Gage Pressure: 25 mb to 40 bar
Absolute Pressure: 350 mb to 40 bar
Compound Gage: ±25 mbar to ±1 bar
Vacuum (Negative Gage): 0 to -25 mbar to 0 to -1 bar
Barometric Ranges: 0,550 or 880 hPa to 1100 hPa
mini DIN
style.
PXM409S Tri-GripTM
Sanitary Series
®
Standard
74-03
U High 0.08% Accuracy
U Solid State Sensor for Long
Term Stability
U Welded Stainless Steel
Construction
U 316L SS Wetted Parts
U Shock and Vibration Rated
U High Overpressure Rating
U Ruggedized with Secondary
Containment System
U Industrial CE Rating
Dimensions: mm (inch)
Ø = Diameter
ø22.25
(0.88)
5.21 (0.20)
ø50.39
(1.98)
Mating DIN
connector
included
(not shown)
PXM419S15 1½" flange
60.97 (2.40)
PX419S15 1½" flange
1
1
Tri-Grip
or 2"
2
⁄
TM
Fitting
The PXM409S Sanitary Metric
range Series micromachined silicon
transducers with 1½ or 2" sanitary
fittings are ideal for pressure or
level CIP applications in food
processing, beverage, dairy, or bio/
pharmaceutical applications.
They are also rugged enough for
most industrial applications requiring
a high accuracy CIP transducer.
The micromachined silicon sensor
provides a very stabile reading
with exceptional high accuracy of
0.08% and a broad compensated
temperature range of -4 to 85°C
on most ranges. The modular
construction allows for fast delivery
of most configurations and fittings.
Plus, customized models also can
be delivered quickly to suit your
exact needs.
COMMON SPECIFICATIONS
Accuracy: ±0.08% Best Straight
Line (Linearity, Hysteresis and
Repeatability combined) Compound
Gage models calibrated in positive
direction only
Calibration: 5-point NIST
traceable calibration with zero
and span values, calibrated in
horizontal direction
Zero Balance: ±0.5% full scale
typical ±1% maximum (for ranges
≤170 mb ±1% typical ±2%
maximum)
Span Setting: ±0.5% full scale
typical ±1% maximum (for ranges
≤170 mb ±1% typical ±2%
maximum)
PXM419S20-1001BAV, shown
smaller than actual size.
Operating Temperature Range:
-15 to 115°C (-5 to 240°F)
Compensated Temperature
Range:
≤350 mb: 4.4 to 60°C
(40 to 140°F)
>350 mb: -4 to 85°C
(25 to 185°F)
Temperature Compensation
Zero and Span Shift Over
Compensated Range:
≤2 bar: Zero: 1.00%
Span: 0.70%
= 350 mb: Zero: 0.80%
Span: 0.50%
> 350 mb: Zero: 0.50%
Span: 0.50%
550H and 880H Barometric Range:
Zero: 0.90%
Span: 0.50%
Minimum Isolation Between Case
and Output Terminations:
100 M Ω @ 50 Vdc
Pressure Cycles: 1 million,
minimum
Long Term Stability (1-Year):
±0.1% full scale typical
Shock: 50 g, 11 mS half sine shock,
(under test)
Vibration: ±20 g (under test)
Bandwidth: DC to 1 kHz typical
75
Sanitary product line continues to expand,
visit omega.com/sanitary for details!
