4 to 20 mA Output/SMART
0-1 to 0-4000 psi
0-0.07 to 0-275 bar
All Ranges
$
1255
⻬ HART®-Protocol Ready
⻬ 20:1 Turndown
⻬ External Zero and Span
⻬ 0.20% Accuracy
⻬ Security Jumpers
⻬ Polysilicon Sensor
Ensures High Stability
and Reliability
⻬ Dual-Compartment
Housing (Watertight
Electronics Compartment)
⻬ Individually
Characterized and
Digitally Compensated
⻬ RFI Protection
Selected Options
⻬ Stainless Steel or
Hastelloy
®
Wetted Parts
⻬ Silicon or Inert Oil Fill
⻬ LCD Meter Option
⻬ Integral Manifolds,
Preassembled and
Leak Tested
Recommended Reference Book:
Environmental Remote Sensing
ES-1019, $205.
Visit omega.com/bobi
for Additional Books
,
PX2088S-30GI
analog transducer,
$1255, shown smaller
than actual size.
OMEGA’s PX2088S Series smart
pressure transmitters maintain a
specification conformance of at least
3. The reliable performance of these
rugged transmitters, when coupled
with the broad selection of options,
makes these transducers an
exceptional value for tough process
applications.The PX2088S is
designed to operate safely in the
event of damage or failure to the
sensor diaphragm. The electronics
compartment is isolated from the
process by 2 seals.
A third seal isolates the field
terminals and conduit entries.
This design ensures against
housing pressurization and
process contamination.
The electronics incorporates an
ASIC module that accepts the digital
signal from the sensor, along with the
correction coefficients, then corrects
and linearizes the signal. This is then
converted to an analog signal for
retransmission. The output section
also handles the HART
communications.
®
AVAILABLE FOR FAST DELIVERY!
To Order (Specify Model Number)
MODEL NO.PRICE MIN SPAN MAX SPAN COMPATIBLE METERS*
SMART 4 to 20 mA Output
PX2088S-30GI$1255 0 to 1.5 psi0 to 30 psiDP41-E, DP25B-E, DP24-E
PX2088S-150GI12550 to 7.50 to 150DP41-E, DP25B-E, DP24-E
PX2088S-600GI12550 to 300 to 600DP41-E, DP25B-E, DP24-E
PX2088S-4KGI12550 to 2000 to 4000DP41-E, DP25B-E, DP24-E
Comes with complete operator’s manual.
See section D for compatible meters.
*
See Specifications for fitting material and fill fluid options.
To order absolute pressure ranges, change the “G” in the model number to an “A”, and add
$215 to price. To order LCD meter scaled 0 to 100%, add suffix “-M5”, and add $250 to price.
Ordering Example: PX2088S-150AI, smart transducer, 150 psi absolute pressure range,
with 4 to 20 mA output, $1255 + 215 = $1470.
B-175
Page 2
SMART OR ANALOG INDUSTRIAL TRANSMITTER
Transmitter
Circuitry
Optional
Meter Cover
125 (5.0)
110 (4.3)
Max.
20 (0.75)
Clearance
for Cover
Removal
2 x ½ - 14 NPT*
Conduit
Connection
Terminal
Connections
®
OMEGA
100 (3.9)
Certifications
Tag
120
(4.7)
140
(5.4)
Typical
½ - 14 NPT
Female
†
Process
Connection
2 x ¼ - 20
UNC - 2B
Mounting
Holes
OMEGA
®
140
(5.0)
90
(3.5)
63
(2.5)
32 (1.25)
HEX
150 (6.0)
125 (5.0)
110 (4.3)
Max.
80 (3.0)
2-inch U-Bolt
for Pipe Mounting
SMART FUNCTIONALITY
The PX2088S smart transducer
HART®protocol allows easy access
to configuration, test, and setup
capabilities.
The PX2088S can be configured
using a HART
or another HART®-based
communications device.
Configuration consists of
two steps. First, the transmitter
operational parameters are set
including:
– Zero and span
– Damping
– Engineering units.
Second, data can be entered into the
transmitter to allow identification and
physical description of the
transmitter. These data include:
– Tag: 8 alphanumerics
– Descriptor: 16 characters
– Message: 32 characters
– Date
– Integral meter installation
– Remote seal information
In addition to the configurable
parameters, the PX2088 software
contains information that is not userchangeable. Non-configurable
information includes:
– Transmitter type
– Sensor limits
– Minimum span
®
communicator
– Fill fluid
– Isolator material
– Module serial number
Transmitter software revision level
–
SPECIFICATIONS
Excitation: 10.5 to 36 Vdc unregulated,
reverse polarity protected
Supply Effect: <0.01% span/V
Zero Elevation and Suppression:
Zero can be suppressed between
atmosphere (or 0 psia for absolute
ranges) and the upper range limit
(URL), provided the span is ≥ the
minimum span and the URL does not
exceed the unit’s URL. No vacuum
calibrations are allowed on the gage
pressure models.
Calibrators, Connectors, General Test and Measurement
Instruments, Glass Bulb Thermometers, Handheld Instruments
for Temperature Measurement, Ice Point References,
Indicating Labels, Crayons, Cements and Lacquers, Infrared
Temperature Measurement Instruments, Recorders Relative
Humidity Measurement Instruments, RTD Probes, Elements
and Assemblies, Temperature & Process Meters, Timers and
Counters, Temperature and Process Controllers and Power
Switching Devices, Thermistor Elements, Probes and
Assemblies,Thermocouples Thermowells and Head and Well
Assemblies, Transmitters, Wire
Flow and Level
Air Velocity Indicators, Doppler Flowmeters, Level
Measurement, Magnetic Flowmeters, Mass Flowmeters,
Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel
Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area
Flowmeters, Vortex Shedding Flowmeters
pH and Conductivity
Conductivity Instrumentation, Dissolved Oxygen
Instrumentation, Environmental Instrumentation, pH
Electrodes and Instruments, Water and Soil Analysis
Instrumentation
Data Acquisition
Auto-Dialers and Alarm Monitoring Systems,
Communication Products and Converters, Data
Acquisition and Analysis Software, Data Loggers
Plug-in Cards, Signal Conditioners, USB, RS232, RS485
and Parallel Port Data Acquisition Systems, Wireless
Transmitters and Receivers
Band Heaters, Cartridge Heaters, Circulation Heaters,
Comfort Heaters, Controllers, Meters and Switching
Devices, Flexible Heaters, General Test and Measurement
Instruments, Heater Hook-up Wire, Heating Cable
Systems, Immersion Heaters, Process Air and Duct,
Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
click here to go to the omega.com home page
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.