Omega Products S8VS-03012 User Manual

DC POWER SUPPLY
15 TO 480 WATTS WITH BUILT-IN MULTI-METER
S8VS Series
Starts at
$
S8VS-06024A, power supply, 24 Vdc, 2.5 A, with display, $187.
l Smart Display Simplifies
Troubleshooting of DC Supply Problems Inside the Control Cabinet
l Built-In Functionality of a
Multimeter on the Power Supply
l Instant Read-Out Of: Output
Voltages, Output Currents, Peak Hold Currents, Remaining Service Life of Power Supply
l Ultra-Compact, DIN Rail Mount l Unique Led Displays for
Diagnostics (60 to 480 W Models)
l Protect Critical Processes Against
Line Power Brownouts
l Constant Output Maintained Even
with a 10% Input Voltage Sag
l Meets SEMI F47 Requirements l Universal Supply Voltage
(85 to 264 Vac; 50/60 Hz)
Engineers and plant managers searching for ways to improve equipment uptime and reduce overall operating costs are finding smarter components, such as OMEGA’s S8VS Series switching power supplies with built-in diagnostic displays, essential to support their preventive maintenance programs and shorten troubleshooting inside the control panel.
The S8VS responds to their needs with a reliable power supply combined with a Smart Display™ that provides operators with at-a-glance status of output voltage, output current and peak hold current. On display models, the display and alarm output indicate the power supply’s remaining service life signaling time for maintenance or replacement. The single-phase, single output AC-to-DC power supplies are available with display on models ranging from 60 to 480 W. In addition, the S8VS features overload and overvoltage protection. For increased safety, the overload protection function allows the power supply to shutdown automatically if the outputs are shorted or if there is excessive current flow in the output.
All models shown smaller than actual size.
S8VS-09024A, power supply, 24 Vdc, 3.75 A,with display, $239.
To order, see page M-7.
S8VS-06024, power supply, 24 Vdc, 2.5 A, no display, $124.
M-1
SPECIFICATIONS
15 AND 30 W RATINGS/CHARACTERISTICS
POWER RATINGS 15 W 30 W
ITEM TYPE STANDARD STANDARD
5V Models 72% min 70% min
Efficiency (Typical) 12V Models 74% min 76% min
Voltage Frequency
*1
*1
Current
Power Factor
Input Harmonic Current Emissions Conforms to EN61000-3-2
Leakage Current
Inrush Current
Voltage Adjustment Range Ripple 2.0% (p-p) max (at rated input/output voltage) Input Variation Influence 0.5% max (at 85 to 264 Vac input, 100% load) Load Variation Influence
Output (Rated Input Voltage)
Temperature Variation Influence 0.05%/°C max
Startup Time
Hold Time 20 ms min (at rated input/output voltage)
Overload Protection
Overvoltage Protection Yes (a zener diode clamp) Output Voltage Indication No Output Current Indication No Peak-Hold Current Indication No Maintenance Forecast
Monitor Indication
Additional Maintenance Forecast Functions Monitor Output
Total Run Time Monitor Indication No Total Run Time Monitor Output No Undervoltage Alarm Indication Yes (color: red) Undervoltage Alarm Output No Parallel Operation No
Series Operation
Operating Ambient Temperature Refer to the derating curve in engineering data (15 W, 30 W models)
Storage Temperature -25 to 65°C Operating Ambient Humidity 25 to 85% (storage humidity: 25 to 90%)
Dielectric Strength
Insulation Resistance 100 M min (between all outputs and all inputs/PE terminals) at 500 Vdc Vibration Resistance 10 to 55 Hz, 0.375 mm single amplitude for 2 h each in X, Y, and Z directions Shock Resistance 150 m/s2, 3 times each in ±X, ±Y, and ±Z directions
Other Output Indicator Yes (color: green)
EMI
EMS Conforms to EN61204-3 high severity levels
Approved Standards
SEMI F47-0200 (200-Vac input) Weight 160 g (6 oz) max
Refer to page 7 for notes 1 to 4.
