Vacuum Thermocouple Assemblies
KF Style Flange with M12 Connector
TCV-M12 Series
U ISO 2861 KF Fittings
Standard Size #10, #16,
#25 and #40
U #10 and #16 Flanged
Sensors Have
1
⁄8" Diameter Probe
U #25 and #40 Flanged
Sensors Have
1
⁄4" Diameter Probes
U M12 Connector with
Thermocouple Pins
U 304 Stainless Steel
Construction
U Grounded or Ungrounded
Type K, T, and E
Thermocouples are
Special Limits of Error
U Single or Dual
Thermocouple
Construction Optional
U Probe Length Optional*
TCV-KU-1200-40-M12
M12CFM-TTJ24S-RFSR-FL-3,
cable assembly.
TCV-KU-0600-40-M12
Both models
shown smaller than
actual size.
M12C-SIL-K-S-F-1.5,
extension cable
assembly.
TCV-KG-0300-16-M12
A
The OMEGA® TVC Series thermocouple
probe assemblies are available in
standard lengths of 3, 6, and 12" with a
grounded or ungrounded thermocouple
junction at the tip. Standard probes are
available in K, T and E calibrations.
* Please call sales for available options including
special probe lengths.
"B" Dia
"A" Dia
Thermocouple Specifications
Thermocouple Type Temperature Range at Tip ºC (ºF) Accuracy (Above 0ºC)
Size mm (inch) mm (inch)
#10 30 (1.18) 12.2 (.48)
#16 30 (1.18) 17.2 (.68)
#25 40 (1.57) 26.2 (1.03)
#40 50 (1.97) 41.2 (1.62)
Unsure of your flange size, verify it by using this size chart.
Mounting Flange Guide
A Dia B Dia
-200 to 900 (-328 to 1652) 2.2ºC or 0.75 whichever is greater
-200 to 900 (-328 to 1652) 1.7ºC or 0.5 whichever is greater
-200 to 400 (-328 to 752) 1.0ºC or 0.75 whichever is greater
To Order Visit omega.com for Pricing and Details
Model No. KF Flange Thermocouple Type Sheath Diameter
TCV-(*)(**)-(***)-10-M12 #10 K, T or E
TCV-(*)(**)-(***)-16-M12 #16 K, T or E
TCV-(*)(**)-(***)-25-M12 #25 K, T or E ¼"
TCV-(*)(**)-(***)-40-M12 #40 K, T or E ¼"
(*) = Specify Type (“K”, “T” or “E” thermocouple).
(**) = Specify junction style (“G” = grounded, “U” = ungrounded).
(***) = Specify the probe length in inches (“0300” = 3", “0600” = 6", “0950” = 9 ½", “1200” = 12").
For lengths between those shown, indicate the required length as shown above and select the next longer length price. For lengths greater than
12", add the additional cost per inch to the 12" price.
Ordering Examples: TCV-KU-0600-16-M12, Type K ungrounded thermocouple with
TCV-TG-0950-40-M12, Type T grounded thermocouple with
1
⁄
" diameter probe and #40 flange with M12 connector.
4
1
⁄
" diameter probe and #16 flange with M12 connector.
8
1
⁄
8"
1
⁄
8"
A-1