Omega Products RD8901 User Manual

Paperless Recorder
RD8900 Series
Starts at
$
2375
Up to 18 Isolated
Analog Inputs
6.1" Color TFT DisplayPlug and Play I/O Cards,
6 Slots
User Friendly with
Auto LCD Shut Off
via Infrared Detector, Prolongs Life and Saves Power
Stores Data on Supplied
128 MB Flash Card
Ethernet Interface
Standard with RS232/422/485 Optional
Windows Graphical
Software Standard and Optional Software for Real Time View
Portable Benchtop Option
The OMEGA®RD8900 Series paperless recorder offers real time display of data in a variety of formats on a high resolution (VGA) color TFT display. The user friendly unit with plug & play cards can easily be set to monitor, record, and evaluate any application. The user can access data on the screen, as well as from a remote site via the standard ethernet or optional RS232/422/485 serial interface. The historical data may be stored in a flash ROM, compact flash card, or collected in a remote host PC for evaluation and print out. The unit's compact size saves space and requires less than 7" behind a panel.
Specifications
Display: 6.1" TFT LCD, 640X480 pixel
resolution, 256 colors
Analog Input Card:
RD8900-AI1, AI2, AI3
Resolution: 18 bits Sampling Rate: 5 times/sec Maximum Rating:
-2 Vdc minimum, 12 Vdc maximum (1 min for mA input)
Temperature Effect: ±1.5 µV/°C for all inputs except mA input ±3.0 µV/°C for mA input
Sensor Lead Resistance Effect: T/C:
0.2 µV/ 3-wire RTD: 2.6°C/ of resistance
difference of 2 leads 2-wire RTD: 2.6°C/ of resistance sum
of 2 leads
Burn-Out Current: 200 nA Common Mode Rejection
Ratio (CMRR): 120 dB Normal Mode Rejection
Ratio (NMRR): 55 dB Isolation Breakdown Voltage Among
Channels: 430 Vac min Sensor Break Detection: Sensor open
for TC, RTD and mV inputs, below 1 mA for 4 to 20 mA input, below 0.25V for 1 to 5V inputs, unavailable for other inputs
S-19
RD8906, $2730.
Sensor Break Responding Time:
Within 10 seconds for TC, RTD and mV inputs, 0.1 second for 4 to 20 mA and 1 to 5V inputs
Digital Input Card (RD8900-DI6)
Channels: 6 per card Logic Low: -30V min, 0.8V max Logic High: 2V min, 30V max External Pull-Down Resistance:
1 k max
External Pull-Up Resistance:
1.5 M min
Digital Output Card (RD8900-DO6)
Channels: 6 per card Contact Form: N O (form A) Relay Rating: 5 A/240 Vac, life cycles
200,000 for resistive load
Comm Module (RD8900-RS)
Interface: RS232 (1 unit), RS485 or
RS422 (up to 247 units)
Protocol: MODBUS®protocol RTU mode Address: 1 to 247
Baud Rate: 0.3 to 38.4 Kbits/sec
Extended Warranty
Program
SM
Data Bits: 7 or 8 bits Parity Bit: None, even or odd Stop Bit: 1 or 2 bits
Standard Ethernet Communication
Protocol: Mod Bus TCP/1P,
10 BaseT; auto polarity correction for 10 BaseT
Ports: AUI (attachment unit Interface) and RJ-45 auto-detect capability
Memory
Storage Memory on Board: 8 MB CF Card: 128 MB standard;
optional 1 GB
Infrared Detector
Distance: Detect moving human body
within 2 m Power: 90 to 264 Vac, 47 to 63 Hz,
60 VA, 30 W max (standard); 11 to 18 or 18 to 36 Vdc 60 VA, 30 W max (optional)
Environmental and Physical
Operating Temperature:
5 to 50°C (40 to 122°F)
Storage Temperature:
-25 to 60°C (-12 to 140°F) Humidity: 20 to 80% RH
(non-condensing) Insulation Resistance: 20 M min
(at 500 Vdc) Dielectric Strength: 3000 Vac
50/60 Hz for 1 min Vibration Resistance: 10 to 55 Hz,
2
10 m/S Shock Resistance: 30 m/S
for operation, 100 g for transportation
Dimensions:
166 W x 144 H x 174 mm D (6.54 x 5.67 x 6.85") for panel mount
Panel Cutout: 138 x 138 mm (5.44 x 5.44")
for 2 hr
2
(3 g)
Approval Standards
Safety: CE; EN61010-1 (IEC1010-1)
Overvoltage category II, pollution degree 2
Protective Class: IP-30 front panel, indoor use, IP-20 housing and terminals
EMC
Emission: EN50081-1, EN61326
(EN55011 class B, EN61000-3-2, EN61000-3-3)
Immunity: EN50082-2, EN61326 (EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11, EN50204)
OMEGACARESMextended warranty program is available for models shown on this page. OMEGACARE covers parts, labor, and equivalent loaners. Ask your sales representative for full details when placing an order.
SM
RD8906, $2730, rear view featuring plug and play I/O cards, shown smaller than actual size.
Characteristics
Accuracy Input
Type Range @25°C Impedance
-120 to 1000°C ±1°C 2.2 M
(-184 to 1832°F)
-200 to 1370°C ±1°C 2.2 M
(-328 to 2498°F)
-250 to 400°C ±1°C 2.2 M
(-418 to 752°F)
-100 to 900°C ±1°C 2.2 M
(-148 to 1652°F)
0 to 1820°C ±2°C 2.2 M
(32 to 3308°F) (200 to 1820°C)
0 to 1767.8°C ±2°C 2.2 M
(32 to 3214°F)
0 to 1767.8°C ±2°C 2.2 M
(32 to 3214°F)
-250 to 1300°C ±1°C 2.2 M
(-418 to 2372°F)
-200 to 900°C ±1°C 2.2 M
(-328 to 1652°F)
PT100 -210 to 700°C ±0.4°C 1.3 k (DIN) (-346 to 1292°F)
PT100 -200 to 600°C ±0.4°C 1.3 k (JIS) (-328 to 1112°F)
mV -8 to 70 mV ±0.05% 2.2 M mA -3 to 27 mA ±0.05% 70.5 0~1V -0.12 to 1.15V ±0.05% 32 k 0~5V -1.3 to 11.5V ±0.05% 332 k 1~5V -1.3 to 11.5V ±0.05% 332 k 0~10V -1.3 to 11.5V ±0.05% 332 k
S-20