SENSOR AND TRANSDUCER
WIRE AND CABLE
CONVENIENT PRE-SPOOLED LENGTHS
FINE-GAGE  
INSULATED WIRE
U 3 Mil PTFE Wall 
U Single Strand 
U Extruded PFA 
U Excellent in Vacuum 
U Non-Flammable
OMEGA’s thin-wall covering process 
guarantees continuous lengths up 
to 304 m (1000'). This wire is ideal 
for connecting strain gages to solder 
terminal strips and pads.
 To Order Visit omega.com/px_wire 
 for Pricing and Details
  DIA. 
MODEL NO. mm (inch)  m (ft)
TFCP-003-50   0.076 (0.003)  15.2 (50)
 TFCP-003-100   0.076 (0.003)  30.5  (100 )
 TFCP-003-500    0.076 (0.003)  152 (500)
 TFCP-005-50   0.127 (0.005)  15.2  (50)
 TFCP-005-100   0.127 (0.005)  30.5  (100 )
 TFCP-005-500   0.127 (0.005)  152  (500 )
 TFCP-010- 50   0.254 (0.010)  15.2 (50)
 TFCP-010-100   0.254 (0.010)  30.5  (100 )
 TFCP-010-500  0.254 (0.010)  152 (500)
 TFCP-015- 50   0.381 (0.015)  1 5. 2 (50 )
 TFCP-015-100  0.381 (0.015)  30.5  (100 )
  TFCP-015-500  0.381 (0.015)  152 (500)
 TFCP-020-50   0.508 (0.020)  15.2  (50)
 TFCP-020-100   0.508 (0.020)  30.5  (100 )
 TFCP-020-500   0.508 (0.020)  152  (500 )
 TFCP-032-50   0.813 (0.032)  15.2  (50)
 TFCP-032-100   0.813 (0.032)  30.5  (100 )
 TFCP-032-500  0.813 (0.032)  152 (500)
LENGTH 
MULTICONDUCTOR 
RIBBON CABLE
U 28 AWG 10 to 
50 Conductors 
U PVC Rating to 
105°C (221°F) 
U Color Coded 
U 30.5 m (100') Rolls
OMEGA’s ribbon cables are 
PVC pre-insulated conductors 
laminated to a clear PVC film for 
easy termination. The color coding 
facilitates quick identification and 
circuit tracing. For different uses, 
the multiconductor ribbon cable 
can easily be trimmed to any 
desired width.
   NO. OF 
 MODEL NO.  COND.
 RC4-100 
 RC10-100 10 
 RC14-100 14 
 RC16-100 16 
 RC20-100 20 
 RC26-100 26 
 RC50-100 50
RIBBON LEAD
MULTICONDUCTOR 
SHIELDED CABLE
U 24 AWG Tinned 
Copper Wires 
U PVC Insulation 
U Aluminum-Polyester 
Shield with #24 Drain Wire
U PVC Jacket Overall 
U 30.5 m (100') Rolls
Shielded cable provides the high 
conductivity and noise immunity 
required for instrumentation 
hookups to transducers. It is 
suitable for low- and high-level 
voltage signals and mA pickup in 
high EMI/RFI environments.
4
Flat uninsulated ribbon lead can be used to 
make jumper wire connections between the 
strain gage solder pads and the bondable 
terminal pads. These leads can be soldered 
in place, and easily bend to make the small 
flex loop. 
 MODEL NO.  DESCRIPTION
 RLF-012-004-50  Tinned copper flat wire, 
   2 µ of tin 0.30 W x 0.10 mm D 
   (0.0118 x 0.004")
   NO. OF  NOM OD 
MODEL NO. 
TX2-100 2 
TX4-100 4 
TX8-100 8 
TX15-100 15
Also available in 200, 500, and 1000' lengths.
COND.
  mm (inch)
  3.18 (0.125)
  4.83 (0.190)
  5.59 (0.220)
  7.11 (0.280)
ACCESSORIES
C
C-20