Omega Products SPRTX-M2 Installation Manual

STCTX SERIES
Industrial Thermocouple Connector/Transmitter
INSTRUCTION
SHEET
General Description
The OMEGA®STCTX Series is a medium performance, low cost, Industrial TC (Thermocouple) Connector/Transmitter. The STCTX features an encapsulated micro miniature signal conditioner built into a Universal Thermocouple Connector that converts the microvolt signal from a thermocouple sensor or probe across a dedicated temperature range to an industry standard 2-wire, 4 to 20mA analog output. This analog output can be sent hundreds of feet away from the location of your sensor (probe) to an indicating device, controller, PLC, computer, datalogger or chart recorder. Your STCTX Connector/Transmitter has been factory calibrated to provide maximum performance and should require no field adjustments when received.
Note: Patents & Patents Pending
Unpacking
Remove the packing list and verify that you have received all of your OMEGA equipment. If you have any questions about the shipment, please call Customer Service at:
1-800-622-2378 or 203-359-1660. On the web you can find us at: omega.com e-mail: cservice@omega.com
When you receive the shipment, inspect the container and equipment for any signs of damage. Note any evidence of rough handling in transit. Immediately report any damage to the shipping agent.
The carrier will not honor any damage claims unless all shipping material is saved for inspection. After examining and removing contents, save packing material and carton in the event reshipment is necessary.
The following items are supplied in the box with your STCTX Connector/Transmitter.
• This User's Manual, # M3935A (1 ea.)
• Probe/Connector Locking Clips (2 ea.)
NOTE
M3935A/0810
Shop online at: omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info
STCTX Series Industrial Thermocouple Connector/Transmitter
STCTX Series Thermocouple Connector/Transmitter Models Available
Model No. Description Range
STCTX-J1 with Universal Connector -18 to 121°C (0 to 250°F) STCTX-J2 with Universal Connector -18 to 538°C (0 to 1000°F) STCTX-K1 with Universal Connector -18 to 121°C (0 to 250°F) STCTX-K2 with Universal Connector -18 to 538°C (0 to 1000°F) STCTX-K3 with Universal Connector -18 to 1093°C (0 to 2000°F) STCTX-T1 with Universal Connector -18 to 121°C (0 to 250°F) STCTX-T2 with Universal Connector -18 to 399°C (0 to 750°F)
SPRTX Series RTD Connector/Transmitter Models Available
Model No. Description Range
SPRTX-S1 with Standard Size Connector -99 to 208°C (-146 to 406°F) SPRTX-S2 with Standard Size Connector 2 to 569°C (36 to 1056°F) SPRTX-M1 with Miniature Size Connector -99 to 208°C (-146 to 406°F) SPRTX-M2 with Miniature Size Connector 2 to 569°C (36 to 1056°F)
Recommended Accessories
Regulated Power Supply, OMEGA
®
Part No.: PSR-24L
Shielded 2-conductor cable (100 ft), OMEGA
®
Part No.: TX2-100
2
STCTX Series Industrial Thermocouple Connector/Transmitter
3
Introduction/Safety
Your STCTX Thermocouple Connector/Transmitter has been designed for ease of use and flexibility. It is important that you read this User's Manual completely and follow all safety precautions before operating your unit.
Precautions
1. FOLLOW ALL SAFETY PRECAUTIONS AND OPERATING INSTRUCTIONS OUTLINED IN THIS MANUAL.
2. INSURE PROBE/CONNECTOR SAFETY CLIPS ARE ALWAYS INSTALLED DURING USE.
3. ADD ADDITIONAL SAFE GUARDS TO YOUR SYSTEM IN CRITICAL APPLICATIONS WHERE DAMAGE OR INJURY MAY RESULT FROM PROBE/CONNECTOR SEPARATION OR FAILURE.
4. NEVER EXPOSE THE CONNECTOR/MODULE BODY TO AMBIENT TEMPERATURES ABOVE 85ºC (185ºF) OR BELOW -40°C (-40°F). DAMAGE MAY RESULT.
5. DO NOT OPERATE IN FLAMMABLE OR EXPLOSIVE ENVIRONMENTS.
6. DO NOT USE IN HUMAN, MEDICAL, OR NUCLEAR APPLICATIONS.
7. NEVER OPERATE WITH A POWER SOURCE OTHER THAN WHAT IS SPECIFIED IN THIS MANUAL.
8. REMOVE AND/OR DISCONNECT POWER SOURCE BEFORE ATTEMPTING INSTALLATION OR MAINTENANCE.
9. ALWAYS OPERATE YOUR UNIT WITH THE SHIELD WIRE CONNECTED TO EARTH GROUND.
10. INSTALLATION AND WIRING SHOULD BE DONE BY TRAINED
PROFESSIONALS ONLY.
11. DO NOT OPEN OR DISASSEMBLE YOUR UNIT.
There are no user serviceable parts inside your unit. Attempting to open, repair or service your unit will void your warranty.
NOTE