Response Time: <1 mS
Fill Fluid: NEOBEE M5 Food Grade
Approved to 3A Sanitary
Specification 74-03 CE Compliant:
Meets industrial emissions and
immunity standard IEC61326
Sanitary Pressure Transducers
Gage and Absolute Pressure Ranges
Environmental Protection:
IP65 or IP67 depending upon
electrical termination
Pressure Rating: 1½" and 2"
Tri-Grip™ (compatible the Tri-Clamp®)
Fitting: 40 bar using suitable clamp
Over Pressure: 4 x rated pressure
to maximum rated flange pressure
Secondary Containment: 6 x rated
pressure to a maximum of 138 bar
(not in clamp)
Wetted Parts: 316L SS
Weight: 285 g (10 oz)
10 mV/V Output
11⁄2 or 2" Tri-GripTM Fittings
U
Available
UAll Stainless Steel
Construction
U High Reliability Silicon Sensor
U 3A Approved
10 mV/V
Output
DP25B-S shown smaller
than actual size. Visit
omega.com/dp25b_s
To Order Visit omega.com/pxm409s for Pricing and Details
bar1½" Tri-Grip™ Fitting2" Tri-Grip™ Fitting
Gage Pressure Models, 10 mV/V Output
0 to 25 mbPXM4[*]9S15-025HGVPXM4[*]9S20-025HGV
0 to 70 mbPXM4[*]9S15-070HGVPXM4[*]9S20-070HGV
0 to 170 mbPXM4[*]9S15-170HGVPXM4[*]9S20-170HGV
0 to 350 mbPXM4[*]9S15-350HGVPXM4[*]9S20-350HGV
0-1 barPXM4[*]9S15-001BGVPXM4[*]9S20-001BGV
0 to 2PXM4[*]9S15-002BGVPXM4[*]9S20-002BGV
0 to 3.5PXM4[*]9S15-3.5BGVPXM4[*]9S20-3.5BGV
0 to 7PXM4[*]9S15-007BGVPXM4[*]9S20-007BGV
0 to 10PXM4[*]9S15-010BGVPXM4[*]9S20-010BGV
0 to 17.5PXM4[*]9S15-17.5BGVPXM4[*]9S20-17.5BGV
0 to 35PXM4[*]9S15-035BGVPXM4[*]9S20-035BGV
0 to 40PXM4[*]9S15-040BGVN/A
Absolute Pressure Models, 10 mV/V Output
0 to 350 mbPXM4[*]9S15-350HAVPXM4[*]9S20-350HAV
0 to 1 barPXM4[*]9S15-001BAVPXM4[*]9S20-001BAV
0 to 2PXM4[*]9S15-002BAVPXM4[*]9S20-002BAV
0 to 3.5PXM4[*]9S15-3.5BAVPXM4[*]9S20-3.5BAV
0 to 7PXM4[*]9S15-007BAVPXM4[*]9S20-007BAV
0 to 10PXM4[*]9S15-010BAVPXM4[*]9S20-010BAV
0 to 17.5PXM4[*]9S15-17.5BAVPXM4[*]9S20-17.5BAV
0 to 35PXM4[*]9S15-035BAVPXM4[*]9S20-035BAV
0 to 40PXM4[*]9S15-040BAVN/A
Comes complete with 5-point NIST traceable calibration.
[*] Select electrical termination, no extra charge.
Insert “0” for 2 m (9') cable with flying leads.
For cable with ½ NPT conduit connector order model PXM409CS, no extra charge.
Insert “1” for mini DIN cable (mating connector included).
Insert “5” for M12 connector, M12 cables sold separately (see below).
Custom configurations also available, see omega.com/pxconfigOrdering Examples: PXM409S15-350HGV, 2 m (9') cable termination, 1.5" Tri-Grip fitting,
350 mb range, 10 mV/V output.
PXM419S20-001BAV, mini-DIN connector, 2" Tri-Grip fitting, 0 to 1 bar absolute range,
10 mV/V output.
PXM459S15-007BGI, M12 connector, 1.5" Tri-Grip fitting, 7 bar range, 10 mV/V output.
