Omega Products RD5110 User Manual

Hybrid Chart Recorder
250 mm (10")
RD5100 Series
Starts at
$
6100
High Speed Scanning
at 36 Points/Sec and High-Speed Recording
High Accuracy of 0.05%Various Industrial Values
Can be Measured at the Same Time with Selectable Ranges
Superior Ease of
Operation
Engineering Port is
Provided (USB)
Anti-Noise
Countermeasures
Communication
Interfaces are Available
Recording and
Calculation of Data Communication Input
RD5100 series chart recorders are 250 mm (10") hybrid recorders with multi-range input. Innovative design high performance recorder provides high accuracy, ±0.05%; high speed scanning, 0.1 second for 36 points and high speed recording, 1 line in 3
seconds. and PC setting functions drastically improved usability of recording system.
Simple operational keys
Specifications
Input
Number of Measuring Points:
12, 24 and 36 points Input Types: Universal (refer to the
table of inputs) Range Setting: Input type and range
are set with front keys Scale Setting: The minimum and
maximum values and unit are set for each point with front keys
Setting Range: -30,000 to 30,000
Decimal Points: Optional setting
Indication Accuracy: Refer to the table
of inputs on page S-35d
Temperature Drift: 0.1% FS/ 10°C Measuring Period: 0.1 sec/channel Reference Junction Compensation
Accuracy:
K, E, J, T, N, Platinel II: ±0.5°C
(33°F) or less [0°C (32°F) or more when measuring]
R, S, WRe5-WRe26, NiMo-Ni, U, L:
±1.0°C (34°F) or less [only when the ambient temperature is 23°C (73°F) ±5°C (41°F)]
Input Resolution: Approx. 1/40,000 (standard range conversion)
Burnout: Select with/without burnout for each input
Allowable Signal Source Resistance:
Thermocouple Inputs, DC Voltage Input (10 mV): 500 or less
(without burnout)
DC Voltage Input (Except 10 mV):
100 or less
Resistance Thermometer Inputs:
10 or less/ line, three lines are common, Pt100, JPt100
Input Resistance:
Thermocouple Input, DC Voltage Input: Approx. 1M
Maximum Input Applied Voltage:
±20 Vdc Input Correction: Zero/span correction
and shift correction for each channel
Maximum Common Mode Coltage:
30 Vac (support LVD)
Common Mode Rejection Ratio:
130dB
S-35a
RD5110, $6100.
Series Mode Rejection Ratio: 50dB
(only when the peak value of noise is below standard range)
Terminal Board: Detachable type, removable for wire connection
Recording Specifications
Recording System: Raster scan
system, 10-color wire dot printing
Recording and Recording Color:
Analog Recording: Color can be
specified for each channel as required 10 colors (red, purple-red, orange, brown, green, yellow-green, blue-green, purple, purple-blue, black)
Digital Recording and Logging Recording: Black Message Printing: Black List Printing: Black
Chart Paper: Fan-fold type; overall
width 318 mm (12.5"), total length 20 m (65.6'); effective recording width 250 mm (10") (analog recording)
Chart Speed: 1 to 1500 mm/H [in 1 mm/H steps]
Skip Function: Analog recording, digital recording and digital display can be set independently from recording slip
Recording Compensation:
Independent setting of zero spans are available
Display Specifications
Digital Display: Color LCD panel RGB
(640 x 240 dot) Display Size: 149.8 W x 57.4 mm H
(5.8 W x 2.25" H)
S
Setting Display: Common to digital display*
Display Contents: Digital display
Channel Display: One-point/multiple
points continuous/sequential
indication change
Display Measuring Value of
