SENSOR AND TRANSDUCER
WIRE AND CABLE
CONVENIENT PRE-SPOOLED LENGTHS
FINE-GAGE
INSULATED WIRE
U 3 Mil PTFE Wall
U Single Strand
U Extruded PFA
U Excellent in Vacuum
U Non-Flammable
OMEGA’s thin-wall covering process
guarantees continuous lengths up
to 304 m (1000'). This wire is ideal
for connecting strain gages to solder
terminal strips and pads.
To Order Visit omega.com/px_wire
for Pricing and Details
DIA.
MODEL NO. mm (inch) m (ft)
TFCP-003-50 0.076 (0.003) 15.2 (50)
TFCP-003-100 0.076 (0.003) 30.5 (100 )
TFCP-003-500 0.076 (0.003) 152 (500)
TFCP-005-50 0.127 (0.005) 15.2 (50)
TFCP-005-100 0.127 (0.005) 30.5 (100 )
TFCP-005-500 0.127 (0.005) 152 (500 )
TFCP-010- 50 0.254 (0.010) 15.2 (50)
TFCP-010-100 0.254 (0.010) 30.5 (100 )
TFCP-010-500 0.254 (0.010) 152 (500)
TFCP-015- 50 0.381 (0.015) 1 5. 2 (50 )
TFCP-015-100 0.381 (0.015) 30.5 (100 )
TFCP-015-500 0.381 (0.015) 152 (500)
TFCP-020-50 0.508 (0.020) 15.2 (50)
TFCP-020-100 0.508 (0.020) 30.5 (100 )
TFCP-020-500 0.508 (0.020) 152 (500 )
TFCP-032-50 0.813 (0.032) 15.2 (50)
TFCP-032-100 0.813 (0.032) 30.5 (100 )
TFCP-032-500 0.813 (0.032) 152 (500)
LENGTH
MULTICONDUCTOR
RIBBON CABLE
U 28 AWG 10 to
50 Conductors
U PVC Rating to
105°C (221°F)
U Color Coded
U 30.5 m (100') Rolls
OMEGA’s ribbon cables are
PVC pre-insulated conductors
laminated to a clear PVC film for
easy termination. The color coding
facilitates quick identification and
circuit tracing. For different uses,
the multiconductor ribbon cable
can easily be trimmed to any
desired width.
NO. OF
MODEL NO. COND.
RC4-100
RC10-100 10
RC14-100 14
RC16-100 16
RC20-100 20
RC26-100 26
RC50-100 50
RIBBON LEAD
MULTICONDUCTOR
SHIELDED CABLE
U 24 AWG Tinned
Copper Wires
U PVC Insulation
U Aluminum-Polyester
Shield with #24 Drain Wire
U PVC Jacket Overall
U 30.5 m (100') Rolls
Shielded cable provides the high
conductivity and noise immunity
required for instrumentation
hookups to transducers. It is
suitable for low- and high-level
voltage signals and mA pickup in
high EMI/RFI environments.
4
Flat uninsulated ribbon lead can be used to
make jumper wire connections between the
strain gage solder pads and the bondable
terminal pads. These leads can be soldered
in place, and easily bend to make the small
flex loop.
MODEL NO. DESCRIPTION
RLF-012-004-50 Tinned copper flat wire,
2 µ of tin 0.30 W x 0.10 mm D
(0.0118 x 0.004")
NO. OF NOM OD
MODEL NO.
TX2-100 2
TX4-100 4
TX8-100 8
TX15-100 15
Also available in 200, 500, and 1000' lengths.
COND.
mm (inch)
3.18 (0.125)
4.83 (0.190)
5.59 (0.220)
7.11 (0.280)
ACCESSORIES
C
C-20