Shop
online at
SM
To download information and to
order online, visit omega.com/sanitary
76
Sanitary Pressure Transducers
Compound, Vacuum and Barometric Ranges
Specifications
(mV/V Output)
Output: 10 mV/V: Ratiometric
5 to 10 Vdc
Supply: 5 to 10 Vdc
Electrical Terminations
PXM409S: 2 m (6')
cable, IP67 rating
PXM409CS: Conduit/
cable IP67 rating
PXM419S: mini DIN
IP67 rating, absolute
IP65 rating, gage
To Order Visit omega.com/pxm409s for Pricing and Details
Compound Gage Ranges
± 25 mbarPXM4[*]9S15-025HCGVPXM4[*]9S20-025HCGV
± 70 mbarPXM4[*]9S15-070HCGVPXM4[*]9S20-070HCGV
± 170 mbarPXM4[*]9S15-170HCGVPXM4[*]9S20-170HCGV
± 350 mbarPXM4[*]9S15-350HCGVPXM4[*]9S20-350HCGV
Vacuum Ranges (Negative Gage, 0 = Ambient)
0 to -25 mbarPXM4[*]9S15-025HVVPXM4[*]9S20-025HVV
0 to -70 mbarPXM4[*]9S15-070HVVPXM4[*]9S20-070HVV
0 to -170 mbarPXM4[*]9S15-170HVVPXM4[*]9S20-170HVV
0 to -350 mbarPXM4[*]9S15-350HVVPXM4[*]9S20-350HVV
0 to -1 barPXM4[*]9S15-001BVVPXM4[*]9S20-001BVV
Barometric Ranges (Absolute Pressure)
0 to 1100 hPaPXM4[*]9S15-1100HBVPXM4[*]9S20-1100HBV
550 to 1100 hPaPXM4[*]9S15-550HBVPXM4[*]9S20-550HBV
880 to 1100 hPaPXM4[*]9S15-880HBVPXM4[*]9S20-880HBV
Accuracy: ±0.08% BSL (linearity,
hysteresis repeatability combined)
compound gage models calibrated
in positive direction only
Comes complete with 5-point NIST traceable calibration.
[*] Select electrical termination, no extra charge.
Insert “0” for 2 m (9') cable with flying leads.
For ½ NPT conduit connector order model PXM409CS, no extra charge.
Insert “1” for mini DIN cable (mating connector included).
Insert “5” for M12 connector, M12 cables sold separately (see below).
Custom configurations also available, see omega.com/pxconfigOrdering Examples: PXM409S15-170HCGV, cable termination, 1.5" Tri-grip fitting,
± 170 mbar range, 10 mV/V output.
PXM459S20-001BVV, M12 termination, 2" Tri-grip fitting, 0 to -1 bar (vacuum) range,
10 mV/V output.
PXM419S15-550HBV, mini-DIN termination, 1.5" Tri-grip fitting, 550 to 1100 hPa calibrated
barometric range, 10 mV/V output.
visit omega.com/sanitary for details!
PVC cable, straight 4-pin M12 female connector one end,
flying leads one end, 5 m (16.4') long, for PXM459
PVC cable, right angled 4-pin M12 female connector one
end, flying leads one end, 5 m (16.4') long, for PXM459
Sanitary Pressure Transducers
Gages and Absolute Ranges
0 to 10 Vdc Output
11⁄2 or 2" Tri-GripTM Fittings
U
Available
UAll Stainless Steel
Construction
U High Reliability Silicon Sensor
U 3A Approved
DP25B-E shown smaller
than actual size. Visit
omega.com/dp25b
DP41-E shown smaller
than actual size. Visit
omega.com/dp41
0 to 10 Vdc
Output
To Order Visit omega.com/pxm409s for Pricing and Details
bar1½" Tri-Grip™ Fitting2" Tri-Grip™ Fitting
Gage Pressure Models, 0 to 10 Vdc Output
0 to 25 mbPXM4[*]9S15-025HG10VPXM4[*]9S20-025HG10V
0 to 70 mbPXM4[*]9S15-070HG10VPXM4[*]9S20-070HG10V
0 to 170 mbPXM4[*]9S15-170HG10VPXM4[*]9S20-170HG10V
0 to 350 mbPXM4[*]9S15-350HG10VPXM4[*]9S20-350HG10V
0 to 1 barPXM4[*]9S15-001BG10VPXM4[*]9S20-001BG10V
0 to 2PXM4[*]9S15-002BG10VPXM4[*]9S20-002BG10V
0 to 3.5PXM4[*]9S15-3.5BG10VPXM4[*]9S20-3.5BG10V
0 to 7PXM4[*]9S15-007BG10VPXM4[*]9S20-007BG10V
0 to 10PXM4[*]9S15-010BG10VPXM4[*]9S20-010BG10V
0 to 17.5PXM4[*]9S15-17.5BG10VPXM4[*]9S20-17.5BG10V
0 to 35PXM4[*]9S15-035BG10VPXM4[*]9S20-035BG10V
0 to 40PXM4[*]9S15-040BG10VN/A
Absolute Pressure Models, 0 to 10 Vdc Output
0 to 350 mbPXM4[*]9S15-350HA10VPXM4[*]9S20-350HA10V
0 to 1 barPXM4[*]9S15-001BA10VPXM4[*]9S20-001BA10V
0 to 2PXM4[*]9S15-002BA10VPXM4[*]9S20-002BA10V
0 to 3.5PXM4[*]9S15-3.5BA10VPXM4[*]9S20-3.5BA10V
0 to 7PXM4[*]9S15-007BA10VPXM4[*]9S20-007BA10V
0 to 10PXM4[*]9S15-010BA10VPXM4[*]9S20-010BA10V
0 to 17.5PXM4[*]9S15-17.5BA10VPXM4[*]9S20-17.5BA10V
0 to 35PXM4[*]9S15-035BA10VPXM4[*]9S20-035BA10V
0 to 40PXM4[*]9S15-040BA10VN/A
Comes complete with 5-point NIST traceable calibration.
