Connector-Transmitter for
RTDs and Thermocouples
Replace Other Style Transmitters
with a Connector-Transmitter
The Smart Connector
TM
SPRTX/STCTX
Series
Dual locking
clips included.
PR-13-2-100-(3/16)-12-E
RTD probe sold
separately, visit
omega.com/pr-13
U 2-Wire, 4 to 20 mA Output
U Models for 100 Ω,
0.00385 3-Wire RTDs
and J, K, or T
Thermocouples
U Encapsulated Electronics
Housing
U High Accuracy,
Repeatability, and
Stability
U Factory Calibrated—No
Adjustments Required
U Provides “Open Sensor
Wire” Signal Indication
U RTD Model Compensates
for Long Lead Wires
Loop Powered!
The OMEGA® 2-wire connectortransmitters are high-performance,
low-cost, industrial RTD and
thermocouple transmitters. Both
feature an encapsulated micro
miniature signal conditioner built
into a patented connector housing.
The SPRTX signal conditioner
converts the resistive change of
a 100 Ω, 0.00385 RTD sensor
or probe across a dedicated
temperature range into an
industry-standard 2-wire, 4 to
20 mA analog output. The STCTX
signal conditioner amplifies the
non-linear millivolt output of a
Shown actual size.
Contact Sales
for Quantity
Discounts!
thermocouple sensor or probe
across a dedicated temperature
range, providing an amplified,
industry-standard, 2-wire
4 to 20 mA analog output.
Specifications
SPRTX Series
Supply Voltage:
9 to 24 Vdc @ 30 mA max
Output: Linearized 4 to 20 mA
Accuracy: ±0.5% of FS @ 23°C
(73°F) ambient
Repeatability: ±0.25°C (±0.5°F)
Temperature Effect:
±0.0022 mA/°C (±0.0012 mA/°F)
Max Load:
Rmax(Ω) = (Vsupply – 9V)/0.02 A
Standard-Size
RTD Connector-
Transmitter
OMEGA Exclusive!
PATENTED
Miniature 2-wire RTD
connector-transmitter,
shown close to actual size.
Each connector-transmitter
comes fully assembled,
complete with connector,
built-in transmitter and
3 m (10') of cable.
Max Input Lead Resistance: 50V
Transmitter Operating Temp:
-40 to 85°C (-40 to 185°F)
Output Connection: 2-wire,
shielded cable [3 m (10') included]
Approvals: CE marked
Weight: 110 g (0.25 lb) max with cable
UNIVERSAL CONNECTOR
ON THERMOCOUPLE MODELS
Female connector fits
both standard and
miniature probe
connectors.
“FITS ALL”
Actual size.
Just Plug Your
Probe in and
You’re “Wired”!
N-33
Two-Wire Transmitter Built into a
Thermocouple Connector!
Dual locking
clips included.
Shown
actual size.
3 m (10')
cable
included.
Universal connector-
transmitter with write-on
window included.
PATENTED
KQXL-14U-12 Super
OMEGACLAD® XL Probe,
visit omega.com/jqin
SPRTX Series for RTDs
Range:
SPRTX-M1, SPRTX-S1:
-99 to 208°C (-146 to 406°F)
SPRTX-M2, SPRTX-S2:
2 to 569°C (36 to 1056°F)
Input: 3-wire, PT100 (a = 0.00385)
Open Sensor Wire Indication:
Leg 1: Open = 27 mA
Leg 2: Open = 2.2 mA
Leg 3: Open = 2.2 mA
Input Connection:
SPRTX-M1, SPRTX-M2:
3-prong miniature connector
(MTP-U-F)
SPRTX-S1, SPRTX-S:
3-prong standard-size connector
(OTP-U-F)
Dimensions:
SPRTX-M1, SPRTX-M2:
24 H x 18 W x 79 mm L
(0.96 x 0.70 x 3.12")
SPRTX-S1, SPRTX-S2:
36 H x 18 W x 83 mm L
(1.43 x 0.70 x 3.25")
STCTX Series for
Thermocouples
Range by Model:
STCTX-J1, -K1, -T1: -18 to 121°C
(0 to 250°F)
STCTX-J2, -K2: -18 to 538°C
(0 to 1000°F)
STCTX-K3: -18 to 1093°C
(0 to 2000°F)
STCTX-T2: -18 to 399°C
(0 to 750°F)
Input: Thermocouple signal
(ungrounded sensors only)
Type J, K or T by model
Open Sensor Indication: 22 to 27 mA
Input Connection: Universal
thermocouple connector (UST Series)
Supply Voltage: 9 to 24 Vdc @ 30 mA
Output: 4 to 20 mA (2-wire)
Accuracy: ±0.5% of full scale millivolt
input @ 23°C (73°F) plus the
non-linearity of the thermocouple
type (Note: The STCTX does not
compensate for thermocouple
non-linearity)
Ambient Temp Effect: ±0.015 mA/°C
Max Loop Load:
V = (Vsupply – 9V)/0.020 A
Transmitter Operating Temp:
-40 to 85°C (-40 to 185°F)
Approvals: CE marked
Output Connection: 2-wire shielded
cable [3 m (10') included]
Response Time: 120 ms
(0 to 63% FS)
Interfaces with Standard
4 to 20 mA Instrumentation
Model DPi8 shown smaller
than actual size, visit omega.com
To Order Visit omega.com/sprtx_stctx for Pricing and Details
Model No. Description
SPRTX-(*)1 RTD connector-transmitter, range: -99 to 208°C (-146 to 406°F)
SPRTX-(*)2 RTD connector-transmitter, range: 2 to 569°C (36 to 1056°F)
STCTX-(**) Thermocouple connector-transmitter, with universal connector
Insert “M” for miniature RTD connector or “S” for standard-size RTD connector.
*
Add range, J1, J2, K1, K2, K3, T1 or T2.
**
Accessories
Model No. Description
TX2-100 2-conductor shielded cables, 30 m (100')
PSR-24S Regulated power supply, 24 Vdc, 400 mA, screw terminal
PSR-24L
PSR-24L-230 Regulated power supply, 2stripped leads, 230 Vac input, CE
CAL-3 NIST-traceable calibration with data
CAL-3-SYSTEM CAL-3 calibration with probe
Each connector-transmitter comes fully assembled, complete with connector, built-in
transmitter and 3 m (10') of cable.
Note: The SPRTX and STCTX Series are not for use in medical or nuclear applications, nor in
flammable or explosive environments.
Ordering Example: SPRTX-S2, RTD standard size connector-transmitter with high
temperature range, PSR-24L power supply.
Regulated power supply, 24 Vdc, 400 mA, UL, stripped leads