Each Channel: One-point/multiple
points continuous/sequential
indication change
Clock Display: Hour/Minute/
Second/Tag/Unit
Chart Speed Display Status Display:
Record On: Lights during
recording; LED
Key Lock: Lights during key lock
Alarm: Lights during alarm
activated; LED
Chart End: Lights just before
record ending
Fail: Lights during unit abnormal time
* Sharing LED and setting display
Alarm Specifications
Alarm Display: Occurrence CH No,
data is displayed in red when alarm occurs
Alarm Types: High limit, low limit Alarm Setting Method: Individual
setting for each point four levels/ channels
Alarm Output: See option specification
Setting and Operational Specifications
Key Types, Operation:
Func1: Switching each function
Func2: Switching each function
Enter: Setting a change of parameter
for each mode
Menu: Specifying each setting
function
Esc: Used to escape in the middle
of setting
s: Used to switch channels when
specifying the parameter on cursor
t: Used to switch channels when
specifying the parameter on cursor
s
: Used to move cursor to the right : Used to move cursor to the left
s
Rec: Analog recording, digital
recording, printing, switching chart
ON/OFF
DataP: Digital recording of latest data
Feed: Fast-forwarding chart paper
Shift: Specifying key
. _ =: Setting characters of “. _ =”
@ + -: Setting characters of “@ + -”
0 * /: Setting parameter value 0 and
character of “* / ”
1ABC: Setting parameter value 1 and character of “ABC ”
2DEF: Setting parameter value 2 and character of “DEF”
3GHI: Setting parameter value 3 and character of “GHI”
4JKL: Setting parameter value 4 and character of “JKL”
5MNO: Setting parameter value 5 and character of “MNO”
6PQR: Setting parameter value 6 and character of “PQR”
7STU: Setting parameter value 7 and character of “STU”
8VWX: Setting parameter value 8 and character of “VWX”
9YZ: Setting parameter value 9 and character of “YZ”
Recording Operation:
Record On/Off: Recording operation
ON/OFF*
Data Print: Printing measuring data* Feed: Fast-forwarding chart paper
* Two actions are taken to operate
General Specifications
Rated Power Voltage: 100 to 240 Vac
(universal power supply) 50/60Hz
Maximum Power Consumption: 100V A Reference Operating Condition:
Ambient Temperature/Humidity Range: 21 to 25°C (70 to 77°F),
45 to 65% RH
Power Voltage: 90 to 264V Power Frequency: 50/60Hz ±2% Attitude: Forward/Backward/left/right
within 3°
Warm-Up Time: 1 hour or longer
Normal Operating Condition:
Ambient Temperature/Humidity Range: 0 to 40°C (32 to 104°F),
20 to 80% RH
Power Voltage: 90 to 264V Power Frequency: 50/60Hz ±2% Attitude: Forward/backward/left/right
within 3°
Transportation Condition: At the packed condition on shipment from our factory
Ambient Temperature/Humidity Range: -20 to 60°C (-4 to 140°F),
5 to 90%RH (no dew condensation) Vibration: 10 to 60 Hz, 4.9 m (16')/ S2 (0.5G or less) Impact: 392 m (1.3')/S2 (approx. 40G or less)
Storage Condition:
Ambient Temperature: -20 to 60°C
(-4 to 140°F), 5 to 90% RH (no dew condensation)
Working Condition:
Working Temperature Range:
0 to 40°C (32 to 104°F)
Working Humidity Range:
20 to 80% RH
Power Failure Protection:
Programmed parameters stored into EEPROM memory clock circuit sustained for 5 years or longer by a lithium battery (at the operation of 8 hours or longer per day)
Insulation Resistance:
Between Primary Terminals and Protective Conductor Terminals:
20M or more at 500 Vdc
