OMEGA-FLO® 2-WAY GEnErAL
PurPOsE sOLEnOid VALVEs
SV3300 Series
U Ideal for Compressed Air,
Inert Gas, Water and
Synthetic Oils
U Available in Normally Open
or Normally Closed
U Process Temperature
to 137°C (280°F)
U 8 W, AC Coils Standard,
12 or 14 W, AC or DC
Coils Available
SV3301 shown
larger than
actual size.
SV-3300 Series 2-way solenoid
valves are direct-acting valves
featuring brass, stainless steel
construction and FKM seal
material. The temperature range
from -10 to 137°C (14 to 280°F)
is ideal for neutral media such
as compressed air, inert gases,
water, and synthetic oils.
A strain-relief connector is
supplied with each unit. A
¹⁄₂" conduit plug is also available.
SPECIFICATIONS
Mounting Position: Any (preferably with
solenoid system upright)
Maximum Process Temperature:
137°C (280°F) due to FKM O-ring
Maximum Ambient Temperature:
Coil Dependent (See ratings on coils)
Voltage Tolerance: ±10%
Opening Time (msec):
AC: 10 to 20
DC: 20 to 80 depending on orifice
and pressure
Closing Time (msec):
AC and DC: 20 to 30 approximately
Cycling Rate: Approx. 1000 cpm
Duty Cycle: Continuous (100%)
Coil Molding Material:
Black Polyester (Class F):
SV8COIL-115AC
SV8COIL-24DC/60HZ
SVCOIL-24AC/50 to 60HZ
SV8COIL-220AC
Black Polyamide (Class F):
SV8COIL-12DC, SV8COIL-24DC,
all 12 Watt coils
Black Polyphenylensulphide (Class H):
SV8COIL-115/60HZ
Black Epoxy Resin (Class H):
All 14 Watt coils
J-13
Materials of Construction
Body Brass
Armature Tube Stainless Steel 300
Fixed Core Stainless Steel 400
Plunger Stainless Steel 400
Spring Stainless Steel 300
Shading Ring Copper
Orifice ≤1⁄8" Stainless Steel 300
Orifice >1⁄8" Brass
Sealing Material FKM
Coil Specifications
Coil Inrush VA Holding VA
8 W 25 14
12 W 36 23
14 W 43 27
Normally Closed
F
E
SV3300 Valve Dimensions
D
Valve Dimensions
Pipe Size A B C
¹⁄₈" 1³⁄₃₂" 3¹⁄₁₆" 1⁵⁄₈"
¹⁄₄"
Coil Dimensions
Watt D E F
B
8 1³⁄₁₆" 1²¹⁄₃₂" 2¹⁄₈"
12 1⁷⁄₁₆" 1²⁹⁄₃₂" 2³⁄₈"
14 2¹⁄₁₆" 2⁵⁄₃₂" 2⁵⁄₈"
C
To Order Visit omega.com/sv3300 for Pricing and Details
A
Operating Pressure
Normally Closed Normally Open Coils M.O.P.D.*
Pipe† Orifice Cv Flow MIN AC DC
Model No. Model No. Size Size Factor Standard Optional psi psi psi
SV3301 SV3301-NO ¹⁄₈" ¹⁄₁₆" 0.10 8 W — 0 435 260
SV3302 SV3302-NO
¹⁄₈" ⁵⁄₆₄" 0.14 — 12 or 14 W 0 505 435
SV3303 SV3303-NO
¹⁄₈" ³⁄₃₂" 0.22 — 12 or 14 W 0 435 360
SV3304 SV3304-NO
¹⁄₈" ¹⁄₈" 0.28 — 12 or 14 W 0 360 260/290‡
SV3305 SV3305-NO
¹⁄₈" ³⁄₁₆" 0.45 — 12 or 14 W 0 170 100/115
¹⁄₈" ⁵⁄₆₄" 0.14 8 W — 0 315 230
¹⁄₈" ³⁄₃₂" 0.22 8 W — 0 200 130
¹⁄₈" ¹⁄₈" 0.28 8 W — 0 145 85
¹⁄₈" ³⁄₁₆" 0.45 8 W — 0 70 30
SV3306 SV3306-NO ¹⁄₄" ¹⁄₁₆" 0.10 8 W — 0 430 260
SV3307 SV3307-NO
¹⁄₄" ⁵⁄₆₄" 0.14 — 12 or 14 W 0 505 435
SV3308 SV3308-NO
¹⁄₄" ³⁄₃₂" 0.22 — 12 or 14 W 0 435 360
SV3309 SV3309-NO
¹⁄₄" ¹⁄₈" 0.28 — 12 or 14 W 0 360 260/290‡
SV3310 SV3310-NO
¹⁄₄" ³⁄₁₆" 0.45 — 12 or 14 W 0 170 100/115‡
SV3311 SV3311-NO
¹⁄₄" ⁷⁄₃₂" 0.63 — 12 or 14 W 0 100/145‡ 35/70‡
Maximum operational pressure differential. † BSP threads. In most cases BSP and NPT are interchangeable in this size.
*
‡ Rating for 12 W/14 W units as shown.
¹⁄₄" ⁵⁄₆₄" 0.14 8 W — 0 315 230
¹⁄₄" ³⁄₃₂" 0.22 8 W — 0 200 130
¹⁄₄" ¹⁄₈" 0.28 8 W — 0 145 85
¹⁄₄" ³⁄₁₆" 0.45 8 W — 0 70 30
¹⁄₄" ⁷⁄₃₂" 0.63 8 W — 0 45 15
Accessories
Model No. Description
Connectors
SV-CGC Replacement cable grip connector
SV-CC ¹⁄₂" conduit connector
Coils
SV8COIL-115AC Replacement 8 W coil for 110 to 120 Vac/50 to 60 Hz 154°C (310°F) (Class F)
SV8COIL-12DC 8 W coil for 12 Vdc 154°C (310°F) (Class F)
SV8COIL-24DC 8 W coil for 24 Vdc 154°C (310°F) (Class F)
SV8COIL-24AC/60HZ 8 W coil for 24 Vac/50 to 60Hz 182°C (360°F) (Class F)
SV8COIL-220AC 8 W coil for 220 to 240 Vac/50 to 60 Hz 154°C (310°F) (Class F)
SV8COIL-115/60HZ 8 W coil for 115 Vac/60 Hz 182°C (360°F) (Class H)
SV12COIL-120/60HZ 12 W coil for 120 Vac/60 Hz 154°C (310°F) (Class F)
SV12COIL-12DC 12 W coil for 12 Vdc 154°C (310°F) (Class F)
SV12COIL-24DC 12 W coil for 24 Vdc 154°C (310°F) (Class F)
SV14COIL-24DC 14 W coil for 24 Vdc 182°C (360°F) (Class H)
SV14COIL-24/50-60HZ 14 W coil for 24 Vdc/50 to 60Hz 182°C (360°F) (Class H)
SV14COIL-12DC 14 W coil for 12 Vdc 182°C (360°F) (Class H)
Comes complete with operator’s manual, 8 W coil and cable grip connector.
Ordering Examples: SV3309,
SV3303-NO,
1
" normally open valve for
⁄
8
1
" normally closed valve for
⁄
4
3
" orifice.
⁄
32
1
" orifice.
⁄
8
J-14
J