[*] Select electrical termination, no extra charge.
Insert “0” for 2 m (9') cable with flying leads.
For cable with ½ NPT conduit connector order model PXM409CS, no extra charge.
Insert “1” for mini DIN cable (mating connector included).
Insert “5” for M12 connector, M12 cables sold separately (see below).
Custom configurations also available, see omega.com/pxconfigOrdering Examples: PXM409S15-350HG10V, 2 m (9') cable termination, 1.5" Tri-Grip fitting,
350 mb range, 0 to 10 Vdc.
PXM419S20-001BA10V, mini-DIN connector, 2" Tri-Grip fitting, 0 to 1 bar absolute range,
0 to 10 Vdc.
PXM459S15-007BG10V, M12 connector, 1.5" Tri-Grip fitting, 7 bar range, 0 to 10 Vdc.
Shop
online at
SM
To download information and to
order online, visit omega.com/sanitary
78
Sanitary Pressure Transmitters
Compound, Vacuum and Barometric Ranges
Electrical Terminations
PXM409S: 2 m (6')
cable, IP67 rating
PXM409CS: Conduit/
cable IP67 rating
PXM419S: mini DIN
IP67 rating, absolute
IP65 rating, gage
Specifications
(Amplified Voltage Output)
Output/Supply (0 to 10 Vdc):
15 to 30 Vdc
Accuracy: ±0.08% BSL (linearity,
hysteresis repeatability combined)
compound gage models calibrated
in positive direction only
To Order Visit omega.com/pxm409s for Pricing and Details
Comes complete with 5-point NIST traceable calibration.
[*] Select electrical termination, no extra charge.
Insert “0” for 2 m (9') cable with flying leads
For cable with ½ NPT conduit connector order model PXM409CS, no extra charge.
Insert “1” for mini DIN cable (mating connector included).
Insert “5” for M12 connector, M12 cables sold separately (see below).
Custom configurations also available, see omega.com/pxconfigOrdering Examples: PXM409S15-170HCG10V, cable termination, 1.5" Tri-grip fitting,
± 170 mbar range, 0 to 10 Vdc output.
PXM459S20-001BV10V, M12 termination, 2" Tri-grip fitting, 0 to -1 bar (vacuum) range,
0 to 10 Vdc output.
PXM419S15-550HB10V, mini DIN termination, 1.5" Tri-grip fitting, 550 to 1100 hPa calibrated
barometric range, 0 to 10 Vdc output.
visit omega.com/sanitary for details!
