Dual Element RTD  
Pipe Plug Sensors
RTD-NPT Series
U Ideal for Use in Pressure Vessel 
Applications, 172 bar (2500 psi) Max
U PFA Insulated Lead Wires 
U High-Accuracy, 100 Ω, Thin-Film 
#26 AWG  
stranded nickelplated copper,  
PFA insulated  
and jacketed.
Class “A” DIN Platinum Elements 
U 3-Wire Construction for Connecting 
to Most Handheld Instruments 
1
⁄4 NPT
1
⁄4 NPT
 To Order 
Model Number  Sensing Element  Cable 
Visit omega.com/rtd-npt for Pricing and Details
 RTD-NPT-72-E-DUAL-MTP 
1
⁄8 NPT
100 Ω Class “A” DIN
  72" L PFA insulated with 
    MTP connectors 
 RTD-NPT-72-E-DUAL-1/8-MTP 
100 Ω Class “A” DIN
 72" L PFA insulated with 
    MTP connectors
RTD-NPT-72-E-DUAL-1/8-MTP-HT 100 Ω Class “A” DIN
 72" L fiberglass insulated 
    with MTP connectors 
 RTD-NPT-72-E-DUAL-MTP-HT-S 
Ordering Examples: RTD-NPT-72-E-DUAL-MTP, dual 100 Ω Class “A” DIN Platinum thin-film elements, 3-wire connections, 1⁄4 NPT mounting thread,  
72" long PFA insulated cables with MTP connectors. RTD-NPT-72-E-DUAL-MTP-HT, dual 100 Ω Class “A” DIN Platinum thin-film elements, 3-wire 
connections, 1⁄4 NPT mounting thread, 72" long fiberglass insulated cables with MTP connectors.
Options: Sensors supplied with MTP connectors standard. For OTP connectors add “-OTP” to model number for an additional cost. For NO connectors 
remove “-MTP” from model number for a subtraction in cost (leads will be stripped). For a 3-pin audio connector, add “-TA3F” to the model number for an 
additional cost. 
100 Ω Class “A” DIN 72" L SST braided fiberglass
insulated with MTP connectors
MTP connectors (with 
mating connector).
RTD-NPT-72-E-DUAL-MTP 
shown smaller than actual size.
Thread Size
1
⁄4 NPT  230ºC (450ºF) 
1
⁄8 NPT  230ºC (450ºF) 
1
⁄8 NPT  480ºC (896ºF) 
  Max Temp
 1⁄4 NPT  480ºC (896ºF) 
Popular Options Include:
CN1A visit 
omega.com/
cn1a
DP461-RTD meter 
visit omega.com/dp460-t
iDRX/iDRN 
signal 
conditioner, 
visit 
omega.com/ 
idrn-idrx
DRF-RTD 
signal 
conditioner 
visit 
omega.com/ 
drf-rtd
How are OMEGA’s Model Numbers Constructed?
Cable Length: 
In Inches
RTD — NPT —  — 
Ordering Example: RTD-NPT-72-E-DUAL-OTP-HT-S, two 100 Ω class “A” DIN, 72" fiberglass insulated, 1⁄4 NPT, 480°C (896°F),  
and OTP connector.
72 
Temperature Coefficient: 
E = European 0.00385 Ω/Ω/°C
E 
— 
DUAL 
C-71
Mounting Thread: 
(Blank) = 1⁄4 NPT 
1
⁄8 = 1⁄8 NPT
1/8
— 
Termination Options: 
TA3F = Audio Connectors 
OTP = OTP Connectors 
(MTP) = MTP Connectors 
(Blank) = Stripped Leads
— 
OTP 
Temperature Range: 
(Blank) = 230ºC max 
HT = 480ºC max
HT 
— 
S = Steel Overbraid 
— 
Cable Options: 
(Blank) = None
S 

Pipe Plug RTD Sensor
RTD-NPT Series
MTP connectors (with 
mating connector).
