Omega Products TCV-EG-0300-25-CB-40 User Manual

Vacuum Thermocouple
A
Sensors
With KF Style Flanges and Integral Cables
TCV-CB Series
U ISO 2861 Fitting Standard 10, 16,
25, and #40
U #10 and #16 Flanged Sensors
Have and #40 Flanged Sensors Have
1
U 1 m (40") PFA Insulated Cable
with SS Overbraid and Strain Relief
U 304 SS Construction U Grounded and Ungrounded K, T
or E Thermocouple, Special Limits of Error
U Optional Probe and Cable Lengths
The OMEGA® TCV-CB style thermocouples can be installed into an existing KF style flanged connection. #10 and #16 flanged sensors are provided with 1⁄8" diameter, and #25 and #40 flanged sensors are provided with 1⁄4" diameter probes. These sensors are available with 3", 6" and 12" standard lengths and ungrounded junctions. Special Limits of Error (SLE) Type K, T and E calibrations, and 304 stainless steel sheaths and flanges. Cables are #24AWG stranded thermocouple wires with PFA Insulation, PFA jacket and stainless steel overbraid and SMPW connector. Please consult sales for other probe lengths, cable lengths, grounded junctions or other options.
1
8
" Diameter Probes, #25
4" Diameter Probes
1
For Use in Vacuum Processes
#40 KF flange
fitting, 304 SS.
" diameter
4
Integral cable with nylon cable clamp.
1 m (40") of PFA with SS over braid insulated and jacketed #24 AWG thermocouple cable standard.
SMPW-M connector optional. Visit omega.com/smpw for details
6" Probe length
TCV probe shown installed using customer supplied clamp and O-ring.
TCV-KU-G-0600-40-CB-40, shown smaller than actual size.
Thermocouple Specifications
Thermocouple Temp Range Accuracy Type at Tip ºC (ºF) (Above 0ºC)
(-328 to 1652) whichever is greater
(-328 to 1652) whichever is greater
(-328 to 752) whichever is greater
-200 to 900 2.2ºC or 0.75
K
-200 to 900 1.7ºC or 0.5
E
-200 to 400 1.0ºC or 0.75
T
To Order Visit omega.com/tcv-cb for Pricing and Details
Model No. KF Flange Thermocouple Type Sheath Diameter
TCV-(*)(**)-(***)-10-CB-40 #10 K, T or E TCV-(*)(**)-(***)-16-CB-40 #16 K, T or E TCV-(*)(**)-(***)-25-CB-40 #25 K, T or E TCV-(*)(**)-(***)-40-CB-40 #40 K, T or E
(*) = Specify Type (“K”, “T” or “E” Thermocouple) (**) = Specify Junction Style (“G” = Grounded, “U” = Ungrounded) (***) = Specify the probe length in inches (“0300” = 3", “0600” = 6", “0950” = 9½", “1200” = 12")
For lengths between those shown, indicate the required length as shown above and select the next longer length. Lengths greater than 12", available for additional cost.
For longer or shorter cable lengths, change “-40” to length in inches. Lengths longer then 40" available for additional cost. Ordering Examples: TCV-KU-0600-16-CB-40, Type K ungrounded thermocouple with
and SMPW connector. TCV-TG-0950-40-CB-240, Type T grounded thermocouple with
1
" diameter probe and #40 flange with 240" of cable and SMPW connector.
4
1
" diameter probe and #16 flange with 40" of cable
8