Between Secondary Terminals and Protective Conductor Terminals:
20M or more at 500 Vdc
Between Primary Terminals and Secondary Terminals: 20M or
more at 500 Vdc
Dielectric Strength:
Between Primary Terminals and Protective Conductor Terminals:
1 minute at 1500 Vac
Between Secondary Terminals and Protective Conductor Terminals:
1 minute at 500 Vac
Between Primary Terminals and Secondary Terminals: 1 minute at
1500 Vac
Option Specifications
Options Comments External Drive Chart 3-speed, chart stop, data printing, list
printing, message printing 5 types, operation recording
Alarm Output Mechanical relay: 12, 24, 36 points output,
max contact capacity of 100 to 240 Vac, 3 A resistance load
External Drive Chart 3-speed, chart stop, data printing, list printing,
message printing 5 types, operation recording
Comm Interface RS-422A or RS-485 + Ethernet + 1a contact output
(1a contact output is contact output of mecha relay)
Chart End Output
Chart End relay output when chart paper ended (communication interface is required)
Fail Output Fail relay output when abnormality (communication
interface is required)
Receiving 250 (for 20 mA) or 100 (for 50 mA) are externally Resistance for mounted to measure current Current Input
S-35b
400 (15.75)
260 (10.24)
380.8 (14.99)
352 (13.86)
28.8 (1.13)
4-M5 The opposite face is the same
245.6 (9.67'') x 385.6 (15.18)
Dimensions: mm (in)
Note 1:
Primary Terminals: Power terminal,
alarm output terminal, output relay
terminal
Secondary Terminals: Measuring
input terminal, communication
terminal, external drive terminal Note 2: When testing insulation
resistance and dielectric strength, please short-circuit every terminals of primary and secondary terminals before the test; test without short-circuiting terminals can damage instruments
Case Assembly Material:
Door (Frame): ABS resin
Front Panel: Soda glass
Back Case: Normal steel Color:
Door (Frame): White (equivalent to
DIC546
Front Panel: Transparent
Back Case: White (equivalent to
DIC546
Mounting: Panel mounting Weight: About 15 kg (33 lb) (full option) Dimensions: 400 W x 260 H x 300 mm D
(15.7 W x 10.2 H x 11.8" D) Panel Cut Dimensions: 388 x 248 mm
(15.2 x 9.7")
Terminal Screws:
Measuring Input, Alarm
Terminals: M3.5
Power, Protective Conductor
Terminal, External Drive Terminal,
Communication Terminal: M4 Chart Paper Illumination: White LED
1
2)
1
2)
Communication Interface Specifications
Without With Communication Communication Interface Interface
Specification Ethernet10BASE-T/
100BASE-T, automated recognition, TCP, IP, — HTTP, exclusive
Ethernet protocol
Function Data display, parameter
setting, with browser data display, parameter — setting on exclusive application
Specification RS-422A, RS-485,
Communication protocol: MODBUS communication — specification: 9600 bps
RS-422A to 19200 bps 7E1 to 8N2 RS-485
Function Data display and
parameter setting using exclusive application
Specification Inside of front door, USB1.1, full speed
USB 12 mbps, bulk transfer, Control transfer
Function Parameter setting for exclusive application
S-35c
S
Communication Interface Specifications
UU
Input Measuring Reference Accuracy Display
Signals Ranges Ranges Ratings Resolutions
-10.0 to 10.0 mV ±10 mV
-20.0 to 20.0 mV ±20 mV
-40.0 to 40.0 mV ±40 mV
DC Voltage -80 0 to 80.0 mV ±80 mV ±0.05% ±1 digit
±0.05% ±1 digit
-1.25 to 1.25V ±1.25V
-2.5 to 2.5V ±2.5V
-5.0 to 5.0V ±5V
-10.0 to 10.0V ±10V