U Ideal for Use in Pressure Vessel 
Applications, 172 bar (2500 psi) Max
U 6 mm (0.24") Diameter, SST Probe 
U Steel Braided, PFA Insulated 
Lead Wires
#26 AWG stranded 
nickel-plated copper 
conductors with 
PFA jacket and steel 
overbraid.
U High-Accuracy, 100 Ω, Class “A” DIN 
Thin-Film Platinum Element  
(European Curve)
U 3-Wire Construction for Connecting 
to Most Handheld Instruments with Red/ 
Red/White Per ASTM-E-1137
6 mm 
(0.24") 
Dia.
1
12.7 mm  
(0.5")
 To Order 
Model Number  Sensing Element Cable 
Visit omega.com/rtd-npt for Pricing and Details
⁄4 NPT
 RTD-NPT-72-E  
 RTD-NPT-72-E-MTP 
RTD-NPT-72-E-1/8-MTP 100Ω Class “A” DIN 
RTD-NPT-72-E-MTP-HT 100Ω Class “A” DIN 
RTD-NPT-72-E-1/8-MTP-HT 100Ω Class “A” DIN
Ordering Examples: RTD-NPT-72-E-TA3F, 100 Ω Class “A” European curve, single element, with 1⁄4 NPT mounting thread, 72" long PFA insulated cable with  
audio connector. RTD-NPT-72-E-MTP-HT, 100 Ω Class “A” European curve, single element, with 
with steel overbraid. RTD-NPT-72-E-1/8-MTP-HT, Class “A” element, European curve, with 
SST braid.
Options Available: Sensors supplied with MTP connectors, add “-OTP” to model number for an additional cost for each heavy-duty connector, add “-TA3F”  
to model number for an additional cost for each audio connector. For stripped leads (no connector) remove “-MTP” from model number, and subtract from cost.
Popular Options Include:
6 mm 
(0.24") 
Dia.
12.7 mm  
(0.5")
100Ω Class “A” DIN 
100Ω Class “A” DIN
1
⁄8 NPT
 72" L PFA insulated 
 72" L PFA insulated 
 72" L PFA insulated 
 72" L fiberglass insulated 
 72" L fiberglass insulated 
RTD-NPT-72-E 
shown smaller 
than actual size.
1
⁄4 NPT
Strain relief 
spring.
Thread Size
(stripped leads)
1
⁄4 NPT mounting thread, 72" long fiberglass insulated cable 
1
⁄8 NPT mounting thread, 72" long fiberglass insulated cable with 
1
⁄4 NPT  230ºC (450ºF)
1
⁄4 NPT  230ºC (450ºF)
1
⁄8 NPT  230ºC (450ºF)
1
⁄4 NPT  480ºC (896ºF)
1
⁄8 NPT  480ºC (896ºF)
  Max Temp
C
CN3271-R1 high/low limit 
controller visit omega.com
DP25B-RTD 
visit omega.com
1
⁄8 DIN panel meter 
SPRTX, 4 to 20 mA 
transmitter 
visit omega.com
How are OMEGA’s Model Numbers Constructed?
Mounting Thread 
Cable Length: 
In Inches
RTD — NPT ——
Ordering Example: RTD-NPT-72-E-OTP-HT, 100 Ω Class “A” European curve, with  
connector.
72
Temperature Coefficient: 
E = European 0.00385 Ω/Ω/°C
E
C-72
1
⁄8 = 1⁄8 NPT 
(Blank) = 1⁄4 NPT
—
TX92 transmitter 
visit omega.com
Temperature Range: 
(Blank) = 230ºC max 
HT = 480ºC max
OTP
1/8
—
Termination Options: 
TA3F = Audio Connector 
OTP = OTP Connector 
MTP = MTP Connector 
(Blank) = Stripped Leads
1
⁄4 NPT, 72" L fiberglass insulated cable, heavy-duty 
—
HT