*
24V Models 77% min 80% min
100 to 240 Vac (85 to 264 Vac) 50/60 Hz (47 to 450 Hz)
100V Input 0.45 A max 0.9 A max 200V Input 0.25 A max 0.6 A max
100V Input 0.5 mA max 200V Input 1.0 mA max 100V Input 25 A max (for a cold start at 25°C) 200V Input 50 A max (for a cold start at 25°C)
*2
-10 to 15% (with V. ADJ)
2.0% max (5V), 1.5% max (12V, 24V), (with rated input, 0 to 100% load)
100 ms max 1000 ms max (at rated input/output voltage) (at rated input/output voltage)
105 to 160% of rated load current, 105 to 160% of rated load current, automatic reset
*3
voltage drop, intermittent, automatic reset
*4
Yes
No
No
Models with 24V output: possible for up to 2 power supplies (with external diode) models with 5 or 12V output: not possible
(with no icing or condensation)
3.0 kVac for 1 min (between all inputs and outputs; detection current: 20 mA)
2.0 kVac for 1 min (between all inputs and PE terminals; detection current: 20 mA) 1.0 kVac for 1 min (between all outputs and PE terminals; detection current: 20 mA)
Conducted Emissions
Radiated Emissions
Conforms to EN61204-3 EN55011 Class B and based on FCC Class A
Conforms to EN61204-3 EN55011 Class B
UL: UL508 (Listing; Class 2: Per UL1310), UL60950-1, UL1604 (Class I/Division 2) cUL: CSA C22.2 No.14 (Class 2), No.60950-1, No.213 (Class I/Division 2) EN/VDE: EN50178 (=VDE0160), EN60950-1 (SELV) (=VDE0805 Teil 1) According to VDE0106/P100, IP20 (except terminal block)
M-2
SPECIFICATIONS
60 AND 90 W RATINGS/CHARACTERISTICS
POWER RATINGS 60 W 90 W
MAINTENANCE TOTAL MAINTENANCE TOTAL
ITEM TYPE STANDARD MONITOR MONITOR STANDARD MONITOR MONITOR
Efficiency (Typical) 78% min 80% min
Voltage Frequency
Current
*1
*1
100 to 240 Vac (85 to 264 Vac) 50/60 Hz (47 to 450 Hz)
100V input 1.7 A max 2.3 A max 200V input 1.0 A max 1.4 A max
Input Power Factor
Harmonic Current Emissions Conforms to EN61000-3-2
Leakage Current
Inrush Current
100V input 0.5 mA max 200V input 1.0 mA max 100V input 25 A max (for a cold start at 25°C) 200V input 50 A max (for a cold start at 25°C)
Voltage Adjustment Range*2-10 to 15% (with V. ADJ)
Ripple 2.0% (p-p) max (at rated input/output voltage) Input Variation Influence 0.5% max (at 85 to 264 Vac input, 100% load)
Output Load Variation Influence
(Rated Input Voltage) Temperature Variation Influence
1.5% max (with rated input, 0 to 100% load)
0.05%/°C max
Startup Time 1000 ms max (at rated input/output voltage) Hold Time 20 ms min (at rated input/output voltage) Overload Protection 105 to 160% of rated load current, voltage drop, intermittent, automatic reset Overvoltage Protection Output Voltage Indication Output Current Indication
*3
Yes
*4
No
*4
No
Peak-Hold Current Indication*4No Maintenance Forecast
Monitor Indication
Maintenance Forecast Monitor Output
Additional Total Run Time Functions Monitor Indication
Total Run Time Monitor Output
Undervoltage Alarm Indication
*4
*4
Undervoltage Alarm Output Terminals
*4
*4
No
No
No
No
No
No
Parallel Operation No Series Operation Yes for up to 2 power supplies (with external diode)
Operating Ambient Temperature
Refer to the derating curve in engineering data (60, 90, 120, 180, 240, and 480 W models) (with no icing or condensation)
Storage Temperature -25 to 65°C Operating Ambient Humidity 25 to 85% (storage humidity: 25 to 90%)
3.0 kVac for 1 min (between all inputs and outputs/ alarm outputs; detection current: 20 mA)
2.0 kVac for 1 min (between all inputs and PE terminals; detection current: 20 mA)
Dielectric Strength
1.0 kVac for 1 min (between all outputs/ alarm outputs and PE terminals; detection current for standard models: 30 mA, detection current for models with indication monitor: 20 mA)
Other 500 Vac for 1 min (between all outputs and alarm outputs; detection current: 20 mA)
Insulation Resistance
Vibration Resistance
100 M min. (between all outputs/ alarm outputs and all inputs/ PE terminals) at 500 Vdc 10 to 55 Hz, 0.375 mm single amplitude for 2 h each in X, Y, and Z directions
10 to 150 Hz, 0.35 mm single amplitude (5 G max) for 80 min each in X, Y, and Z directions
Shock Resistance 150 m/s2, 3 times for 2 h each in ±X, ±Y, and ±Z directions Output Indicator Yes (color: green)
Conducted Emissions
EMI
Radiated Emissions
Models with indication monitor: Conforms to EN61204-3 EN55011 Class A and based on FCC Class A, Conforms to EN61204-3 EN55011 Class B Conforms to EN61204-3 EN55011 Group 1 Class B and based on FCC Class A
Models with indication monitor: Conforms to EN61204-3 EN55011 Class A, Conforms to EN61204-3 EN55011 Class B EN61204-3 EN55011 Group 1 Class B
EMS Conforms to EN61204-3 high severity levels SEMI F47-0200 (200 Vac input) Weight 330 g (12 oz) max 490 g (17 oz) max
Refer to page 7 for notes 1 to 9.
*
FORECAST RUN TIME FORECAST RUN TIME
The voltage cannot be adjusted for the S8VS-09024S
Yes (selectable) Yes (selectable) Yes (selectable)
Yes (selectable)
*5
*6
*7
No No
No No No
Yes (selectable) Yes (selectable) Yes (selectable)
Yes (selectable)
*5
*6
*7
No
Yes (transistor
Yes (selectable)
No No
output), 30 Vdc max,
50 mA max
Yes (selectable)
No
*9
No
Yes (transistor output), 30 Vdc max, 50 mA max
Yes (selectable) (selectable)
Yes (transistor output)
No
,
30 Vdc max, 50 mA max
*9
Standard models:
*9
Standard models: Conforms to
Yes
*8
M-3
*8
Loading...