PVC cable, straight 4-pin M12 female connector one end,
flying leads one end, 5 m (16.4') long, for PXM459
PVC cable, right angled 4-pin M12 female connector one
end, flying leads one end, 5 m (16.4') long, for PXM459
Sanitary Pressure Transducers
Gages and Absolute Ranges
4 to 20 mA
Output
4 to 20 mA
11⁄2 or 2" Tri-GripTM Fittings
U
Available
UAll Stainless Steel
Construction
U High Reliability Silicon Sensor
U 3A Approved
DP25B-E shown smaller
than actual size. Visit
omega.com/dp25b
To Order Visit omega.com/pxm409s for Pricing and Details
bar1½" Tri-Grip™ Fitting2" Tri-Grip™ Fitting
Gage Pressure Models, 4 to 20 mA Output
0 to 25 mbPXM4[*]9S15-025HGIPXM4[*]9S20-025HGI
0 to 70 mbPXM4[*]9S15-070HGIPXM4[*]9S20-070HGI
0 to 170 mbPXM4[*]9S15-170HGIPXM4[*]9S20-170HGI
0 to 350 mbPXM4[*]9S15-350HGIPXM4[*]9S20-350HGI
0-1 barPXM4[*]9S15-001BGIPXM4[*]9S20-001BGI
0 to 2PXM4[*]9S15-002BGIPXM4[*]9S20-002BGI
0 to 3.5PXM4[*]9S15-3.5BGIPXM4[*]9S20-3.5BGI
0 to 7PXM4[*]9S15-007BGIPXM4[*]9S20-007BGI
0 to 10PXM4[*]9S15-010BGIPXM4[*]9S20-010BGI
0 to 17.5PXM4[*]9S15-17.5BGIPXM4[*]9S20-17.5BGI
0 to 35PXM4[*]9S15-035BGIPXM4[*]9S20-035BGI
0 to 40PXM4[*]9S15-040BGIN/A
Absolute Pressure Models, 4 to 20 mA Output
0 to 350 mbPXM4[*]9S15-350HAIPXM4[*]9S20-350HAI
0-1 barPXM4[*]9S15-001BAIPXM4[*]9S20-001BAI
0 to 2PXM4[*]9S15-002BAIPXM4[*]9S20-002BAI
0 to 3.5PXM4[*]9S15-3.5BAIPXM4[*]9S20-3.5BAI
0 to 7PXM4[*]9S15-007BAIPXM4[*]9S20-007BAI
0 to 10PXM4[*]9S15-010BAIPXM4[*]9S20-010BAI
0 to 17.5PXM4[*]9S15-17.5BAIPXM4[*]9S20-17.5BAI
0 to 35PXM4[*]9S15-035BAIPXM4[*]9S20-035BAI
0 to 40PXM4[*]9S15-040BAIN/A
Comes complete with 5-point NIST traceable calibration.
[*] Select electrical termination, no extra charge.
Insert “0” for 2 m (9') cable with flying leads.
For cable with ½ NPT conduit connector order model PXM409CS, no extra charge
Insert “1” for mini DIN cable (mating connector included)
Insert “5” for M12 connector, M12 cables sold separately (see below)
Custom configurations also available, see omega.com/pxconfigOrdering Examples: PXM409S15-350HGI, 2 m (9') cable termination, 1.5" Tri-Grip fitting,
350 mbar range, 4 to 20 mA output.
PXM419S20-001BAI, mini-DIN connector, 2" Tri-Grip fitting, 0 to 1 bar absolute range,
4 to 20 mA output
PXM459S15-007BGI, M12 connector, 1.5." Tri-Grip fitting, 7 bar range, 4 to 20 mA output.
DP41-E shown smaller
than actual size. Visit
omega.com/dp41
Shop
online at
SM
To download information and to
order online, visit omega.com/sanitary
80
Sanitary Pressure
Transmitters
Compound, Vacuum and
Barometric Ranges
Electrical Terminations
PXM409S: 2 m (6')
cable, IP67 rating
PXM409CS: Conduit/
cable IP67 rating
PXM419S: mini DIN
IP67 rating, absolute
IP65 rating, gage
4 to 20 mAdc
Output
Specifications)
Output: 4 to 20 mAdc
Supply: 9 to 30 Vdc
9 to 20 Vdc above 105°C (229°F)
max loop res Ω = (Vs-9) x 50
To Order Visit omega.com/pxm409s for Pricing and Details
Compound Gage Ranges
Vacuum Ranges (Negative Gage, 0 = Ambient)
Barometric Ranges (Absolute Pressure)
550 to 1100 hPaPXM4[*]9S15-550HBIPXM4[*]9S20-550HBI
880 to 1100 hPaPXM4[*]9S15-880HBIPXM4[*]9S20-880HBI
Accuracy: ±0.08% BSL (linearity,
hysteresis repeatability combined)
compound gage models calibrated
in positive direction only
Range
mbar
± 25 mbarPXM4[*]9S15-025HCGIPXM4[*]9S20-025HCGI
± 70 mbarPXM4[*]9S15-070HCGIPXM4[*]9S20-070HCGI
± 170 mbarPXM4[*]9S15-170HCGIPXM4[*]9S20-170HCGI
± 350 mbarPXM4[*]9S15-350HCGIPXM4[*]9S20-350HCGI
± 1 barPXM4[*]9S15-001BCGIPXM4[*]9S20-001BCGI
0 to -25 mbarPXM4[*]9S15-025HVIPXM4[*]9S20-025HVI
0 to -70 mbarPXM4[*]9S15-070HVIPXM4[*]9S20-070HVI
0 to -170 mbarPXM4[*]9S15-170HVIPXM4[*]9S20-170HVI
0 to -350 mbarPXM4[*]9S15-350HVIPXM4[*]9S20-350HVI
0 to -1 barPXM4[*]9S15-001BVIPXM4[*]9S20-001BVI
0 to 1100 hPaPXM4[*]9S15-1100HBIPXM4[*]9S20-1100HBI
Comes complete with 5-point NIST traceable calibration.
