Omega Products RTD-2-1PT100KN2515-36-T User Manual

RTD Sensors—Fast Response
Exposed RTD Element with Fiberglass Insulated Lead Wires
ACCURACY
IEC CLASS
(±0.15ºC @ 0ºC)
U Thermal Response (63%)
Less Than 1 Second
U Operating Ranges:
-30 to 300°C (-22 to 572°F) Class A Thin Film Element Styles, -100 to 450°C (-148 to 842°F) Class A Wire Wound Element Styles
U 1 m (40") Long 2-, 3-,
or 4-Wire #26 AWG Stranded Nickel Plated Copper, Fiberglass Insulated and Jacketed Cable Constructions Available
U Ceramic Cement
Insulating Element to Cable Connection
A
RTD-2-1PT100KN2528-36-G
shown actual size.
To Order Visit omega.com/rtd-2-f3105 for Pricing and Details
Resistance at 0° Model No. and Accuracy Element Size Element Type
RTD-2-F3105-36-G 100 ±0.06 Ω, Class A 2 W x 2 mm L Thin film
RTD-2-F3102-36-G 100 ±0.06 Ω, Class A 4 W x 5 mm L Thin film RTD-2-1PT100KN2515-36-G 100 ±0.06 Ω, Class A 1.5 Dia. x 25 mm L Wire wound RTD-2-1PT100KN2528-36-G 100 ±0.06 Ω, Class A 2.8 Dia. x 25 mm L Wire wound RTD-2-F3145-36-G 1000 ±0.60 Ω, Class A 2 W x 2 mm L Thin film RTD-2-F3142-36-G 1000 ±0.60 Ω, Class A 4 W x 5 mm L Thin film
For 2-wire, replace “2” in model number with “1” and subtract cost from price. For 4-wire assembly, replace “2” in model number with “3” and add cost to price. For longer leads, change “-36” in model number to length in inches and add cost for 3- and 4-wire cables or 2-wire cables to the price. For spade style terminal lugs standard termination in stripped leads, add “-LUG” to the model number for additional cost. For connectors (3-wire only) add “-OTP” to the model number for full sized connector or “-MTP” for miniature connector for additional cost.
Ordering Examples: RTD-3-F3105-36-G, 100 Ω, 2 x 2 mm, thin film Pt100 RTD element, Class A accuracy with 4-wire fiberglass insulated cable 1 m (40") long with ceramic cement over connection and stripped leads.
RTD-2-1PT100KN2515-36-G-MTP, 100 Ω, 1.5 Dia. x 25 long mm, Pt100 wire wound element, Class A accuracy with 3-wire fiberglass insulated cable 1 m (40") long with ceramic cement over connection and miniature 3-pin connector.
Popular Options Include:
DP25B-RTD 1⁄8 DIN panel meter,
see omega.com.
OM-DAQPRO-5300
handheld
data logger,
see omega.com.
HH804U,
handheld
meter, see
omega.com.
®
OMEGABOND high temp chemical set cements, visit omega.com/ob_bond_chem_set
C-109
RTD Sensors—Fast Response
Exposed RTD Element with PFA Lead Wires
ACCURACY
IEC CLASS
(±0.15ºC @ 0ºC)
U Thermal Response (63%)
Less Than 1 Second
U High Accuracy Class A, Pt100 and
Pt1000 RTD Elements Standard
U Higher Accuracy
Are Available in Some Styles*
U Operating Range: -30 to 260°C (-22
to 500°F) Class A Thin Film Element Styles, -100 to 260°C (-148 to 500°F) Class A Wire Wound Element Styles
U 1 m (40") Long 2-, 3- or 4-Conductor
#26 AWG Stranded Nickel Plated Copper, PFA Insulated and Jacketed Cable Constructions Available
U Epoxy Potting Insulating Element to
Cable Connection
A
1
3 and 1⁄10 DIN Elements
C
Enlarged
tip view.
Note: Temperature range for
*
and temperature range for Also, note 4-wire configuration only for
1
3 DIN is 0 to 150°C (32 to 302°F)
1
10 DIN is 0 to 100°C (32 to 212°F).
1
10 DIN.
RTD-2-F3105-36-T
shown actual size.
To Order Visit omega.com/rtd-2-f3105 for Pricing and Details
Resistance at 0° Model No. and Accuracy Element Size Element Type
RTD-2-F3105-36-T 100 ±0.06 Ω, Class A 2 W x 2 mm L Thin film
RTD-2-F3102-36-T 100 ±0.06 Ω, Class A 4 W x 5 mm L Thin film RTD-2-1PT100KN2515-36-T 100 ±0.06 Ω, Class A 1.5 Dia. x 25 mm L Wire wound RTD-2-1PT100KN2528-36-T 100 ±0.06 Ω, Class A 2.8 Dia. x 25 mm L Wire wound RTD-2-F3145-36-T 1000 ±0.60 Ω, Class A 2 W x 2 mm L Thin film RTD-2-F3142-36-T 1000 ±0.60 Ω, Class A 4 W x 5 mm L Thin film
For 2-wire, replace “2” in model number with “1” and subtract cost from price. For 4-wire assembly, replace “2” in model number with “3” and add cost to price. For model number for additional cost. (Note: to length in inches and add cost for 3- and 4-wire cables, or 2-wire cables,for an additional cost. For spade style terminal lugs standard termination in stripped leads, add “-LUG” to the model number for additional cost. For connectors (3-wire only) add “-OTP” to the model number for full sized connector, or “-MTP” for miniature connector for additional cost.
Ordering Examples: RTD-3-F3105-36-T-1/3, 100 Ω, 2 x 2 mm, thin film Pt100 RTD element, 1 m (40") long with epoxy over connection and stripped leads.
RTD-2-1PT100KN2515-36-T-MTP, 100 Ω, 1.5 Dia. x 25 long mm, Pt100 wire wound element, Class A accuracy with 3-wire PFA insulated cable 1 m (40") long with epoxy over connection and miniature 3-pin connector.
Popular Options Include:
1
3 DIN accuracy, add “-1/3” to end of model number for additional cost. For 1⁄10 DIN accuracy, add “-1/10” to the
1
10 DIN option is only available in 4-wire construction). For longer leads, change “-36” in model number
1
3 DIN accuracy with 4-wire PFA insulated cable
HE-XT105
PLC/HMI
all-in-one,
see
omega.com.
CN1A temperature controller,
see omega.com.
C-110
CN3271-R1 high/low limit
controller, see omega.com.
OM-SQ2010 data logger,
see omega.com.
Loading...
+ 1 hidden pages