Industrial Grade RTD Sensors
(Class B) 5-Pack with Lead Wires
ACCURACY
IEC CLASS
(±0.30ºC @ 0ºC)
U 2-, 3- or 4-Wire
Configurations Available
U Popular Sensor Styles
Stocked for Immediate Delivery
U Industrial Grade
(Class “B” = ±0.12 Ω
at 0°C) Accuracy
U Sold in Economical 5-Packs
U Same Rugged Sensor
Construction as Our
High-Accuracy Sensors,
at a Lower Price
U Simple, Flexible Sensing
Option for a Wide Variety of
Measurement Applications
B
RTD-2-F3105-36-T-B
shown smaller than
actual size.
Economical Industrial Grade
Omega Exclusive:
Sensors—When Standard
Accuracy is All
You Need
C
To Order Visit omega.com/rtd-2-f3105-dinb-5pk
Potting Maximum
Model Number Element Lead Wire Material Temperature
RTD-2-F3105-36-T-B (shown actual size), 3-wire standard
RTD-2-F3105-36-T-B F3105 (2 x 2 mm) PFA Epoxy 230°C (450°F)
RTD-2-F3102-36-T-B F3102 (4 x 5 mm) PFA Epoxy 230°C (450°F)
RTD-2-1PT100K2515-36-T-B 1PT100K2515 PFA Epoxy 230°C (450°F)
RTD-2-1PT100KN2528-36-T-B 1PT100KN2528 PFA Epoxy 230°C (450°F)
RTD-2-F3102-36-G-B provides larger measuring area (4x) than the F3105 (shown larger than actual size), 3-wire standard
RTD-2-F3105-36-G-B F3105 (2 x 2 mm) Fiberglass Ceramic 480°C (900°F)
RTD-2-F3102-36-G-B F3102 (4 x 5 mm) Fiberglass Ceramic 480°C (900°F)
RTD-2-1PT100K2515-36-G-B (shown larger than actual size), 3-wire standard
RTD-2-1PT100K2515-36-G-B 1PT100K2515 Fiberglass Ceramic 480°C (900°F)
RTD-2-1PT100KN2528-36-G-B 1PT100KN2528 Fiberglass Ceramic 480°C (900°F)
Select Specifications: All sensors are provided with platinum elements with a resistance of 100.00 ±0.12 Ω at 0°C, and a temperature
coefficient (alpha) of 0.00385 Ω/Ω/°C. Sensors are supplied with 1 m (40") of stranded nickel-plated copper lead wire (insulation as specified)
unless longer lengths are ordered. Standard termination is stripped leads. F3102 and F3105 elements are thin film; 1PT100K2515 and
1PT100KN2528 are wire-wound elements.
Ordering Note: Above models shown as 3-wire configurations, for 2-wire construction change the “-2” in the model number to “-1”; for 4-wire
construction change “-2” to “-3”. To order sensors with bare wires and connections for use to 600°C (1112°F), replace “-T” or “-G”
in model number with “-B”. For longer lead wires, change “-36” in the model number to length desired for an additional cost/ft per sensor.
Terminations available: “-LUG” copper lugs, add an additional cost per sensor; for “-OTP” and “-MTP” connectors add an additional cost
per sensor.
Ordering Examples: RTD-2-1PT100K2515-36-T-B, 1PT100K2515 element with 1 m (40") of 3-conductor PFA insulated cable attached
(epoxy potted), 5 pack. RTD-3-F3102-36-G-B, F3102 element with 1 m (40") of 4-conductor fiberglass-insulated cable attached (ceramic
potting), 5 pack. RTD-2-F3105-36-T-B-OTP, F3105 element with 1 m (40") of 3-conductor PFA insulated cable, epoxy potted and heavy-duty
connectors, 5 pack.
C-64