[*] Select electrical termination, no extra charge.
Insert “0” for 2 m (9') cable with flying leads.
For cable with ½ NPT conduit connector order model PXM409CS, no extra charge.
Insert “1” for mini DIN cable (mating connector included).
Insert “5” for M12 connector, M12 cables sold separately.
Custom configurations also available, see omega.com/pxconfigOrdering Examples: PXM409S15-170HCGI, cable termination, 1.5" Tri-grip fitting,
± 170 mbar range, 4 to 20 mA output.
PXM459S20-001BVI, M12 termination, 2" Tri-grip fitting, 0 to -1 bar (vacuum) range,
4 to 20 mA output.
PXM419S15-550HBI, mini DIN termination, 1.5" Tri-grip fitting, 550 to 1100 hPa calibrated
barometric range, 4 to 20 mA output.
visit omega.com/sanitary for details!
PVC cable, straight 4-pin M12 female connector one end,
flying leads one end, 5 m (16.4') long, for PXM459
PVC cable, right angled 4-pin M12 female connector one
end, flying leads one end, 5 m (16.4') long, for PXM459
High Accuracy Pressure Transducers
Conduit backend PX409C
Integral cable backend PX409
Twist-lock backend PX429
5 (0.2)
5 (0.2)
28
(1.1)
½ NPT TH’D
Vent with porous plug(gage units only)
(gage units only)
Piezoresistive Design With High Temperature Performance
All images shown
smaller than actual size.
Cable style.
PXM409S Series
PXM409S Cable Connection
Color mV 5/10V mA
Black – EXC Common – Supply
White + SIG + Output NC
Green – SIG NC NC
Red+ EXC + EXC + Supply
Conduit backend PXM409C
Conduit backend PX409C
28
(1.1)
Integral cable backend PXM409S
Integral cable backend PX409
5 (0.2)
½ NPT TH’D
mini DIN and M12 style.
PXM419S/PXM459S Pinout
Pin mV 5/10V mA
1+ EXC + EXC + Supply
2– EXC Common – Supply
3+ SIG + Output NC
4– SIG NC NC
mini DIN backend PXM419S
mini DIN backend PX419
5 (0.2)
Vent with porous plug
PXM419S Series
PXM459S M12
connector.
NC = No Connection.
Dimensions: mm (inch)
M12 connector
2 connector
backend PXM459S
bacend
Ø 20.2
(0.8)
2
(0.2)
Compatible Meters and Accessories
Meters
Model No. Description
DP41-S 6-digit high accuracy (0.005%) process meter for use with milli voltage and strain gage bridge
DP41-E
DP25B-E 4-digit precision process meter for use with voltage and current output models
Accessories
CX5302 Extra mini DIN connector for PXM419S Series
M12C-PVC-4-S-F-5 PVC cable, straight 4-pin M12 female connector one end, flying leads one end, 5 m (16.4’) long,
M12C-PVC-4-R-F-5 PVC cable, right angled 4-pin M12 female connector one end, flying leads one end 5 m (16.4’) long,
6-digit high accuracy (0.005%) meter for use with voltage and current output models
Shop
online at
output models
for PXM459S
for PXM459S
SM
To download information and to
order online, visit omega.com/sanitary
82
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.