Vacuum Thermocouple
A
Sensors
With KF Style Flanges
and Integral Cables
TCV-CB Series
U ISO 2861 Fitting Standard 10, 16,
25, and #40
U #10 and #16 Flanged Sensors
Have
and #40 Flanged Sensors Have
1
U 1 m (40") PFA Insulated Cable
with SS Overbraid and Strain Relief
U 304 SS Construction
U Grounded and Ungrounded K, T
or E Thermocouple, Special
Limits of Error
U Optional Probe and Cable Lengths
The OMEGA® TCV-CB style thermocouples can
be installed into an existing KF style flanged
connection. #10 and #16 flanged sensors are
provided with 1⁄8" diameter, and #25 and #40 flanged
sensors are provided with 1⁄4" diameter probes. These
sensors are available with 3", 6" and 12" standard
lengths and ungrounded junctions. Special Limits of
Error (SLE) Type K, T and E calibrations, and 304
stainless steel sheaths and flanges. Cables are
#24AWG stranded thermocouple wires with PFA
Insulation, PFA jacket and stainless steel overbraid
and SMPW connector. Please consult sales for other
probe lengths, cable lengths, grounded junctions or
other options.
1
⁄8
" Diameter Probes, #25
⁄4" Diameter Probes
1
For Use
in Vacuum
Processes
#40 KF flange
fitting, 304 SS.
" diameter
⁄
4
Integral cable
with nylon
cable clamp.
1 m (40") of PFA
with SS over
braid insulated
and jacketed
#24 AWG
thermocouple
cable standard.
SMPW-M connector optional.
Visit omega.com/smpw for details
6"
Probe
length
TCV probe shown installed using customer
supplied clamp and O-ring.
TCV-KU-G-0600-40-CB-40,
shown smaller
than actual size.
Thermocouple Specifications
Thermocouple Temp Range Accuracy
Type at Tip ºC (ºF) (Above 0ºC)
(-328 to 1652) whichever is greater
(-328 to 1652) whichever is greater
(-328 to 752) whichever is greater
-200 to 900 2.2ºC or 0.75
K
-200 to 900 1.7ºC or 0.5
E
-200 to 400 1.0ºC or 0.75
T
To Order Visit omega.com/tcv-cb for Pricing and Details
Model No. KF Flange Thermocouple Type Sheath Diameter
TCV-(*)(**)-(***)-10-CB-40 #10 K, T or E
TCV-(*)(**)-(***)-16-CB-40 #16 K, T or E
TCV-(*)(**)-(***)-25-CB-40 #25 K, T or E
TCV-(*)(**)-(***)-40-CB-40 #40 K, T or E
(*) = Specify Type (“K”, “T” or “E” Thermocouple)
(**) = Specify Junction Style (“G” = Grounded, “U” = Ungrounded)
(***) = Specify the probe length in inches (“0300” = 3", “0600” = 6", “0950” = 9½", “1200” = 12")
For lengths between those shown, indicate the required length as shown above and select the next longer length. Lengths greater than 12",
available for additional cost.
For longer or shorter cable lengths, change “-40” to length in inches. Lengths longer then 40" available for additional cost.
Ordering Examples: TCV-KU-0600-16-CB-40, Type K ungrounded thermocouple with
and SMPW connector.
TCV-TG-0950-40-CB-240, Type T grounded thermocouple with
1
⁄
" diameter probe and #40 flange with 240" of cable and SMPW connector.
4
1
⁄
" diameter probe and #16 flange with 40" of cable
8
A-146
1
⁄
8"
1
⁄
8"
1
⁄
4"
1
⁄
4"