-200 to 500°C (-328 to 932°F) ±20 mV
-200 to 900°C (-328 to 1652°F) ±40 mV
±0.05% ±0.5°C (±33°F)
-200 to 1370°C (-328 to 2498°F) ±80 mV ±0.05% ±1°C (±34°F)
-200 to 250°C (-328 to 482°F) ±20 mV ±0.05% ±0.7°C (±33.2°F)
-200 to 500°C (-328 to 932°F) ±40 mV
-200 to 900°C (-328 to 1652°F) ±80 mV ±0.05% ±1°C (±34°F)
-200 to 350°C (-328 to 662°F) ±20 mV
-200 to 700°C (-328 to 1292°F) ±40 mV
±0.05% ±0.7°C (±33.2°F)
-200 to 1200°C (-328 to 2192°F) ±80 mV ±0.05% ±1°C (±34°F)
-200 to 400°C (-328 to 752°F) ±20 mV ±0.05% ±0.7°C (±33.2°F)
0 to 1760°C (32 to 3200°F) ±20 mV 0 to 1300°C (32 to 2372°F) ±20 mV
0 to 600°C (32 to 1112°F) ±20 mV
0 to 1000°C (32 to 1832°F) ±40 mV 0.1°C (32°F)
±0.05% ±1°C (±34°F)
±0.1% ±0.1°C (±32°F)
0 to 1300°C (32 to 2372°F) ±80 mV
W-WRe26 0 to 2315°C (32 to 4199°F) ±80 mV
PrRh40­PtRh20
0 to 1888°C (32 to 3430°F) ±20 mV
±0.1% ±1°C (±34°F)
NiMo-Ni -50 to 1310°C (-58 to 2390°F) ±80 mV
0 to 500°C (32 to 932°F) ±20 mV ±0.1% ±0.1°C (±32°F)
Platinel II 0 to 950°C (32 to 1742°F) ±80 mV
±0.1% ±1°C (±34°F)
0 to 1395°C (32 to 2543°F) ±80 mV
-200 to 350°C (-328 to 662°F) ±20 mV
-200 to 600°C (-328 to 1112°F) ±40 mV
-200 to 350°C (-328 to 662°F) ±20 mV
±0.05% ±1°C (±34°F)
-200 to 700°C (-328 to 1292°F) ±40 mV
-200 to 900°C (-328 to 1652°F) ±80 mV
-50 to 50°C (-58 to 122°F) 50
Pt100
-100 to 130°C (-148 to 266°F) 100
-200 to 250°C (-328 to 482°F) 200
RTDs Thermocouples
JPt100
-200 to 550°C (-328 to 1022°F) 300
-50 to 50°C (-58 to 122°F) 50
-100 to 130°C (-148 to 266°F) 100
-200 to 250°C (-328 to 482°F) 200
±0.05% ±0.3°C (±32.5°F)
-200 to 550°C (-328 to 1022°F) 300
Note 1: Ambient temperature/humidity range: 23°C ±2°C Note 2: For thermocouple input, the accuracy of reference junction compensation is not included with the accuracy ratings. Note 3: Accuracy rating is the percentage of measuring range K, E, J, T, R, S, B, N: IEC584, JIS C 1602-1995; W-Wre26, Wre5-WRs26,
PtRh40-PtRh20, NiMo-Ni, Platinel?: ASTM Vol.14.03; U(Cu-CuNi), L(Fe-CuNi): DIN43710; Pt100: IEC751, JIS C 1604-1997; JPt100: JIS C 1604-1981, JIS C 1606-1986
S-35d
1 µV
10 µV
100 µV
1 mV
0.1°C (32°F)
Thermocouple DC voltage (-) resistance thermometer B Thermocouple DC voltage (+) resistance thermometer A
Power terminal
Ethernet connector
Upper Comm: RS422A/RS485 terminal Comm. between instruments RS485 terminal
Output relay terminal
Measuring input terminal
Alarm output terminal
Ext. drive terminal
100 to 240V 50/60 Hz
Resistance thermometer terminal B
Terminal Board
Exceptions of Accuracy Ratings
Input Signals Measuring Ranges Accuracy Ratings
K, E, J, T, L -200 to 0°C (-328 to 32°F)
R, S 0 to 400°C (32 to 752°F)
B
U -200 to 0°C (-328 to 32°F)
W-WRe26 0 to 300°C (32 to 572°F)
PrRh40-PtRh20
NiMo-Ni -50 to 100°C (-58 to 212°F) ±0.2% ±1 digit
Note: Refer to thermocouple input accuracy is calculated based on standard range, see page S-35d.
0 to 400°C (32 to 752°F) None
400 to 800°C (752 to 1472°F) ±0.15% ±1 digit
0 to 300°C (32 to 572°F) ±1.5% ±1 digit
300 to 800°C (572 to 1472°F) ±0.8% ±1 digit
S-35e
±0.2% ±1 digit
±0.3% ±1 digit
S
1 channel display
Extended Warranty
Program
SM
OMEGACARESMextended warranty program is available for models shown on this page. Ask your sales representative for full details when placing an order. OMEGACARE covers parts, labor and equivalent loaners.
SM
12 channels simultaneous display
36 channels simultaneous display
Engineering and USB port
Operation key pad
MOST POPULAR MODELS HIGHLIGHTED!
