
Compressed-Air Dew Point Monitor
RHB-CAC1S2
Standard
U  NIST-Traceable 
U Accuracy: ±0.2°C 
U  Virtually  
Maintenance Free
U Easy to Install 
U  Self-Monitoring  
U  User-Programmable 
Audible and Visual 
Alarms and Relay Contact
U  Programmable Automatic 
Balance Control (ABC)
U Widest Available Range of 
-60 to 50°C (-76 to 122°F)
These compressed-air dew point 
monitors have been designed to 
offer the highest level of reliability 
and accuracy available in such 
systems. They are fully NISTtraceable and employ a chilledmirror sensor, the most accurate 
dew point sensing scheme 
available, to deliver consistent driftfree measurements without regular 
calibrations or sensor replacement.
These compressed-air monitors 
are complete dew point measuring 
systems. The rugged aluminum 
NEMA 12 (IP55) enclosure houses 
the sensor and control circuitry 
(including flow control), and is easily 
wall mounted to conserve space. Only 
the sample line and power connection 
are needed for the system to be 
operational.
The monitors also 
offer a programmable 
automatic balance 
control (ABC) cycle 
that corrects for the 
light-reducing effects of 
mirror contaminants and 
allows for continuous 
monitoring and virtually 
maintenance-free 
operation.
Specifications
Dew/Frost Point Range: 
 2-Stage (S2): 
 -40 to 50°C (-40 to 122°F) 
 3-Stage (S3): 
 -60 to 50°C (-76 to 122°F) 
Dew/Frost Point Accuracy: 
0.2°C (±0.5°F)
Functionality 
Power: 90 to 250 Vac, 
50 to 400 Hz 
Operating Temperature: 
0 to 50°C (32 to 122°F) 
Sample Connection: 
1
⁄4" compression fitting
Sample Flow Rate: 0.5 to 5 SCFH; 
integral flowmeter
Sample Pressure: 0 to 150 psig  
(higher pressures available,  
consult Engineering Department) 
Output:
 Analog: 4 to 20 mA (0 to 5 Vdc), 
 -50 to 50°C (-58 to 122°F) or 
 -60 to 75°C (-76 to 167°F) 
 Compliance: 9.0 Vdc, 450 Ω 
Display: Red LED, 0.5” high; 
8-digit alphanumeric  
Alarm: 
 Audible: >98 dB @ 2' 
 Relay: 1 form “C”, non-latching;   
 10 A @ 240 Vac, 8 A @ 24 Vdc,  
1
⁄2 hp @ 240 Vac 
 Visual: Flashing “ALARM” message
RHB-CAC1S2 
shown smaller than 
actual size.
PR-11-3-100-1/4-6-E-120 
replacement temperature 
probe with 3 m (10')  
cable, shown smaller  
than actual size.
See omega.com 
for more probes.
Standard Features
 U Programmable Automatic
   Balance Control (ABC) 
 U 8-Digit Alphanumeric Display 
 U User-Programmable Alarm 
 U Internal Flowmeter and Valve 
 U Audible and Visual Alarms 
 U Alarm Relay, Form “C” 
 U 4 to 20 mA (0 to 5 Vdc) 
   Analog Output
 U Microprocessor-Controlled 
 U Space-Saving Wall Mount
 To Order 
 Model No.  Description 
 RHB-CAC1S2 
 RHB-CAC1S2-RHB-ATP Compressed-air dew point monitor with 2-stage   
  sensor and temperature probe with 3 m (10') cable 
 RHB-CAC1S2C  Compressed-air dew point monitor with 2-stage   
  sensor and fan cool
 RHB-CAC1S2C-RHB-ATP 
   fan cool, and temperature probe with 3 m (10') cable
 RHB-CAC1S3 
 RHB-CAC1S3-RHB-ATP Compressed-air dew point monitor with 3-stage chill 
  mirror and temperature probe with 3 m (10') cable
Comes complete with operator’s manual and NIST certificate.
Ordering Example: RHB-CAC1S2, compressed-air dew point monitor with 2-stage sensor.
Visit omega.com/rhb-cac1s for Pricing and Details
Compressed-air dew point monitor with 2-stage sensor
Compressed-air dew point monitor with 2-stage sensor, 
Compressed-air dew point monitor with 3-stage chill mirror
Hu-57