Omega Products SA2C-RTD-3-100-B-40 User Manual

Flexible Molded RTD Surface Sensors
U Flexible Sensors Mount to Any Shape U Temperature Range: -50 to 200°C U Precision 100 Ω, Class “B” DIN
Platinum Element
for Easy Mounting
SA2C-RTD
Series
#26 AWG stranded nickel-
SA2F-RTD-3-100-B-40 shown smaller than actual size.
plated copper, PFA insulated and jacketed cable, 1 m (40")
long standard
U Available in Two Configurations U Stripped Leads Standard, Connector
Options Available
U PFA Insulated Cables U 4-Wire Configuration Standard
2"
0.63" SA2C-RTD-3-100-B-40 shown
smaller than actual size.
C
1.38"
0.5"
Thickness: 6.4 mm (0.25") max
To Order Visit omega.com/sa2c_sa2f-rtd for Pricing and Details
Model Number Resistance Number of Wires Wire Length SA2C-RTD-3-100-B-40 100 Ω, Class “B” DIN Platinum 4 1 m (40") SA2C-RTD-3-100-B-80 100 Ω, Class “B” DIN Platinum 4 2 m (80") SA2C-RTD -3-100- B -120 100 Ω, Class “B” DIN Platinum 4 3 m (120") SA2F-RTD-3-100-B-40 100 Ω, Class “B” DIN Platinum 4 1 m (40") SA2F-RTD-3-100-B-80 100 Ω, Class “B” DIN Platinum 4 2 m (80") SA2F-RTD - 3 -100-B-120 100 Ω, Class “B” DIN Platinum 4 3 m (120")
Options: For longer cable lengths, change “-120” in model number to length needed, per foot, for additional cost. For Class “A” elements, change “-B” to “-A” in model number for an additional cost. For miniature connectors add “-MTP” to model number for an additional cost. For a TA3F audio connector, add “-TA3F” to model number for an additional cost.
Ordering Examples: SA2C-RTD-3-100-B-80, 4-wire 100 Ω, Class “B” element and 80" of lead wire. SA2F-RTD-3-100-B-40, 4-wire, 100 Ω, Class “B” element with 40" of lead wire.