note: Larger flange sizes and kW rating available. Please contact OMEGALUX for specific details. Ordering Example: Model TM-3065/240/3P, is a 6kW heater powered by 3 phase 240 VAC, $762.
Ordering Example: Model TM-6125/480/3P, is a 12kW heater powered by 3 phase 480 VAC, $1138.
1
Heaters with General Purpose and Moisture Resistant Enclosures are UL Listed and CSA Certified. 2Heaters with Explosion Resistant Enclosures are CSA NRTL/C certified and are not intended for use in hazardous areas.
E1 E-2 Moisture Resistant/
Dim. Wt. Gen. Purpose Encl.
1
Dim. Explosion Res.Encl.
2
Dim.
in (cm) Ibs in(cm) in (cm)
kW Circ. B (kg) Model No. Price N Model No. Price N
3 Inch-150 lb. Steel Flange, 3 Copper Sheath Elements — 45 W/in
2
61181⁄16 (46) 16(7) TM-3065/240/* $762 1(3) TM-3065E2/240/* $9653⁄4 (2) 61181⁄16 (46) 16(7) TM-3065/480/* 762 1(3) TM-3065E2/480/* 9653⁄4 (2) 91253⁄16 (64) 17(8) TM-3095/240/* 856 1(3) TM-3095E2/240/* 10513⁄4 (2)
91253⁄16 (64) 17(8) TM-3095/480/* 856 1(3) TM-3095E2/480/* 10513⁄4 (2) 12 1 331⁄16 (84) 18 (8) TM-3125/240 839 11⁄4(3) TM-3125E2/240 1156 1(3) 12 1 331⁄16 (84) 18 (8) TM-3125/240/3P 953 1(3) TM-3125E2/240/3P 11563⁄4 (2) 12 1 331⁄16 (84) 18 (8) TM-3125/480/* 953 1(3) TM-3125E2/480/* 11563⁄4 (2) 15 1 4 09⁄16 (10 3) 20 (9) TM-3155/240 1051 1(3) TM-3155E2/240 1266 11⁄4 (3) 15 1 4 09⁄16 (10 3) 20 (9) TM-3155/240/3P 1051 11⁄4(3) TM-3155E2/240/3P 12663⁄4 (2) 15 1 4 09⁄16 (10 3) 20 (9) TM-3155/480/* 1051 1(3) TM-3155E2/480/* 12663⁄4 (2) 18 1 4 81⁄16 (122) 21(10) TM-3185/240 1141 11⁄4(3) TM-3185E2/240 1344 11⁄4 (3) 18 1 4 81⁄16 (122) 21(10) TM-3185/240/* 1141 1(3) TM-3185E2/240/3P 13443⁄4 (2) 18 1 4 8
1
16 (122) 21(10) TM-3185/480/* 1141 1(3) TM-3185E2/480/* 13443⁄4 (2)
MOST POPULAR ITEMS HIGHLIGHTED
USA
MADE IN
See Page F-40 for Dimensions. †Explosion Resistant Enclosure not
intended for use in Hazardous Areas
General Purpose Terminal Enclosure
1
2
1
Flange Sizes 3" to 5" of
High Grade Steel
General Purpose,
NEMA 1 Rated Enclosure or Moisture Resistant, Explosion Resistant
Enclosure Available
Sturdy 0.475"Diameter
Copper Elements
6 to 150 kW240 and 480 Vac
Power, 1 and 3 Phase
One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com
EPG05
www.omega.com
UNITED KINGDOM
www. omega.co.uk
Manchester, England
0800-488-488
UNITED STATES
www.omega.com
1-800-TC-OMEGA
Stamford, CT.
CANADA
www.omega.ca
Laval(Quebec)
1-800-TC-OMEGA
GERMANY
www.omega.de
Deckenpfronn, Germany
0800-8266342
Karviná, Czech Republic
FRANCE
www.omega.fr
Guyancourt, France
088-466-342
CZECH REPUBLIC
www.omegaeng.cz
596-311-899
BENELUX
www.omega.nl
Amstelveen, NL 0800-099-33-44
More than 100,000 Products Available!
Temperature
Calibrators, Connectors, General Test and Measurement Instruments, Glass Bulb Thermometers, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders Relative Humidity Measurement Instruments, RTD Probes, Elements and Assemblies, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes and Assemblies,Thermocouples Thermowells and Head and Well Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level Measurement, Magnetic Flowmeters, Mass Flowmeters, Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen Instrumentation, Environmental Instrumentation, pH Electrodes and Instruments, Water and Soil Analysis Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems, Communication Products and Converters, Data Acquisition and Analysis Software, Data Loggers Plug-in Cards, Signal Conditioners, USB, RS232, RS485 and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers
Pressure, Strain and Force
Displacement Transducers, Dynamic Measurement Force Sensors, Instrumentation for Pressure and Strain Measurements, Load Cells, Pressure Gauges, Pressure Reference Section, Pressure Switches, Pressure Transducers, Proximity Transducers, Regulators, Strain Gages, Torque Transducers, Valves
Heaters
Band Heaters, Cartridge Heaters, Circulation Heaters, Comfort Heaters, Controllers, Meters and Switching Devices, Flexible Heaters, General Test and Measurement Instruments, Heater Hook-up Wire, Heating Cable Systems, Immersion Heaters, Process Air and Duct, Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters