Omega Products RHXL-3SD Installation Manual

omega.com
e-mail: info@omega.com
For latest product manuals:
omegamanual.info
RHXL-3SD
Thermometer-Hygrometer with
Data Logging SD Card
Shop online at
MADE IN TIAWAN
Servicing North America:
U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047
ISO 9001 Certified Stamford, CT 06907-0047 USA
Toll Free: 1-800-826-6342 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com
Canada: 976 Bergar
Laval (Quebec), H7L 5A1 Canada Toll-Free: 1-800-826-6342 TEL: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca
For immediate technical or application assistance:
U.S.A. and Canada: Sales Service: 1-800-826-6342/1-800-TC-OMEGA
®
Customer Service: 1-800-622-2378/1-800-622-BEST
®
Engineering Service: 1-800-872-9436/1-800-USA-WHEN
®
Mexico/ En Español: 001 (203) 359-7803 FAX: 001 (203) 359-7807 Latin America: info@omega.com.mx e-mail: espanol@omega.com
Servicing Europe:
Benelux: Managed by the United Kingdom Office
Toll-Free: 0800 099 3344 TEL: +31 20 347 21 21 FAX: +31 20 643 46 43 e-mail: sales@omegaeng.nl
Czech Republic: Frystatska 184
733 01 Karviná, Czech Republic Toll-Free: 0800-1-66342 TEL: +420-59-6311899 FAX: +420-59-6311114 e-mail: info@omegashop.cz
France: Managed by the United Kingdom Office
Toll-Free: 0800 466 342 TEL: +33 (0) 161 37 29 00 FAX: +33 (0) 130 57 54 27 e-mail: sales@omega.fr
Germany/Austria: Daimlerstrasse 26
D-75392 Deckenpfronn, Germany Toll-Free: 0800 6397678 TEL: +49 (0) 7056 9398-0 FAX: +49 (0) 7056 9398-29 e-mail: info@omega.de
United Kingdom: OMEGA Engineering Ltd.
ISO 9001 Certified One Omega Drive, River Bend Technology Centre, Northbank
Irlam, Manchester M44 5BD United Kingdom Toll-Free: 0800-488-488 TEL: +44 (0) 161 777-6611 FAX: +44 (0) 161 777-6622 e-mail: sales@omega.co.uk
OMEGAnet®Online Service Internet e-mail
omega.com info@omega.com
It is the policy of OMEGA Engineering, Inc. to comply with all worldwide safety and EMC/EMI regulations that apply. OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification.
The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, human applications.
1
TABLE OF CONTENTS
Introduction .................................................................................................................................... 2
Key features ................................................................................................................................... 2
Operating instructions .................................................................................................................... 3
What’s in the case .............................................................................................................. 3
Setup .................................................................................................................................. 4
Normal operation ............................................................................................................... 6
Holding and storing measurements .................................................................................... 7
Automatic vs. manual datalogging ..................................................................................... 7
Transferring data from the SD card to a computer ............................................................ 8
Specifications ................................................................................................................................. 9
Maintenance & troubleshooting tips .............................................................................................10
Optional accessories ..................................................................................................................... 10
2
INTRODUCTION
Thank you for purchasing Omega's RHXL3SD Thermometer-Hygrometer with Datalogging SD Card. Please read this user’s manual carefully and thoroughly before using the instrument.
The RHXL3SD is a general-purpose handheld instrument that can make four kinds of measurements:
The temperature and humidity (simultaneously)
The dew point of ambient air
The wet-bulb temperature of ambient air
The temperature of a surface
The instrument comes with a temperature-humidity probe that is used to make the first three types of measurement. Surface temperature measurements are made using an optional Type K or Type J thermocouple.
Several features and capabilities enhance the RHXL3SD’s versatility. Among them are automatic temperature compensation for dew point, wet-bulb and thermocouple measurements; the ability to hold readings and display maximum and minimum readings; and an automatic power off function that extends battery life.
Because it is microprocessor-based, the RHXL3SD can make full use of the portability, reliability and large storage capacities that SD memory cards offer. Measurements can be made automatically at any sampling rate between one second and one hour. After the instrument time­stamps and stores the measurements on an SD card plugged into it (a process called datalogging), the user can remove the card and plug it into a laptop or desktop computer either directly or via a USB card reader. The data logs are stored on the card as files with the .xls extension that can be opened by Microsoft’s Excel application.
The RHXL3SD has a backlit 2-1/2 inch diagonal display and is powered by six AA Alkaline batteries or an optional 9-VDC AC adapter.
KEY FEATURES
Four-function instrument measures temperature/humidity, dew point, wet-bulb
temperature and surface temperature
Big (2.5-inch diagonal) front-panel green backlit LCD is easy to read
Displays maximum and minimum readings and holds any reading
Automatically logs measurements at sampling time settable from one second to one hour
Also supports manual datalogging and changing of SD card storage location
Outputs Excel-compatible data logs
Accepts SD memory cards as large as 16 GB
Auto power off function
Powered by six AA batteries or optional 9V AC/DC adapter
3
OPERATING INSTRUCTIONS
What’s in the case
The RHXL3SD comes fully assembled in a soft carrying case along with a temperature-humidity probe, a 2 GB SD memory card and this user’s manual.
Optional accessories available include:
Type K and Type J thermocouples
A 9VDC adapter for a 110VAC power supply
A hard carrying case
See the Optional Accessories section of this manual for more details.
Figure 1 shows all of the controls and indicators on the front, right side, back, top and bottom of the RHXL3SD. It also shows the main components of the included temperature-humidity probe. Familiarize yourself with the positions and functions of these controls, indicators and connectors before moving on to the setup procedure.
1. The RHXL3SD’s controls and indicators and other physical features
[CALLOUTS FOR FIGURE 1] 3-1 Liquid-crystal display 3-2 POWER/ESC button 3-3 FUNC./HOLD/NEXT button 3-4 REC/ENTER button 3-5 SET button 3-6 LOGGER button 3-7 Socket for temperature-humidity probe 3-8 Socket for Type K or J thermocouple thermometer 3-9 SD card socket