To Order (Specify Model Number)
Model No. Price Description
RD5110 $6100 250 mm (10") 12-points hybrid chart recorder RD5120 7100 250 mm (10") 24-points hybrid chart recorder RD5130 8100 250 mm (10") 36-points hybrid chart recorder RD5111 6770 250 mm (10") 12-points with 12 alarms hybrid chart recorder RD5112 7200 250 mm (10") 12-points with 24 alarms hybrid chart recorder RD5121 7770 250 mm (10") 24-points with 12 alarms hybrid chart recorder RD5122 8200 250 mm (10") 24-points with 24 alarms hybrid chart recorder RD5131 8770 250 mm (10") 36-points with 12 alarms hybrid chart recorder RD5132 9200 250 mm (10") 36-points with 24 alarms hybrid chart recorder RD5133 9650 250 mm (10") 36-points with 36 alarms hybrid chart recorder RD5110-COMM 6540 250 mm (10") 12-points hybrid chart recorder with communications RD5120-COMM 7540 250 mm (10") 24-points hybrid chart recorder with communications RD5130-COMM 8540 250 mm (10") 36-points hybrid chart recorder with communications
Comes complete with operator’s manual. Ordering Example: RD5110, 250 mm (10") hybrid chart recorder $6100. OCW-3, OMEGACARESMextends standard 2-year warranty to a total of
5 years ($350), $6100 + 350 = $6450.
Accessories
Model No. Price Description
RD5100-RC $220 10-color ribbon cassette, package of 5 RD5100-CP-0/100 315 Z-fold chart paper 250 mm x 20 m (9.8" x 65.6'), case of 15 RD9900-ZAILA 110 ZAILA data analysis software RD2800-PASS 270 Parameter programming software RD2800-KIDS 270 Data acquisition software
Recommended Reference Book:
An Introduction to Fuzzy Control,
GE-0544, $73
See Section Y for Additional Books
S-35f
One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com
EPG05
www.omega.com
UNITED KINGDOM
www. omega.co.uk
Manchester, England
0800-488-488
UNITED STATES
www.omega.com
1-800-TC-OMEGA
Stamford, CT.
CANADA
www.omega.ca
Laval(Quebec)
1-800-TC-OMEGA
GERMANY
www.omega.de
Deckenpfronn, Germany
0800-8266342
Karviná, Czech Republic
FRANCE
www.omega.fr
Guyancourt, France
088-466-342
CZECH REPUBLIC
www.omegaeng.cz
596-311-899
BENELUX
www.omega.nl
Amstelveen, NL 0800-099-33-44
More than 100,000 Products Available!
Temperature
Calibrators, Connectors, General Test and Measurement Instruments, Glass Bulb Thermometers, Handheld Instruments for Temperature Measurement, Ice Point References, Indicating Labels, Crayons, Cements and Lacquers, Infrared Temperature Measurement Instruments, Recorders Relative Humidity Measurement Instruments, RTD Probes, Elements and Assemblies, Temperature & Process Meters, Timers and Counters, Temperature and Process Controllers and Power Switching Devices, Thermistor Elements, Probes and Assemblies,Thermocouples Thermowells and Head and Well Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level Measurement, Magnetic Flowmeters, Mass Flowmeters, Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen Instrumentation, Environmental Instrumentation, pH Electrodes and Instruments, Water and Soil Analysis Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems, Communication Products and Converters, Data Acquisition and Analysis Software, Data Loggers Plug-in Cards, Signal Conditioners, USB, RS232, RS485 and Parallel Port Data Acquisition Systems, Wireless Transmitters and Receivers
Pressure, Strain and Force
Displacement Transducers, Dynamic Measurement Force Sensors, Instrumentation for Pressure and Strain Measurements, Load Cells, Pressure Gauges, Pressure Reference Section, Pressure Switches, Pressure Transducers, Proximity Transducers, Regulators, Strain Gages, Torque Transducers, Valves
Heaters
Band Heaters, Cartridge Heaters, Circulation Heaters, Comfort Heaters, Controllers, Meters and Switching Devices, Flexible Heaters, General Test and Measurement Instruments, Heater Hook-up Wire, Heating Cable Systems, Immersion Heaters, Process Air and Duct, Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page
Loading...