Omega Products RC10-100 User Manual

SENSOR AND TRANSDUCER
WIRE END
WIRE AND CABLE
CONVENIENT PRE-SPOOLED LENGTHS
FINE-GAGE INSULATED WIRE
U 3 Mil PTFE Wall U Single Strand U Extruded PFA U Excellent in Vacuum U Non-Flammable
OMEGA’s thin-wall covering process guarantees continuous lengths up to 304 m (1000'). This wire is ideal for connecting strain gages to solder terminal strips and pads.
To Order Visit omega.com/px_wire
for Pricing and Details
DIA.
MODEL NO. mm (inch) m (ft)
TFCP-003-50 0.076 (0.003) 15.2 (50)
TFCP-003-100 0.076 (0.003) 30.5 (100 )
TFCP-003-500 0.076 (0.003) 152 (500)
TFCP-005-50 0.127 (0.005) 15.2 (50)
TFCP-005-100 0.127 (0.005) 30.5 (100 )
TFCP-005-500 0.127 (0.005) 152 (500 )
TFCP-010- 50 0.254 (0.010) 15.2 (50)
TFCP-010-100 0.254 (0.010) 30.5 (100 )
TFCP-010-500 0.254 (0.010) 152 (500)
TFCP-015- 50 0.381 (0.015) 1 5. 2 (50 )
TFCP-015-100 0.381 (0.015) 30.5 (100 )
TFCP-015-500 0.381 (0.015) 152 (500)
TFCP-020-50 0.508 (0.020) 15.2 (50)
TFCP-020-100 0.508 (0.020) 30.5 (100 )
TFCP-020-500 0.508 (0.020) 152 (500 )
TFCP-032-50 0.813 (0.032) 15.2 (50)
TFCP-032-100 0.813 (0.032) 30.5 (100 )
TFCP-032-500 0.813 (0.032) 152 (500)
LENGTH
MULTICONDUCTOR RIBBON CABLE
U 28 AWG 10 to
50 Conductors
U PVC Rating to
105°C (221°F)
U Color Coded U 30.5 m (100') Rolls
OMEGA’s ribbon cables are PVC pre-insulated conductors laminated to a clear PVC film for easy termination. The color coding facilitates quick identification and circuit tracing. For different uses, the multiconductor ribbon cable can easily be trimmed to any desired width.
NO. OF MODEL NO. COND.
RC4-100 RC10-100 10 RC14-100 14 RC16-100 16 RC20-100 20 RC26-100 26 RC50-100 50
RIBBON LEAD
MULTICONDUCTOR SHIELDED CABLE
U 24 AWG Tinned
Copper Wires
U PVC Insulation U Aluminum-Polyester
Shield with #24 Drain Wire
U PVC Jacket Overall U 30.5 m (100') Rolls
Shielded cable provides the high conductivity and noise immunity required for instrumentation hookups to transducers. It is suitable for low- and high-level voltage signals and mA pickup in high EMI/RFI environments.
4
Flat uninsulated ribbon lead can be used to make jumper wire connections between the strain gage solder pads and the bondable terminal pads. These leads can be soldered in place, and easily bend to make the small flex loop.
MODEL NO. DESCRIPTION
RLF-012-004-50 Tinned copper flat wire,
2 µ of tin 0.30 W x 0.10 mm D (0.0118 x 0.004")
NO. OF NOM OD
MODEL NO.
TX2-100 2 TX4-100 4 TX8-100 8 TX15-100 15
Also available in 200, 500, and 1000' lengths.
COND.
mm (inch)
3.18 (0.125)
4.83 (0.190)
5.59 (0.220)
7.11 (0.280)
ACCESSORIES
C